An Implantable Wireless System for Remote Hemodynamic Monitoring of Heart Failure Patients

被引:2
|
作者
Besirli, Mustafa [1 ]
Ture, Kerim [1 ]
Beghetti, Maurice
Maloberti, Franco [2 ,3 ]
Dehollain, Catherine [1 ]
Mattavelli, Marco [1 ]
Barrettino, Diego [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Elect & Micro Engn, CH-1015 Lausanne, Switzerland
[2] Geneva Univ Hosp HUG, Pediat Cardiol Unit, CH-1205 Geneva, Switzerland
[3] Univ Pavia, Dept Elect Comp & Biomed Engn, I-27100 Pavia, Italy
基金
瑞士国家科学基金会;
关键词
ASIC; CMOS; energy-efficient; hemodynamic monitoring; heart failure; implantable medical devices; inductive sensor; pressure sensor; remote patient monitoring; readout IC; ultrasonic powering; ultrasonic communication; LOW-DROPOUT REGULATOR; POWER TRANSFER; DISEASE; BURDEN; LINK;
D O I
10.1109/TBCAS.2023.3273711
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article presents an implantable wireless system for remote hemodynamic monitoring, which enables direct, continuous (24/7), and simultaneous measurement of pulmonary arterial pressure (PAP) and cross-sectional area (CSA) of the artery. The implantable device, which measures 3.2 mm x 2 mm x 10 mm, comprises a piezoresistive pressure sensor, an ASIC implemented in 180-nm CMOS, a piezoelectric ultrasound (US) transducer, and a nitinol anchoring loop. An energy-efficient pressure monitoring system, which employs duty-cycling and spinning excitation technique, achieves 0.44 mmHg resolution in a pressure range from -135 mmHg to +135 mmHg and consumes 1.1 nJ conversion energy. The artery diameter monitoring system utilizes the inductive characteristic of the implant's anchoring loop and achieves 0.24 mm resolution within a diameter range of 20 mm to 30 mm, four times higher than echocardiography lateral resolution. The wireless US power and data platform enables simultaneous power and data transfer employing a single piezoelectric transducer in the implant. The system is characterized with an 8.5 cm tissue phantom and achieves a US link efficiency of 1.8%. The uplink data is transmitted by using an ASK modulation scheme parallel to the power transfer and achieves a modulation index of 26%. The implantable system is tested in an in-vitro experimental setup, which emulates the arterial blood flow, and accurately detects fast pressure peaks for systolic and diastolic pressure changes at both 1.28 MHz and 1.6 MHz US powering frequencies, with corresponding uplink data rates of 40 kbps and 50 kbps.
引用
收藏
页码:688 / 700
页数:13
相关论文
共 50 条
  • [1] Implantable Hemodynamic Monitoring for Heart Failure Patients
    Abraham, William T.
    Perl, Leor
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (03) : 389 - 398
  • [2] Wireless Hemodynamic Monitoring in Patients with Heart Failure
    Lander, Matthew M.
    Aldweib, Nael
    Abraham, William T.
    [J]. CURRENT HEART FAILURE REPORTS, 2021, 18 (01) : 12 - 22
  • [3] Wireless Hemodynamic Monitoring in Patients with Heart Failure
    Matthew M. Lander
    Nael Aldweib
    William T. Abraham
    [J]. Current Heart Failure Reports, 2021, 18 : 12 - 22
  • [4] Implantable hemodynamic monitoring devices in heart failure
    Pamboukian S.V.
    Smallfield M.C.
    Bourge R.C.
    [J]. Current Cardiology Reports, 2006, 8 (3) : 187 - 190
  • [5] Benefits of remote hemodynamic monitoring in heart failure
    Clephas, P. R. D.
    de Boer, R. A.
    Brugts, J. J.
    [J]. TRENDS IN CARDIOVASCULAR MEDICINE, 2024, 34 (07) : 468 - 476
  • [6] CardioMEMS™: a tool for remote hemodynamic monitoring of chronic heart failure patients
    Radhoe, Sumant P.
    Brugts, Jasper J.
    [J]. FUTURE CARDIOLOGY, 2021, 18 (03) : 173 - 183
  • [7] Long-term effects of implantable hemodynamic monitoring in patients with moderate heart failure
    Raval, N.
    Abraham, W.
    Adamson, P.
    Chronos, N.
    Sachar, R.
    Ginn, G.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 298 - 298
  • [8] Association of Echocardiographic Parameters and Outcomes in Patients with Heart Failure with Reduced Ejection Fraction who Have an Implantable Remote Pulmonary Artery Hemodynamic Monitoring System
    Gowda, Smitha Narayana
    Abdullah, Ammar
    Sharma, Rakshya
    Oberoi, Mansi
    DeHaan, Max
    Roman Pham
    Orvarsson, Jon
    Blue, Mason
    Stys, Adam
    Stys, Tom
    Petrasko, Marian
    Rajpurohit, Naveen
    Jonsson, Orvar
    [J]. JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : S158 - S158
  • [9] Impact of Remote Pulmonary Artery Hemodynamic Monitoring System in Reducing Heart Failure Readmissions Among Patients with Heart Failure and Atrial Fibrillation
    Gowda, Smitha Narayana
    Orvarsson, Jon
    Blue, Mason
    Pham, Roman
    Singh, Aditya
    Abdullah, Ammar
    Sharma, Rakshya
    Oberoi, Mansi
    Stys, Adam
    Stys, Tom
    Petrasko, Marian
    Rajpurohit, Naveen
    Bares, Valerie
    Jonsson, Orvar
    [J]. JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : S156 - S156
  • [10] The Utility of a Wireless Implantable Hemodynamic Monitoring System in Patients Requiring Mechanical Circulatory Support
    Feldman, David S.
    Moazami, Nader
    Adamson, Philip B.
    Vierecke, Juliane
    Raval, Nir
    Shreenivas, Satya
    Cabuay, Barry M.
    Jimenez, Javier
    Abraham, William T.
    O'Connell, John B.
    Naka, Yoshifumi
    [J]. ASAIO JOURNAL, 2018, 64 (03) : 301 - 308