Characterizing the rheology of lamellar gel networks with optical coherence tomography velocimetry

被引:2
|
作者
Moore, Owen Watts [1 ,2 ]
Waigh, Thomas Andrew [1 ,2 ]
Mendoza, Cesar [3 ]
Kowalski, Adam [3 ]
机构
[1] Univ Manchester, Sch Phys & Astron, Biol Phys, Oxford Rd, Manchester M13 9PL, England
[2] Univ Manchester, Photon Sci Inst, Oxford Rd, Manchester M13 9PL, England
[3] Port Sunlight Lab, Unilever Res & Dev, Quarry Rd East, Bebington CH63 3JW, England
关键词
Optical coherence tomography; Optical techniques; Velocimetry; Interferometry; Multilamellar vesicles; Onions; Lamellar gel network; Wall slip; Shear banding; Thixotropy; Yield Stress; SHEAR-INDUCED TRANSITIONS; FLUID-FLOW VELOCITY; YIELD-STRESS; PHASE; THIXOTROPY; BEHAVIOR; MODEL; SLIP;
D O I
10.1122/8.0000599
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Lamellar gel networks based on mixtures of cetostearyl alcohol and a cationic surfactant, cetyl-trimethylammonium chloride, were studied using a combination of rheometry and optical coherence tomography (OCT) velocimetry. Experiments were conducted in a stress-controlled rheometer with a parallel plate geometry. Each formulation was found to exhibit a yield stress and thixotropy. The shear start-up behavior in response to a constant stress was directly observed using OCT velocimetry. Close to the yield stress, the velocity had a power law behavior with time after an initial period of transience. At larger stresses, the velocity undergoes two successive increases in power law scaling with time. When sheared at low, constant, shear rates 1-5 s(-1), the fluids exhibit plug flow with strong wall slip at both rheometer plates. At rates of 10-150 s(-1), the fluids separate into a distinctive three shear band morphology while the wall slip reduces. These rheological properties can be explained by a multilamellar vesicle to planar lamellae transition.
引用
收藏
页码:589 / 600
页数:12
相关论文
共 50 条
  • [1] Characterizing the rheology, slip, and velocity profiles of lamellar gel networks
    Datta, Anukta
    Tanmay, Velidanda S.
    Tan, Grace X.
    Reynolds, Geoffrey W.
    Jamadagni, Sumanth N.
    Larson, Ronald G.
    JOURNAL OF RHEOLOGY, 2020, 64 (04) : 851 - 862
  • [2] Optical coherence tomography velocimetry of colloidal suspensions
    Malm, A. V.
    Harrison, A. W.
    Waigh, T. A.
    SOFT MATTER, 2014, 10 (41) : 8210 - 8215
  • [3] Optical Coherence Tomography Velocimetry with Complex Fluids
    Malm, A.
    Waigh, T. A.
    Jaradat, S.
    Tomlin, R.
    1ST INTERNATIONAL CONFERENCE ON RHEOLOGY AND MODELING OF MATERIALS (IC-RMM1), 2015, 602
  • [4] Optical coherence tomography velocimetry in controlled shear flow
    Harvey, M.
    Waigh, T. A.
    PHYSICAL REVIEW E, 2011, 83 (03):
  • [5] Characterizing arterial plaque with optical coherence tomography
    Brezinski, M
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (06) : 648 - 655
  • [6] Optical coherence tomography angiography-based capillary velocimetry
    Wang, Ruikang K.
    Zhang, Qinqin
    Li, Yuandong
    Song, Shaozhen
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (06)
  • [7] Improved velocimetry in optical coherence tomography using Bayesian analysis
    Zhou, Kevin C.
    Huang, Brendan K.
    Tagare, Hemant
    Choma, Michael A.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12): : 4796 - 4811
  • [8] The Vitreous in Uveitis: Characterizing the Invisible with Optical Coherence Tomography
    Pichi, Francesco
    Carreno, Ester
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2022, 30 (03) : 690 - 696
  • [9] Optical coherence tomography of developing lamellar macular hole.
    Otani, T
    Takahashi, H
    Kishi, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S342 - S342
  • [10] Evolution of lamellar macular hole studied by optical coherence tomography
    P. G. Theodossiadis
    V. G. Grigoropoulos
    I. Emfietzoglou
    P. Nikolaidis
    I. Vergados
    M. Apostolopoulos
    G. P. Theodossiadis
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 13 - 20