Specific absorbed fractions of electrons and photons for Digimouse voxelized phantom using GATE/GEANT4 Monte-Carlo simulation

被引:2
|
作者
Laazouzi, Khaoula [1 ]
Boukhal, Hamid [1 ]
Chakir, El Mahjoub [2 ]
Arectout, Assia [1 ]
Hadouachi, Maryam [1 ]
Belhaj, Omaima Essaad [1 ]
机构
[1] Univ Abdelmalek Essaadi, Fac Sci, Lab Radiat & Nucl Syst, Tetouan, Morocco
[2] Ibn Tofail Univ, Fac Sci, Lab Mat Phys & Subat, Kenitra, Morocco
关键词
Internal dosimetry; GATE/GEANT4; Monte Carlo; Specific absorbed fraction; Absorbed fraction; Digimouse phantom; MOUSE; DOSIMETRY; GATE; PET; CODE; CT;
D O I
10.1016/j.apradiso.2022.110637
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Knowledge of SAF at different energies is crucial for internal dosimetry. For this purpose, a set of calculated SAF values for a mouse voxelized phantom's selected organs are presented below. Values of SAF were calculated for mono-energetic photons and electrons with energy varying from 10 keV to 4 MeV using the Monte Carlo simulation via GATE/GEANT4 code (GEANT4 Application for Emission Tomography). The heart, liver, lungs, kidneys, and spleen were considered as the source organs from which the particles were released. Then, the estimated results were compared to those calculated in a previous study using EGS4 code. It is indicated that the obtained results are in good agreement with the reference values for all energies of photons and electrons, with discrepancies less than 9% and 5% for self-irradiation and cross-irradiation, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Monte Carlo calculation of photon specific absorbed fractions in digimouse voxelized phantom using InterDosi code
    El Bakkali, Jaafar
    Doudouh, Abderrahmin
    El Bardouni, Tarek
    Sahel, Omar Ait
    RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [2] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [3] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [4] Specific absorbed fractions of electrons and photons for Rad-HUMAN phantom using Monte Carlo method
    王文
    程梦云
    龙鹏程
    胡丽琴
    Chinese Physics C, 2015, (07) : 107 - 112
  • [5] Specific absorbed fractions of electrons and photons for Rad-HUMAN phantom using Monte Carlo method
    Wang Wen
    Cheng Meng-Yun
    Long Peng-Cheng
    Hu Li-Qin
    CHINESE PHYSICS C, 2015, 39 (07)
  • [6] Specific absorbed fractions of electrons and photons for Rad-HUMAN phantom using Monte Carlo method
    王文
    程梦云
    龙鹏程
    胡丽琴
    Chinese Physics C, 2015, 39 (07) : 107 - 112
  • [7] Monte Carlo simulation of the lateral spread for proton beams in voxelized water phantom using GEANT4 platform
    Kaanouch, Othmane
    Krim, Mustapha
    Ghazi, Ismail
    Saidi, Kamal
    Essaidi, El Mehdi
    Tantaoui, Meriem
    Saad, El Madani
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (01)
  • [8] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [9] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [10] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Adil Bardane
    Jaouad Tajmouaati
    Abdelmajid Maghnouj
    Moscow University Physics Bulletin, 2020, 75 : 58 - 62