Artificial intelligence-augmented electrocardiography for left ventricular systolic dysfunction in patients undergoing high-sensitivity cardiac troponin T

被引:3
|
作者
De Michieli, Laura [1 ,2 ]
Knott, Jonathan D. [3 ]
Attia, Zachi, I [1 ]
Ola, Olatunde [4 ,5 ]
Mehta, Ramila A. [6 ]
Akula, Ashok [4 ,5 ]
Hodge, David O. [7 ]
Gulati, Rajiv [1 ]
Friedman, Paul A. [1 ]
Jaffe, Allan S. [1 ,8 ]
Sandoval, Yader [1 ,9 ,10 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55902 USA
[2] Univ Padua, Dept Cardiac Thorac & Vasc Sci & Publ Hlth, Padua, Italy
[3] Mayo Clin, Dept Internal Med, Rochester, MN USA
[4] Mayo Clin, Dept Hosp Internal Med, Hlth Syst, La Crosse, WI USA
[5] Mayo Clin, Ctr Clin & Translat Sci, Grad Sch Biomed Sci, Rochester, MN USA
[6] Mayo Coll Med, Dept Quantitat Hlth Sci, Rochester, MN USA
[7] Mayo Coll Med, Dept Quantitat Hlth Sci, Jacksonville, FL USA
[8] Mayo Clin, Dept Lab Med & Pathol, Rochester, MN USA
[9] Abbott NW Hosp, Intervent Sect, Minneapolis Heart Inst, 920 E 28th St Suite 300, Minneapolis, MN 55407 USA
[10] Minneapolis Heart Inst Fdn, 920 E 28th St Suite 300, Minneapolis, MN 55407 USA
基金
美国国家卫生研究院;
关键词
High-sensitivity-cardiac troponin; Myocardial infarction; Myocardial injury; Artificial intelligence; Electrocardiogram; TYPE-2; MYOCARDIAL-INFARCTION; EJECTION FRACTION; IDENTIFICATION; ASSOCIATION; DIAGNOSIS; IMPACT;
D O I
10.1093/ehjacc/zuac156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Our goal was to evaluate a previously validated artificial intelligence-augmented electrocardiography (AI-ECG) screening tool for left ventricular systolic dysfunction (LVSD) in patients undergoing high-sensitivity-cardiac troponin T (hs-cTnT). Methods and results Retrospective application of AI-ECG for LVSD in emergency department (ED) patients undergoing hs-cTnT. AI-ECG scores (0-1) for probability of LVSD (left ventricular ejection fraction <= 35%) were obtained. An AI-ECG score >= 0.256 indicates a positive screen. The primary endpoint was a composite of post-discharge major adverse cardiovascular events (MACEs) at two years follow-up. Among 1977 patients, 248 (13%) had a positive AI-ECG. When compared with patients with a negative AI-ECG, those with a positive AI-ECG had a higher risk for MACE [48 vs. 21%, P < 0.0001, adjusted hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.11-1.75]. This was largely because of a higher rate of deaths (32 vs. 14%, P < 0.0001; adjusted HR 1.26, 95% 0.95-1.66) and heart failure hospitalizations (26 vs. 6.1%, P < 0.001; adjusted HR 1.75, 95% CI 1.25-2.45). Together, hs-cTnT and AI-ECG resulted in the following MACE rates and adjusted HRs: hs-cTnT < 99th percentile and negative AI-ECG: 116/1176 (11%; reference), hs-cTnT < 99th percentile and positive AI-ECG: 28/107 (26%; adjusted HR 1.54, 95% CI 1.01-2.36), hs-cTnT > 99th percentile and negative AI-ECG: 233/553 (42%; adjusted HR 2.12, 95% CI 1.66, 2.70), and hs-cTnT > 99th percentile and positive AI-ECG: 91/141 (65%; adjusted HR 2.83, 95% CI 2.06, 3.87). Conclusion Among ED patients evaluated with hs-cTnT, a positive AI-ECG for LVSD identifies patients at high risk for MACE. The conjoint use of hs-cTnT and AI-ECG facilitates risk stratification.
引用
收藏
页码:106 / 114
页数:9
相关论文
共 50 条
  • [1] Artificial Intelligence-Augmented Electrocardiogram Detection of Left Ventricular Systolic Dysfunction in the General
    Kashou, Anthony H.
    Medina-Inojosa, Jose R.
    Noseworthy, Peter A.
    Rodeheffer, Richard J.
    Lopez-Jimenez, Francisco
    Attia, Itzhak Zachi
    Kapa, Suraj
    Scott, Christopher G.
    Lee, Alexander T.
    Friedman, Paul A.
    McKie, Paul M.
    MAYO CLINIC PROCEEDINGS, 2021, 96 (10) : 2576 - 2586
  • [2] Left ventricular systolic dysfunction identification using artificial intelligence-augmented electrocardiogram in cardiac intensive care unit patients
    Jentzer, Jacob C.
    Kashou, Anthony H.
    Attia, Zachi I.
    Lopez-Jimenez, Francisco
    Kapa, Suraj
    Friedman, Paul A.
    Noseworthy, Peter A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 326 : 114 - 123
  • [3] Diagnostic Value of High-Sensitivity Troponin T for Subclinical Left Ventricular Systolic Dysfunction in Patients with Sepsis
    Hai, Pham Dang
    Binh, Nguyen Thanh
    Tot, Nguyen Hong
    Hung, Ha Manh
    Hoa, Le Thi Viet
    Hien, Nguyen Viet Quang
    Son, Pham Nguyen
    CARDIOLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [4] Artificial intelligence-enabled electrocardiographic algorithm for the detection of left ventricular dysfunction in emergency department patients undergoing high -sensitivity cardiac troponin T
    De Michieli, L.
    Knott, J.
    Attia, Z.
    Ola, O.
    Akula, A.
    Mehta, R.
    Dworak, M.
    Lobo, R.
    Hodge, D.
    Tak, T.
    Cagin, C.
    Friedman, R.
    Gulati, R.
    Jatfe, A.
    Sandoval, Y.
    EUROPEAN HEART JOURNAL, 2022, 43 : 1330 - 1330
  • [5] Association of high-sensitivity troponin T with left ventricular dysfunction in prediabetes
    Tanriverdi, Okan
    Askin, Lutfu
    ACTA CARDIOLOGICA, 2024, 79 (06) : 699 - 704
  • [6] Association of High-Sensitivity Troponin T With Left Ventricular Dysfunction in Ankylosing Spondylitis
    Turkmen, Serdar
    Askin, Lutfu
    Uzel, Kader Eliz
    Nacar, Huseyin
    Kavalci, Veysi
    Akturk, Erdal
    Selcuk, Mustafa Yavuz
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2020, 26 (03) : 87 - 93
  • [7] High-Sensitivity Cardiac Troponin T Reflects Left Ventricular Function of Non-ACS Patients
    Otsuka, Hiroaki
    Okabe, Kouta
    Yamada, Keiji
    Fujiwara, Takashi
    Miki, Takashi
    Fujita, Shinpei
    Kawamoto, Kenji
    Yamamoto, Kazuhiko
    Katayama, Yusuke
    Sakuragi, Satoru
    JOURNAL OF CARDIAC FAILURE, 2012, 18 (10) : S168 - S168
  • [8] Elevation of high-sensitivity cardiac troponin T and left ventricular remodelling in hypertrophic cardiomyopathy
    Kubo, Toru
    Ochi, Yuri
    Baba, Yuichi
    Sugiura, Kenta
    Takahashi, Asa
    Hirota, Takayoshi
    Yamanaka, Shigeo
    Yamasaki, Naohito
    Doi, Yoshinori L.
    Kitaoka, Hiroaki
    ESC HEART FAILURE, 2020, 7 (06): : 3593 - 3600
  • [9] High-Sensitivity Cardiac Troponin T in Stable Patients Undergoing Pharmacological Stress Testing
    Wongpraparut, Nattawut
    Piyophirapong, Sudarat
    Maneesai, Adisak
    Sribhen, Kosit
    Krittayaphong, Rungroj
    Pongakasira, Rungtiwa
    White, Harvey D.
    CLINICAL CARDIOLOGY, 2015, 38 (05) : 293 - 299
  • [10] Utility of high-sensitivity cardiac troponin T in patients undergoing elective coronary angiography
    Hochholzer, W.
    Valina, C. M.
    Stratz, C.
    Schlittenhardt, D.
    Trenk, D.
    Neumann, F. J.
    EUROPEAN HEART JOURNAL, 2012, 33 : 776 - 776