Comparative Analysis of Tolerance to Experimentally Induced Astigmatism with Three Types of Multifocal Intraocular Lenses

被引:2
|
作者
Chang, John So Min [1 ]
Liu, Sylvia Chui Ting [1 ]
Ma, Nadine Tsz Ching [1 ]
Ng, Jack Chun Man [2 ]
机构
[1] Hong Kong Sanat & Hosp, Dept Ophthalmol, Hong Kong, Peoples R China
[2] Grantham Hosp, Dept Ophthalmol, Hong Kong, Peoples R China
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
residual astigmatism; bifocal; extended depth-of-focus; trifocal; THE-RULE ASTIGMATISM; VISUAL-ACUITY; CORNEAL ASTIGMATISM; CATARACT-SURGERY; PSEUDOPHAKIC EYES; EXTENDED RANGE; DISTANCE; VISION; AXIS; PERFORMANCE;
D O I
10.2147/OPTH.S429630
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The effect of residual astigmatism and its axis on distance and near visual acuities (VAs) with multifocal intraocular lenses (IOLs) has not been studied extensively. This study compared the tolerance to experimentally induced residual astigmatism among bifocal, trifocal, and extended depth-of-focus (EDOF) IOLs. Patients and Methods: This retrospective, comparative study included 70 eyes of 70 patients implanted with bifocal, trifocal, or EDOF IOLs. Distance and near VAs were assessed with experimentally induced astigmatism by placing positive cylindrical lenses in increments of 0.50 diopters to 2.00 diopters at 90 degrees and 180 degrees axes over the best distance correction. Results: Both distance and near VAs worsened with increasing magnitudes of experimentally induced astigmatism except in the EDOF group, in which the near VA remained within a clinically acceptable limit, ie, within one line from the best corrected VA under all ranges of experimentally induced astigmatism. Furthermore, the EDOF group showed the highest astigmatic threshold for losing VA lines following experimental astigmatic induction at both distance and near. The distance VA was generally better at with-the-rule (WTR) than against-the-rule (ATR) astigmatism for all three IOL groups. On the other hand, the near VA was generally better at WTR than ATR astigmatism in the bifocal group, comparable between WTR and ATR astigmatism in the trifocal group, and generally better at ATR than WTR astigmatism in the EDOF group. Conclusion: The EDOF IOL demonstrated the highest tolerance to experimentally induced astigmatism at both distance and near. VA was generally less affected by WTR astigmatism than ATR astigmatism, especially at distance. We proposed the residual astigmatism thresholds for clinically acceptable VA reduction in all three IOL groups.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 50 条
  • [1] Effect of astigmatism on multifocal intraocular lenses
    Ravalico, G
    Parentin, F
    Baccara, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06): : 804 - 807
  • [3] Influence of astigmatism on multifocal and monofocal intraocular lenses
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 477 - 482
  • [4] Comparative effects of various types of toric intraocular lenses on astigmatism correction
    Jayoon Moon
    Chang Ho Yoon
    Mee Kum Kim
    BMC Ophthalmology, 20
  • [5] Comparative effects of various types of toric intraocular lenses on astigmatism correction
    Moon, Jayoon
    Yoon, Chang Ho
    Kim, Mee Kum
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [6] Comparative numerical analysis of astigmatism tolerance in bifocal, extended depth-of-focus, and trifocal intraocular lenses
    You, Jongin
    Jang, Mooseok
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 628 - 642
  • [7] Multifocal toric intraocular lenses versus multifocal intraocular lenses combined with peripheral corneal relaxing incisions to correct moderate astigmatism
    Gangwani, Vinod
    Hirnschall, Nino
    Findl, Oliver
    Maurino, Vincenzo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1625 - 1632
  • [8] Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses
    Hayashi, K
    Hayashi, H
    Oshika, T
    Hayashi, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (10): : 1510 - 1516
  • [9] Wavefront analysis and modulation transfer function of three multifocal intraocular lenses
    Santhiago, Marcony R.
    Netto, Marcelo V.
    Barreto, Jackson, Jr.
    Gomes, Beatriz A. F.
    Schaefer, Arthur
    Kara-Junior, Newton
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (02) : 109 - 113
  • [10] A comparative clinical study of the visual results between three types of multifocal lenses
    Gierek-Ciaciura, Stanislawa
    Cwalina, Lukasz
    Bednarski, Lukasz
    Mrukwa-Kominek, Ewa
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (01) : 133 - 140