Optimal placement of resistive superconducting fault current limiter by considering short-circuit current and transient stability of power system

被引:0
|
作者
Hafidz, Isa [1 ,2 ]
Mahendra, Rafin Aqsa Izza [1 ]
Pujiantara, Margo [1 ]
Priyadi, Ardyono [1 ]
Purnomo, Mauridhi Hery [1 ,3 ]
机构
[1] Inst Teknol Sepuluh Nopember, Dept Elect Engn, Surabaya 60111, East Java, Indonesia
[2] Inst Teknol Telkom Surabaya, Dept Elect Engn, Surabaya, Indonesia
[3] Inst Teknol Sepuluh Nopember, Dept Comp Engn, Surabaya, Indonesia
关键词
power system transient stability; short-circuit currents; superconducting fault current limiter; time-domain analysis;
D O I
10.1049/gtd2.12956
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High level of fault currents has become one of the most challenging issues, along with increased electrical energy consumption and power grid expansion. However, some of the previous work was limited to installing limiters on designs and installing them on small plans. Here, the optimal placement of a resistive-type superconducting fault current limiter (RSFCL) to achieve good power system transient stability is proposed. The proposed method has several advantages. First, procedure fault analysis is applied to consider the magnitude of the short-circuit currents and the line located close to the generator for the placement of the device. Compared with other methods, it can directly find the exact line to be installed RSFCL. Second, the stability assessment is validated using the time domain simulation by installing limiters with varying capacities in any location. Third, parameters were analysed to evaluate the proposed method's effectiveness, including angular speed, rotor angular velocity, and generator rotor angle in a multi-machine system. The result reveals that the placement of the limiter on the line with the most significant short-circuits value on the line closest to the generator increases the power system stability more than the placement in other locations. The optimal placement of a resistive-type superconducting fault current limiter (RSFCL) to achieve good power system transient stability is proposed. Procedure fault analysis is applied to consider the magnitude of the short-circuit currents and the line located close to the generator for the placement of the device. Parameters were analysed to evaluate the proposed method's effectiveness, including angular speed, rotor angular velocity and generator rotor angle in a multi-machine system.image
引用
收藏
页码:4304 / 4315
页数:12
相关论文
共 50 条
  • [1] Short circuit current level reduction in power system by optimal placement of fault current limiter
    Pham Tuan Ngoc
    Singh, Jai Govind
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2017, 27 (12):
  • [2] Influences of Resistor-Type Superconducting Fault Current Limiter on Power System Transient Stability with Asymmetrical Short-Circuit Faults
    Xue-Ping Gu and Zhi-Long Yang Department of Electric Power Engineering
    [J]. Journal of Electronic Science and Technology, 2008, (02) : 101 - 107
  • [3] Improvement of power system transient stability by superconducting fault current limiter
    Yagami, M
    Shibata, S
    Murata, T
    Tamura, J
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 359 - 364
  • [4] Enhancing transient stability of power systems using a resistive superconducting fault current limiter
    Alashqar, Mohamed
    Yang, Conghuan
    Xue, Ying
    Liu, Zhaoxi
    Zheng, Weiye
    Zhang, Xiao-Ping
    [J]. FRONTIERS IN ENERGY RESEARCH, 2023, 10
  • [5] Short-circuit fault current-limiting characteristics of a resistive-type superconducting fault current limiter in DC grids
    Xiang, Bin
    Gao, Lei
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2020, 33 (02):
  • [6] Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System
    Kim, Jin-Seok
    Lim, Sung-Hun
    Kim, Jae-Chul
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (06) : 1789 - 1794
  • [7] Designing and Current Limiting Characteristics of Magneto-biased Superconducting Fault Current Limiter Considering DC Component of Short-circuit Current
    Li C.
    Wu Q.
    Li B.
    Zhu J.
    Chen P.
    Wei D.
    Xin Y.
    [J]. Dianwang Jishu/Power System Technology, 2023, 47 (12): : 4887 - 4896
  • [8] Power system stability improvement with superconducting fault current limiter
    Didier, Gaetan
    Bonnard, Charles Henri
    Douine, Bruno
    Leveque, Jean
    [J]. 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2014,
  • [9] Parameter Design of Fault Current Limiter for High Voltage AC System Considering Transient Component of Short Circuit Current
    Liu, Jiawei
    Yuan, Jiaxin
    Zhou, Hang
    Li, Xüzhe
    Mo, Zuoquan
    [J]. Gaodianya Jishu/High Voltage Engineering, 2024, 50 (08): : 3769 - 3782
  • [10] Application of a combined superconducting fault current limiter and STATCOM to enhancement of power system transient stability
    Mahdad, Belkacem
    Srairi, K.
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2013, 495 : 160 - 168