Efficacy of texture and color enhancement imaging for short-type single-balloon enteroscopy-assisted biliary cannulation in patients with Roux-en-Y gastrectomy: Multicenter study (with video)

被引:2
|
作者
Tanisaka, Yuki [1 ,3 ]
Takenaka, Mamoru [2 ]
Mizuide, Masafumi [1 ]
Fujita, Akashi [1 ]
Jinushi, Ryuhei [1 ]
Shin, Takahiro [1 ]
Sugimoto, Kei [1 ]
Kamata, Ken [2 ]
Minaga, Kosuke [2 ]
Omoto, Shunsuke [2 ]
Yamazaki, Tomohiro [2 ]
Ryozawa, Shomei [1 ]
机构
[1] Saitama Med Univ Int Med Ctr, Dept Gastroenterol, Saitama, Japan
[2] Kindai Univ, Fac Med, Dept Gastroenterol & Hepatol, Osaka, Japan
[3] Saitama Med Univ Int Med Ctr, Dept Gastroenterol, 1397-1 Yamane, Hidaka, Saitama 3501298, Japan
关键词
cannulation; gastrectomy; image enhancement; single-balloon enteroscopy; BILE-DUCT CANNULATION; ALTERED ANATOMY; ERCP; PAPILLA;
D O I
10.1111/den.14769
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
ObjectivesTexture and color enhancement imaging (TXI) reportedly improves the identification of the papilla of Vater for selective biliary cannulation compared with white light imaging (WLI). This multicenter study evaluated the efficacy of short-type single-balloon enteroscopy (SBE)-assisted biliary cannulation using a new-generation image-enhanced endoscopy processing system equipped with TXI in patients who underwent Roux-en-Y gastrectomy.MethodsPatients with Roux-en-Y gastrectomy with a native papilla, and underwent short SBE-assisted biliary cannulation during endoscopic retrograde cholangiopancreatography-related procedures between January 2019 and April 2023 were retrospectively reviewed. Outcomes of biliary cannulation using TXI and WLI were compared. The primary outcome was time to successful biliary cannulation.ResultsThirty-three patients underwent biliary cannulation with TXI and 98 underwent WLI. The biliary cannulation success rates and median time to successful biliary cannulation with TXI and WLI were 93.9% (95% confidence interval [CI] 79.8-99.3%) and 83.7% (95% CI 74.8-90.4%), respectively (P = 0.14), and 10 min (interquartile range [IQR] 2.5-23.5) and 18 min (IQR 9.75-24), respectively (P = 0.04). Biliary cannulation with TXI required a shorter cannulation time than that required with WLI. Adverse event rates with TXI and WLI did not differ significantly (P = 0.58). Multivariate linear regression analysis showed that the use of TXI and short length of oral protrusion were associated with a shorter successful biliary cannulation time.ConclusionShort SBE-assisted biliary cannulation was effective and safe on TXI in patients who underwent Roux-en-Y gastrectomy, and achieved shorter successful biliary cannulation time.
引用
收藏
页码:1030 / 1040
页数:11
相关论文
共 38 条
  • [1] USEFULNESS OF TEXTURE AND COLOR ENHANCEMENT IMAGING FOR SHORT-TYPE SINGLE-BALLOON ENTEROSCOPY-ASSISTED BILIARY CANNULATION IN PATIENTS WITH ROUX-EN-Y GASTRECTOMY: A MULTICENTER STUDY
    Tanisaka, Yuki
    Takenaka, Mamoru
    Mizuide, Masafumi
    Fujita, Akashi
    Shin, Takahiro
    Sugimoto, Kei
    Jinushi, Ryuhei
    Ryozawa, Shomei
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB701 - AB701
  • [2] 'Short' single-balloon enteroscopy-assisted ERCP in patients with Roux-en-Y anastomosis
    Iwano, Hirotoshi
    Ryozawa, Shomei
    Ogata, Noriyuki
    Hayashi, Seiko
    Taba, Kumiko
    Ohtsuka, Kazuo
    Miyachi, Hideyuki
    Yamamura, Fuyuhiko
    Inoue, Haruhiro
    Kudo, Shinei
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 84 - 84
  • [3] Mechanistic loop resolution strategy for short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y reconstruction after gastrectomy (with video)
    Min Jae Yang
    Jin Hong Kim
    Jae Chul Hwang
    Byung Moo Yoo
    Se Woo Park
    Chang-Il Kwon
    Seok Jeong
    Surgical Endoscopy, 2022, 36 : 8690 - 8696
  • [4] Mechanistic loop resolution strategy for short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y reconstruction after gastrectomy (with video)
    Yang, Min Jae
    Kim, Jin Hong
    Hwang, Jae Chul
    Yoo, Byung Moo
    Park, Se Woo
    Kwon, Chang-Il
    Jeong, Seok
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (11): : 8690 - 8696
  • [5] Single-Balloon Enteroscopy-Assisted ERCP in Patients With Billroth II Gastrectomy or Roux-en-Y Anastomosis
    Itoi, Takao
    Ishii, Kentaro
    Sofuni, Atsushi
    Itokawa, Fumihide
    Tsuchiya, Takayoshi
    Kurihara, Toshio
    Tsuji, Shujiro
    Ikeuchi, Nobuhito
    Umeda, Junko
    Moriyasu, Fuminori
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (01): : 93 - 99
  • [6] Correction: Mechanistic loop resolution strategy for short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y reconstruction after gastrectomy (with video)
    Min Jae Yang
    Jin Hong Kim
    Jae Chul Hwang
    Byung Moo Yoo
    Se Woo Park
    Chang-Il Kwon
    Seok Jeong
    Surgical Endoscopy, 2023, 37 (11) : 8931 - 8931
  • [7] The Usefulness of the Alpha-Retroflex Position in Biliary Cannulation on Single-Balloon Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Patients with Roux-en-Y Gastrectomy: A Retrospective Study
    Imazu, Hiroo
    Osawa, Rota
    Yamada, Koji
    Takahashi, Toshimi
    Kawamura, Muneo
    Nomura, Shuzo
    Hamana, Suguru
    Kuniyoshi, Noriyuki
    Fujisawa, Mariko
    Saito, Kei
    Kogure, Hirofumi
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [8] Mechanistic loop resolution strategy for short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y reconstruction after gastrectomy (with video) (vol 36, pg 8690, 2022)
    Yang, Min Jae
    Kim, Jin Hong
    Hwang, Jae Chul
    Yoo, Byung Moo
    Park, Se Woo
    Kwon, Chang-Il
    Jeong, Seok
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (11): : 8931 - 8931
  • [9] SHORT-TYPE SINGLE-BALLOON ENTEROSCOPY-ASSISTED ERCP FOR PATIENTS WITH SURGICALLY ALTERED ANATOMY
    Tanisaka, Yuki
    Mizuide, Masafumi
    Fujita, Akashi
    Shiomi, Rie
    Shin, Takahiro
    Sugimoto, Kei
    Ryozawa, Shomei
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB587 - AB588
  • [10] Usefulness of the "newly designed" short-type single-balloon enteroscope for ERCP in patients with Roux-en-Y gastrectomy: a pilot study
    Tanisaka, Yuki
    Ryozawa, Shomei
    Mizuide, Masafumi
    Kobayashi, Masanori
    Fujita, Akashi
    Minami, Kazuhiro
    Kobatake, Tsutomu
    Omiya, Kumiko
    Iwano, Hirotoshi
    Araki, Ryuichiro
    ENDOSCOPY INTERNATIONAL OPEN, 2018, 6 (12) : E1417 - E1422