Estimating Local Diagnostic Reference Levels for Mammography in Dubai

被引:1
|
作者
Noor, Kaltham Abdulwahid [1 ,2 ]
Norsuddin, Norhashimah Mohd [2 ]
Karim, Muhammad Khalis Abdul [3 ]
Isa, Iza Nurzawani Che [2 ]
Alshamsi, Wadha [4 ]
机构
[1] Rashid Hosp, Radiol Dept, Dubai Hlth Acad Corp, Dubai, U Arab Emirates
[2] Univ Kebangsaan Malaysia, Fac Hlth Sci, Ctr Diagnost Therapeut & Invest Studies CODTIS, Kuala Lumpur 56000, Malaysia
[3] Univ Putra Malaysia, Fac Sci, Dept Phys, Serdang 43400, Malaysia
[4] Al Ain Hosp, Med Phys Dept, SEHA, Abu Dhabi, U Arab Emirates
关键词
diagnostic reference level; mean glandular dose; organ dose; mammography; REFERENCE LEVELS DRLS; DIGITAL MAMMOGRAPHY; SCREENING MAMMOGRAPHY; DOSE SURVEY; ESTABLISHMENT; OPTIMIZATION; RADIOGRAPHY;
D O I
10.3390/diagnostics14010008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
As the total volume of mammograms in Dubai is increasing consistently, it is crucial to focus on the process of dose optimization by determining dose reference levels for such sensitive radiographic examinations as mammography. This work aimed to determine local diagnostic reference levels (DRLs) for mammography procedures in Dubai at different ranges of breast thickness. A total of 2599 anonymized mammograms were randomly retrieved from a central dose survey database. Mammographic cases for screening women aged from 40 to 69 years were included, while cases of breast implants and breast thickness outside the range of 20-100 mm were excluded. Mean, median, and 75 percentiles were obtained for the mean glandular dose (MGD) distribution of each mammography projection for all compressed breast thickness (CBT) ranges. The local DRLs for mammography in Dubai were found to be between 0.80 mGy and 0.82 mGy for the craniocaudal (CC) projection and between 0.89 mGy and 0.971.8 mGy for the mediolateral oblique (MLO) projection. Local DRLs were proposed according to different breast thicknesses, starting from 20 to 100 mm. All groups of CBT showed a slight difference in MGD values, with higher values in MLO views rather than CC views. The local DRLs in this study were lower than some other Middle Eastern countries and lower than the standard reference levels reported by the International Atomic Energy Agency (IAEA) at 3 mGy/view.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Mammography diagnostic reference levels in Western Australia
    Storm, Cameron
    Harvey, Alicia
    Djukelic, Mario
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 1125 - 1129
  • [2] Diagnostic reference levels for mammography in BreastScreen Queensland
    David L. Thiele
    Mike Irvine
    David Want
    Michael Bernardo
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 415 - 418
  • [3] Mammography diagnostic reference levels in Western Australia
    Cameron Storm
    Alicia Harvey
    Mario Djukelic
    [J]. Physical and Engineering Sciences in Medicine, 2020, 43 : 1125 - 1129
  • [4] Diagnostic reference levels for mammography in BreastScreen Queensland
    Thiele, David L.
    Irvine, Mike
    Want, David
    Bernardo, Michael
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) : 415 - 418
  • [5] Mammography Diagnostic Reference Levels (DRLs) in Ghana
    Dzidzornu, E.
    Angmorterh, S. K.
    Ofori-Manteaw, B. B.
    Aboagye, S.
    Dzefi-Tettey, K.
    Ofori, E. K.
    [J]. RADIOGRAPHY, 2021, 27 (02) : 611 - 616
  • [6] Diagnostic Reference Levels in Mammography in the Asian Context
    Rajamuni, Chamudi Ishara
    Weerakoon, Bimali Sanjeevani
    [J]. SUDAN JOURNAL OF MEDICAL SCIENCES, 2022, 17 (03): : 402 - 416
  • [7] Local diagnostic reference levels for digital mammography: Two hospitals study in northwest, Nigeria
    Garba, I
    Bashir, H. S.
    Bello, F.
    Nuhu, K. S.
    Mohammed, S.
    Mansur, Y.
    Lawal, Y.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 435 - 442
  • [8] Diagnostic reference levels in digital mammography: a systematic review
    Suleiman, Moayyad E.
    Brennan, Patrick C.
    McEntee, Mark F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 608 - 619
  • [9] TOWARDS NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR MAMMOGRAPHY IN SERBIA
    Rafajlovic, S.
    Ciraj-Bjelac, O.
    Bozovic, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 477 - 486
  • [10] Diagnostic reference levels in digital mammography: a systematic review
    Liu, Qiumei
    Suleiman, Moayyad E.
    McEntee, Mark F.
    Soh, BaoLin P.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (01)