Dimensional Stability of Light-Activated Urethane Dimethacrylate Denture Base Resins

被引:5
|
作者
Mishra, Swati [1 ]
Chaturvedi, Saurabh [2 ]
Ali, Mariyam [1 ]
Pandey, Kaushik Kumar [1 ]
Alqahtani, Nasser M. [2 ]
Alfarsi, Mohammed A. [2 ]
Addas, Mohamed Khaled [2 ]
Vaddamanu, Sunil Kumar [3 ]
Al Ahmari, Nasser M. [2 ]
Alqahtani, Saeed M. [2 ]
Yaqoob, Ashfaq [2 ]
Alqahtani, Waleed M. S. [2 ]
机构
[1] Career Postgrad Inst Dent Sci, Dept Prosthodont, Lucknow 226008, India
[2] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha 61421, Saudi Arabia
[3] King Khalid Univ, Coll Appl Med Sci, Dept Dent Technol, Abha 61421, Saudi Arabia
关键词
UDMA; record base; light cure denture base; dimensional discrepancy; POLYMERIZATION; STRENGTH; ACCURACY; REPAIR;
D O I
10.3390/polym15030744
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Physical properties of modified urethane dimethacrylate denture base resins.
    Latta, MA
    vonFraunhofer, JA
    Thompson, VP
    Blank, LW
    Barnes, DM
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2618 - 2618
  • [2] IMPLANT DENTURE MODIFICATION WITH LIGHT-ACTIVATED DENTURE RESIN
    DEBOER, J
    VERHOEF, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06): : 984 - 985
  • [3] AN EXPERIMENTAL-STUDY ON DIMENSIONAL STABILITY OF COMPLETE DENTURE PROCESSED IN VARIOUS DENTURE BASE RESINS
    YUN, SD
    KIM, CW
    [J]. JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 687 - 687
  • [4] VISIBLE LIGHT-ACTIVATED RESINS - DEPTH OF CURE
    SWARTZ, ML
    PHILLIPS, RW
    RHODES, B
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1983, 106 (05): : 634 - 637
  • [5] SUPERFICIAL SET OF LIGHT-ACTIVATED COMPOSITE RESINS
    STOKES, AN
    [J]. JOURNAL OF DENTAL RESEARCH, 1983, 62 (04) : 405 - 405
  • [6] THE LOSS OF RESIDUAL MONOMER FROM DENTURE BASE POLYMERS COATED WITH AN ULTRAVIOLET LIGHT-ACTIVATED POLYMER
    SZABO, G
    STAFFORD, GD
    HUGGETT, R
    BROOKS, SC
    [J]. DENTAL MATERIALS, 1987, 3 (02) : 64 - 66
  • [7] ULTRAVIOLET-LIGHT AND ULTRAVIOLET LIGHT-ACTIVATED COMPOSITE RESINS
    MURRAY, GA
    YATES, JL
    NEWMAN, SM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1981, 46 (02): : 167 - 170
  • [8] DENTURE BASE RESINS - COMPARISON STUDY OF COLOR STABILITY
    MAY, KB
    RAZZOOG, ME
    KORAN, A
    ROBINSON, E
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01): : 78 - 82
  • [9] BOND STRENGTH AND HARDNESS OF LIGHT-ACTIVATED COMPOSITE RESINS
    SCHULEIN, TM
    BOYER, DB
    CHALKLEY, Y
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (07): : 789 - 796
  • [10] CURING LIGHT-ACTIVATED COMPOSITE RESINS THROUGH DENTIN
    CHAN, KC
    BOYER, DB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (05): : 643 - 645