Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors

被引:0
|
作者
Jin, Zhicheng [1 ,4 ]
Huang, Rongrong [2 ]
Christensen, Paul [1 ,3 ]
Bertholf, Roger L. [1 ,3 ]
Yi, Xin [1 ,3 ]
机构
[1] Houston Methodist Hosp, Dept Pathol & Genom Med, Houston, TX 77030 USA
[2] Baylor Coll Med, Harris Hlth Syst Ben Taub Hosp, Dept Pathol & Immunol, Houston, TX 77030 USA
[3] Weill Cornell Med Coll, Dept Pathol & Lab Med, New York, NY 10065 USA
[4] Univ Wisconsin, Dept Pathol & Lab Med, Madison, WI 53792 USA
关键词
glomerular filtration rate; plasma iohexol clearance; LC-MS/MS; CLINICAL-PRACTICE; GFR; SINGLE; IOTHALAMATE; CR-51-EDTA; MULTIPLE;
D O I
10.3390/jcm12186054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a "near-ideal" exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors. Methods: A workflow was established in the institution's infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed. Results: The LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor's direct media interface. Conclusions: We developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Assessment of the glomerular filtration rate (GFR) in kidney transplant recipients using Bayesian estimation of the iohexol clearance
    Riff, Camille
    Besombes, Joevin
    Gatault, Philippe
    Barbet, Christelle
    Buchler, Matthias
    Blasco, Helene
    Halimi, Jean-Michel
    Barin-Le Guellec, Chantal
    Benz-de Bretagne, Isabelle
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (04) : 577 - 587
  • [2] ACCURATE ASSESSMENT OF THE GLOMERULAR FILTRATION RATE (GFR) IN KIDNEY TRANSPLANT RECIPIENTS USING BAYESIAN ESTIMATION OF THE IOHEXOL CLEARANCE
    Besombes, J.
    Riff, C.
    Benz-De Bretagne, I.
    Gatault, P.
    Barbet, C.
    Buchler, M.
    Halimi, J. M.
    Barin-Le Guellec, C.
    [J]. TRANSPLANT INTERNATIONAL, 2020, 33 : 6 - 6
  • [3] Iohexol clearance for assessment of glomerular filtration rate in diabetic pregnancy
    Olofsson, P
    Krutzen, E
    NilssonEhle, P
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1996, 64 (01): : 63 - 67
  • [4] Use of plasma clearance of iohexol for estimating glomerular filtration rate in cats
    Miyamoto, K
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (04) : 572 - 575
  • [5] Iohexol plasma clearance in determining glomerular filtration rate in diabetic patients
    Pucci, L
    Bandinelli, S
    Penno, G
    Nannipieri, M
    Rizzo, L
    Navalesi, R
    [J]. RENAL FAILURE, 1998, 20 (02) : 277 - 284
  • [6] PLASMA IOHEXOL CLEARANCE AS A SURROGATE OF GLOMERULAR FILTRATION RATE IN CRITICALLY ILL PATIENTS WITH UNSTABLE KIDNEY FUNCTION
    Salmon-Gandonniere, C.
    Benz-de-Bretagne, I.
    Mercier, E.
    Lhommet, C.
    Joret, A.
    Halimi, J. -M
    Le Guellec, C.
    Ehrmann, S.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 : S222 - S222
  • [8] DETERMINATION OF GLOMERULAR-FILTRATION RATE BY IOHEXOL CLEARANCE
    NILSSONEHLE, P
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 1993, 51 (3-5) : 322 - 322
  • [9] PLASMA-CLEARANCE OF NONRADIOACTIVE IOHEXOL AS A MEASURE OF GLOMERULAR-FILTRATION RATE
    GASPARI, F
    PERICO, N
    RUGGENENTI, P
    MOSCONI, L
    AMUCHASTEGUI, CS
    GUERINI, E
    DAINA, E
    REMUZZI, G
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (02): : 257 - 263
  • [10] A Bayesian approach to assess glomerular filtration rate (GFR) using plasma iohexol clearance in renal transplant recipients
    Benz-De Bretagne, I.
    Blasco, H.
    Gatault, P.
    Barbet, C.
    Buechler, M.
    Andres, C. R.
    Halimi, J. M.
    Le Guellec, C.
    [J]. FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2014, 28 : 20 - 20