LOW-COST CALIBRATION METHOD FOR THE INFRARED CAMERA

被引:0
|
作者
Uemura, Derek Koji [1 ]
Shah, Sanjay B. [2 ]
Regmi, Prafulla [3 ]
Grimes, Jesse [4 ]
Wang-Li, Lingjuan [2 ]
机构
[1] Nelson Irrigat Corp, Walla Walla, WA 99362 USA
[2] North Carolina State Univ, Biol & Agr Engn, Raleigh, NC 27695 USA
[3] Univ Georgia, Poultry Sci, Athens, GA USA
[4] North Carolina State Univ, Prestage Dept Poultry Sci, Raleigh, NC USA
关键词
Absolute error; Accuracy; Emissivity; Heat stress; IR; Precision; Reflected air temperature; Sensitivity analysis; THERMOGRAPHY;
D O I
10.13031/aea.15546
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Infrared (IR) or thermal cameras are being increasingly used in livestock research and management. An IR camera's accuracy is specified over its entire surface temperature measurement range, whereas in livestock research and management, a narrower range suffices. A camera's accuracy could be higher in a narrower range of temperatures. Hence, a novel low-cost method was used to calculate the FLIR E8 camera's accuracy in a range of 24 degrees C to 37 degrees C, representative of surface temperature of poultry birds. Sensitivity analyses were also performed to evaluate the impact of three user spec-ified parameters, namely, emissivity (epsilon), distance between camera and surface (d), and reflected air temperature (tair). A linear regression model was used to correct the camera's absolute error of 2.8 degrees C (greater than its published error). How-ever, the camera possessed precision and hence, repeatability. The IR camera was moderately sensitive to epsilon, and slightly sensitive to tair and d, but its error could increase with the difference between the measured and assumed tair values. Attention is required to accurately characterize epsilon and tair. This simple calibration method can reduce cost and could improve accuracy in a narrower temperature range than the IR camera's published range, which could be useful for applied research.
引用
收藏
页码:529 / 534
页数:6
相关论文
共 50 条
  • [1] An efficient low-cost calibration board for Long-wave infrared (LWIR) camera
    Swamidoss, Issac Niwas
    Bin Amro, Amani
    Sayadi, Slim
    [J]. ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS XVII, 2020, 11537
  • [2] Novel low-cost uncooled infrared camera
    Wu, M
    Cook, J
    DeVito, R
    Li, J
    Ma, E
    Murano, R
    Nemchuk, N
    Tabasky, M
    Wagner, M
    [J]. Infrared Technology and Applications XXXI, Pts 1 and 2, 2005, 5783 : 496 - 505
  • [3] A LOW-COST CALIBRATION METHOD FOR AUTOMATED OPTICAL MENSURATION USING A VIDEO CAMERA
    WANG, CC
    [J]. MACHINE VISION AND APPLICATIONS, 1994, 7 (04) : 259 - 266
  • [4] On Calibration of a Low-Cost Time-of-Flight Camera
    Kuznetsova, Alina
    Rosenhahn, Bodo
    [J]. COMPUTER VISION - ECCV 2014 WORKSHOPS, PT I, 2015, 8925 : 415 - 427
  • [5] A Method of A Method of Low-Cost IMU Calibration and Alignment
    Lv, Jixin
    Ravankar, Ankit A.
    Kobayashi, Yukinori
    Emaru, Takanori
    [J]. 2016 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2016, : 373 - 378
  • [6] Calibration method enabling low-cost SDR
    Debaillie, Bjoern
    Van Wesemael, Peter
    Craninckx, Jan
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, PROCEEDINGS, VOLS 1-13, 2008, : 4899 - 4903
  • [7] A low-cost calibration method for the infrared sensor array for quantitative analysis of natural gas
    Wang, Jinlei
    Lei, Bingjie
    Yang, Zaiyun
    Lei, Shaochong
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2022, 230
  • [8] Machine vision applications of low-cost thermal infrared camera
    Rigney, MP
    Franke, EA
    [J]. THERMOSENSE XXII, 2000, 4020 : 15 - 26
  • [9] Low-cost far infrared bolometer camera for automotive use
    Vieider, Christian
    Wissmar, Stanley
    Ericsson, Per
    Halldin, Urban
    Niklaus, Frank
    Stemme, Goeran
    Kallhammer, Jan-Erik
    Pettersson, Hakan
    Eriksson, Dick
    Jakobsen, Henrik
    Kvisteroy, Terje
    Franks, John
    VanNylen, Jan
    Vercammen, Hans
    VanHulsel, Annick
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXXIII, 2007, 6542
  • [10] Validation of a Low-cost Camera for Scalable HeliOstat calibRation sysTem (SHORT)
    Les, Inigo
    Pena-Lapuente, Adrian
    Sanchez, Marcelino
    Olasolo, David
    Villasante, Cristobal
    Enrique, Raul
    Fernandez-Reche, Jesus
    [J]. SOLARPACES 2020 - 26TH INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2022, 2445