Near-Infrared Spectroscopy measurements are reliable for studying patellar bone hemodynamics and affected by venous occlusion, but not by skin compression

被引:1
|
作者
Ophey, Martin J. [1 ,2 ,3 ]
Westerweel, Anne [4 ]
van Oort, Maxime [4 ]
van den Berg, Robert [3 ,5 ,6 ]
Kerkhoffs, Gino M. M. J. [2 ,7 ,8 ]
Tak, Igor J. R. [3 ,7 ,8 ,9 ]
机构
[1] IJsveldFysio Private Phys Therapy Clin, Nijmegen, Netherlands
[2] Locat Univ Amsterdam, Amsterdam UMC, Dept Orthopaed Surg & Sports Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] ESP Sci & Educ, Vienna, Austria
[4] RU Radboud Univ, Biomed Sci, Nijmegen, Netherlands
[5] Univ Appl Sci, FH Burgenland, Phys Therapy Dept, Pinkafeld, Austria
[6] AIM Austrian Inst Management, Adv Physiotherapy & Management, Eisenstadt, Austria
[7] Amsterdam Collaborat Hlth & Safety Sports ACHSS, IOC Res Ctr, Amsterdam, Netherlands
[8] Acad Ctr Evidence Based Sports Med ACES, Amsterdam, Netherlands
[9] Sports Rehabil & Manual Therapy, Physiotherapy Utrecht Oost, Utrecht, Netherlands
关键词
Patellofemoral pain; Reliability; Near-Infrared Spectroscopy; SYMPTOMATIC PATELLOFEMORAL MALALIGNMENT; LATERAL RETINACULUM; BLOOD-FLOW; OUTCOME MEASURES; ANTERIOR KNEE; PAIN SYNDROME; ADULTS; TISSUE; YOUNG; PRESSURE;
D O I
10.1186/s40634-023-00709-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose According to the homeostasis model, patellofemoral pain (PFP) results from disturbed homeostasis due to vascular insufficiency in the anterior knee. Near-Infrared Spectroscopy (NIRS) measures relative changes in concentrations (in mu mol/cm(2)) of (de-)oxygenated hemoglobine (HHb and O(2)Hb). The aims were to: 1) investigate the characteristics of the NIRS signal derived from the patella during experiments affecting hemodynamics in healthy controls, and 2) determine the test-retest reliability of NIRS in positions clinically relevant for PFP patients.Methods Two experiments were conducted on 10 healthy controls and analysed using Student's t-test. Reliability (ICC2,1) was evaluated for two activities ('Prolonged Sitting' and 'Stair Descent') in five PFP patients and 15 healthy controls, performed twice within five days.Results The NIRS signal (HHb and O(2)Hb) showed a statistically significant increase (p < .001 - .002) on all optodes (30, 35, 40 mm) during 'Venous Occlusion' (M = 1.0 - 2.0), while it showed no statistically significant change (p = .075 - .61) during 'Skin Compression' (M = -0.9 - 0.9) on the 30 and 35 mm optode. Reliability of NIRS (HHb and O(2)Hb) ranged from moderate to almost perfect (ICC2,1 = .47 - .95) on the 30 mm optode for 'Prolonged Sitting', and from moderate to substantial (ICC2,1 = .50 - .68) on the 35 mm optode for 'Stair Descent'.Conclusions Patella NIRS measurements are affected by venous occlusion, but not by skin compression, and are sufficiently reliable as research application to compare real-time patellar bone hemodynamics. These insights may assist to improve effectiveness of evidence-based treatment strategies for PFP.
引用
收藏
页数:14
相关论文
共 31 条
  • [1] Near-Infrared Spectroscopy measurements are reliable for studying patellar bone hemodynamics and affected by venous occlusion, but not by skin compression
    Martin J. Ophey
    Anne Westerweel
    Maxime van Oort
    Robert van den Berg
    Gino M. M. J. Kerkhoffs
    Igor J. R. Tak
    Journal of Experimental Orthopaedics, 10
  • [2] The Case for Measuring Long Bone Hemodynamics With Near-Infrared Spectroscopy
    Zhang, Chuan
    McCully, Kevin K.
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [3] Event-related functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?
    Plichta, M. M.
    Herrmann, M. J.
    Baehne, C. G.
    Ehlis, A. -C.
    Richter, M. M.
    Pauli, P.
    Fallgatter, A. J.
    NEUROIMAGE, 2006, 31 (01) : 116 - 124
  • [4] MEASUREMENT OF CEREBRAL VENOUS OXYHEMOGLOBIN SATURATION IN CHILDREN BY NEAR-INFRARED SPECTROSCOPY AND PARTIAL JUGULAR VENOUS OCCLUSION
    YOXALL, CW
    WEINDLING, AM
    DAWANI, NH
    PEART, I
    PEDIATRIC RESEARCH, 1995, 38 (03) : 319 - 323
  • [5] The impact of venous occlusion per se on forearm muscle blood flow: implications for the near-infrared spectroscopy venous occlusion technique
    Cross, Troy J.
    Sabapathy, Surendran
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 293 - 298
  • [6] In-vivo measurements of skin tissue by near-infrared diffuse reflectance spectroscopy
    Bittner, A
    Thomassen, S
    Heise, HM
    MIKROCHIMICA ACTA, 1997, : 429 - 432
  • [7] Mathematical model for the hemodynamic response to venous occlusion measured with near-infrared spectroscopy in the human forearm
    Van Vo, Toi
    Hammer, Peter E.
    Hoimes, Matthew L.
    Nadgir, Shalini
    Fantini, Sergio
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (04) : 573 - 584
  • [8] In vivo skin measurements with a novel probe head for simultaneous skin impedance and near-infrared spectroscopy
    Boden, Ida
    Larsson, William
    Nilsson, David
    Forssell, Erik
    Naredi, Peter
    Lindholm-Sethson, Britta
    SKIN RESEARCH AND TECHNOLOGY, 2011, 17 (04) : 494 - 504
  • [9] Near-Infrared Spectroscopy Does Not Track Forearm Blood Flow during Venous Occlusion Plethysmography
    Perlet, Michael R.
    Herren, Jeremy T.
    Traylor, Miranda K.
    Bailey, Matthew D.
    Keller, Joshua L.
    APPLIED SCIENCES-BASEL, 2024, 14 (08):
  • [10] Validation of cerebral venous oxygenation measured using near-infrared spectroscopy and partial jugular venous occlusion in the newborn lamb
    Wong, Flora Y.
    Barfield, Charles P.
    Campbell, Louisa
    Brodecky, Vojta A.
    Walker, Adrian M.