A Study on the Application of Lateral Earth Pressure to Earth Retaining Wall Considering Ground Characteristics in Jeju II- Case of Earth Anchor Construction

被引:0
|
作者
Kim, Do-Hyeong [1 ]
Lee, Dong-Wook [1 ]
Kim, Seung-Hyun [2 ]
Ko, Kwon-Moon [3 ]
机构
[1] Jeju Natl Univ, Dept Civil Engn, 102 Jejudaehak Ro, Jeju 63243, South Korea
[2] Jeju Special Selfgoverning Prov Council, 13 Munyeon Ro, Jeju 63119, South Korea
[3] Korea Rual Community Corp Jeju Reg Heafquarter, 12 Seonsa Ro, Jeju 63318, South Korea
来源
关键词
Lateral earth pressure; Clinker layer; Earth retaining wall; Earth anchor; Jeju island;
D O I
10.12814/jkgss.2023.22.2.085
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper describes the comparative results of measured and predicted values for the horizontal displacement of earth retaining wall based on two field cases, in order to evaluate the application of lateral earth pressure to earth retaining wall supported by earth anchor in Jeju. The prediction of lateral earth pressure acting on the earth retaining wall was performed by elasto-plastic analysis using Rankine earth pressure, Hong & Yun lateral earth pressure, Terzaghi & Peck modified lateral earth pressure, and Tschebotarioff lateral earth pressure. As a result, the predicted value of the maximum horizontal displacement for site A was about 10 to 12 times greater than the measured value, and in the case of site B, the predicted value was evaluated as about 9 to 12 times greater than the measured value. That is, both sites showed a similar increase rate in the maximum horizontal displacement by the predicted value compared to the measured value. In all field construction cases, the maximum horizontal displacement by measured values occurred in the sedimentary layer, soft rock layer, and clinker layer, and the horizontal displacement distribution was shown in a trapezoidal shape. The maximum horizontal displacement by the predicted value occurred around the clinker layer, and the horizontal displacement distribution was elliptical. In the ground with a clinker layer, the measured value showed a very different horizontal displacement tendency from the predicted value, because the clinker layer exists in the form of a rock layer and continuous layer. In other words, it is unreasonable to apply the existing prediction method, which is overestimated, because the characteristics of the earth pressure distribution in Jeju show a tendency to be quite different from the predicted earth pressure distribution. Therefore, it is necessary to conduct a research on the lateral earth pressure in the realistic Jeju that can secure more economic efficiency.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 50 条
  • [1] A Study on the Application of Lateral Earth Pressure to Earth Retaining Wall Considering Ground Characteristics in Jeju I- Case of Strut Construction
    Kim, Do-Hyeong
    Lee, Dong-Wook
    Choi, Hee-Bok
    Ko, Kwon-Moon
    JOURNAL OF THE KOREAN GEOSYNTHETIC SOCIETY, 2023, 22 (02): : 55 - 61
  • [2] Lateral Earth Pressure Considering the Displacement of a Rigid Retaining Wall
    Tang, Yao
    Li, Jing Pei
    Ma, Yuan
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2018, 18 (11)
  • [3] Active earth pressure on a retaining wall and lateral coefficient of earth pressure
    Wang Yuan-zhan
    Li Xin-guo
    Chen Nan-nan
    ROCK AND SOIL MECHANICS, 2005, 26 (07) : 1019 - 1022
  • [4] Study on Lateral Earth Pressure of Anchored Retaining Wall
    Li, Yingyong
    Zheng, Lizhi
    Zhang, Hongbo
    Song, Xiuguang
    Xue, Zhichao
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 312 - 317
  • [5] LATERAL EARTH PRESSURE ON RETAINING STRUCTURE WITH ANCHOR PLATES
    HUA, ZK
    SHEN, CK
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1987, 113 (03): : 189 - 201
  • [6] The Study on Earth Pressure against Retaining Wall Considering Displacement
    Kuai, Haidong
    Li, Wei
    Zhang, Kunyong
    Ai, Yingbo
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS SCIENCE AND CIVIL ENGINEERING (AMSCE 2017), 2017, 70 : 171 - 174
  • [7] LATERAL EARTH PRESSURE ON RETAINING STRUCTURE WITH ANCHOR PLATES.
    Hua, Zu-Kun
    Shen, C.K.
    Journal of geotechnical engineering, 1987, 113 (03): : 189 - 201
  • [8] LATERAL EARTH PRESSURE ON RETAINING STRUCTURE WITH ANCHOR PLATES - DISCUSSION
    CHUGH, AK
    SMART, JD
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1989, 115 (03): : 423 - 424
  • [9] Active earth pressure of retaining wall considering wall movement
    Chen, Lin
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2014, 18 (08) : 910 - 926