Development of Conducting Biopolymer-Based Biosensor for Heavy-Metal Ion Detection

被引:1
|
作者
Dutta, Shreya [1 ]
Butola, Ravi [2 ]
Singh, Bhupendra Pratap [3 ]
Chandra, Prakash [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Delhi 110042, India
[2] GGSIP Univ, Univ Sch Automat & Robot USAR, East Delhi Campus, Delhi 110092, India
[3] Cent Univ Haryana, Dept Environm Studies, Mahendergarh 123031, Haryana, India
关键词
CONDUCTOMETRIC BIOSENSOR; COMPOSITE; ELECTRODE; VOLTAMMETRY; FABRICATION; POLYMERS; UREASE;
D O I
10.1149/2162-8777/ad041d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The increasing concentration of heavy metals in the water ecosystems has been a noteworthy concern nowadays. This has accounted for various diseases, due to the bioaccumulation in the human body. We propose a biocompatible, non-toxic technique for the identification of heavy metal ions from the contaminated aquatic samples. A urease biosensor, having interpenetrating network of Katira-cl-Acrylic Acid (AAc)/Polyaniline (PANI) hydrogel composite deposited onto the indium tin oxide (ITO). Enhanced hydrogel conductivity due to the incorporation of PANI has been gained by the interfacial polymerization of katira gum and aniline monomer in the ratio of 2:1 using N,N'-MBA and APS as cross-linker and initiator respectively. Structural, morphological and electrochemical characterization of PANI/ITO, Katira-cl-AAc/PANI/ITO and Urease/Katira-cl-AAc/PANI/ITO electrode conducted using SEM, FT-IR, TGA, UV spectrometry, cyclic voltammetry. A comparative study of different concentrations of cadmium, cobalt and Mercury, has been done. The inhibition rates were found to be in the order of Hg2+ > Cd2+ > Co2+. Enzyme inhibition observed in the concentration range from 1.8 mM to 5 mM, 0.1 mM to 2 mM and 0.1 mM to 5 mM respectively. Urease/Katira-cl-AAc/PANI/ITO, exhibits greater stability, enhanced sensitivity and wide-range of detection limit (200 to 270 ng l(-1)) with a shelf life.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] MERCURY(II) THIOLATE CHEMISTRY AND THE MECHANISM OF THE HEAVY-METAL BIOSENSOR MERR
    WRIGHT, JG
    NATAN, MJ
    MACDONNELL, FM
    RALSTON, DM
    OHALLORAN, TV
    PROGRESS IN INORGANIC CHEMISTRY, 1990, 38 : 323 - 412
  • [32] Polydopamine nanospheres: A biopolymer-based fluorescent sensing platform for DNA detection
    Liu, Qian
    Pu, Zonghua
    Asiri, Abdullah M.
    Al-Youbi, Abdulrahman O.
    Sun, Xuping
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 567 - 571
  • [33] Development of conducting paper-based electrochemical biosensor for procalcitonin detection
    Gupta, Yachana
    Ghrera, Aditya Sharma
    ADMET AND DMPK, 2023, 11 (02): : 263 - 275
  • [34] HEAVY-METAL ION INTERACTIONS WITH SERUM-LIPOPROTEINS
    MALINS, DC
    REICHERT, WL
    FEDERATION PROCEEDINGS, 1973, 32 (03) : 548 - &
  • [35] TRACE ANALYSIS OF HEAVY-METAL IONS BY ION CHROMATOGRAPHY
    BAUER, H
    OTTENLINGER, D
    YAN, D
    CHROMATOGRAPHIA, 1989, 28 (5-6) : 315 - 317
  • [36] HEAVY-METAL ION ADSORBENTS HAVING THIOAMIDE GROUPS
    KAERIYAMA, K
    JOURNAL OF APPLIED POLYMER SCIENCE, 1979, 24 (05) : 1205 - 1213
  • [37] HEAVY-METAL ION SEPARATION BY FUNCTIONAL POLYMERIC MEMBRANES
    HAYASHITA, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 16 - IEC
  • [38] HEAVY-METAL ION NUCLEIC-ACID INTERACTION
    KIM, SH
    SHIN, WC
    WARRANT, RW
    METHODS IN ENZYMOLOGY, 1985, 114 : 156 - 167
  • [39] HEAVY-METAL ION SCAVENGERS FROM CYANURIC CHLORIDE
    KAERIYAMA, K
    ROKUSHA, T
    NAOMI, K
    JOURNAL OF APPLIED POLYMER SCIENCE, 1978, 22 (11) : 3075 - 3080
  • [40] Investigation of regeneratable biopolymer-based aerogels for heavy metal decontamination from water: Quantum chemical analysis and experimental investigation
    Syeda, Hina Iqbal
    Muthukumaran, Shobha
    Baskaran, Kanagaratnam
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 353