Experimental Study on Dust Removal Performance of Electrostatic Water Film Cyclone Dust Collector

被引:1
|
作者
Zhang, Di [1 ,2 ]
Chen, Zuyun [1 ,2 ]
Zhong, Fangquan [3 ]
Zhou, Ziyi [1 ,2 ]
机构
[1] Jiangxi Univ Sci & Technol, Sch Emergency Management & Safety Engn, Ganzhou, Peoples R China
[2] Ganzhou Key Lab Ind Safety & Emergency Technol, Ganzhou, Peoples R China
[3] Jiangxi Yaosheng Tungsten Co Ltd, Ganzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
PRECIPITATOR;
D O I
10.1155/2023/9959052
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Due to their limitations, conventional electric and water film dust removal methods struggle to handle fine dust. This study presented information on and examined the electrostatic water film cyclone dust collector (EWFCDC). By using the variable control approach, the impacts of inlet flow speed, water film flow rate, and corona pole form on dust removal performance were investigated. At EWFCDC, an orthogonal test was carried out to improve the test design and operating parameters based on the single-factor experiment. The pressure loss in the cyclone cylinder, when there is no water film and no corona pole, is a quadratic function of the inlet flow speed, and it is 2418.10 Pa at a 21.25 m/s inlet flow speed. The effectiveness of dust removal may be increased by increasing the water film flow rate. The effectiveness of dust removal is greatly influenced by the type of corona pole used, and cage needling thread is the optimal type. The electrostatic water film cyclone's multimechanism coupling significantly increases the effectiveness of dust removal.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Experimental investigations on the performance of the electrostatic cyclone dust collector
    Wang, J
    Du, H
    Xu, KY
    [J]. ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1758 - 1762
  • [2] The Model for the Separation Efficiency of the Electrostatic Cyclone Dust Collector
    Luo, Jiajun
    Zhang, Hao
    Yang, Dong
    Zhang, Jiguang
    Tang, Huajun
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 695 - 703
  • [3] A study on flow performance of axial inlet cyclone for dust collector
    Kim, I. K.
    Kim, J. S.
    [J]. Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 1321 - 1324
  • [4] A revised equilibrium-path model for the electrostatic cyclone dust collector
    Wang, J
    Du, H
    Xu, KY
    [J]. ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1751 - 1757
  • [5] The Experimental Study of Performance Ejecting Dust Collector in Mine
    Li, Haizhan
    Wang, Zhuliang
    Wang, Hongyu
    [J]. PROCEEDINGS OF THE 2015 ASIA-PACIFIC ENERGY EQUIPMENT ENGINEERING RESEARCH CONFERENCE (AP3ER 2015), 2015, 9 : 19 - 22
  • [6] An experimental study on the characterization of electric charge in electrostatic dust removal
    Sayyah, Arash
    Crowell, David R.
    Raychowdhury, Atri
    Horenstein, Mark N.
    Mazumder, Malay K.
    [J]. JOURNAL OF ELECTROSTATICS, 2017, 87 : 173 - 179
  • [7] HOW TO CHOOSE A CYCLONE DUST COLLECTOR
    DOERSCHLAG, C
    MICZEK, G
    [J]. CHEMICAL ENGINEERING, 1977, 84 (04) : 64 - 72
  • [8] A Study on the Design of Dust Collector Chamber to Improve the Performance of Electric Dust Collector
    Bang, Il Ho
    Kim, Hak Min
    Yeom, Jeong Kuk
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2022, 46 (08) : 399 - 408
  • [9] Experimental study and efficiency optimization on water film dust removal of wet chord grid
    Wang, Haiqiao
    Wu, Zhirong
    Chen, Shiqiang
    Wang, Pengfei
    Huang, Minhua
    [J]. Meitan Xuebao/Journal of the China Coal Society, 2023, 48 (01): : 279 - 289
  • [10] Study on dust removal mechanism of wet cyclone scrubber
    Hu, Fei
    Hu, Shengyong
    Gao, Yang
    Wang, Hetang
    Feng, Guorui
    Liu, Changhe
    Li, Jihua
    [J]. Meitan Kexue Jishu/Coal Science and Technology (Peking), 2022, 50 (08): : 118 - 124