Experimental and numerical simulation research on heat transfer performance of coaxial casing heat exchanger in 3500m-deep geothermal well in Weihe Basin

被引:13
|
作者
Du, Dingshan [1 ,2 ]
Li, Yongqiang [2 ]
Wang, Kaipeng [2 ]
Zhao, Yongzhe [2 ]
Hu, Zhenyang [2 ]
Zhang, Weidong [2 ]
Wang, Qilong [2 ]
机构
[1] China Coal Res Inst, Beijing 100013, Peoples R China
[2] China Coal Technol & Engn Grp Corp, Xian Res Inst Grp Co Ltd, Xian 710077, Peoples R China
关键词
Deep coaxial borehole heat exchanger; Field test; Thermal insulation performance of inner tube; Numerical simulation; Sensitivity analysis; EXTRACTION PERFORMANCE; SUSTAINABILITY;
D O I
10.1016/j.geothermics.2023.102658
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The deep coaxial borehole heat exchanger (DCBHE), as an important part of the deep-seated ground heat exchanger system, undertakes the important task of heat exchange with the underground geotechnical body to provide heating for the building. In this paper, through field test, numerical simulation and sensitivity analysis, the influence of thermal insulation performance of inner tube, heat preservation method of inner tube and diameter ratio of inner tube to outer tube on heat extraction capacity of deep coaxial borehole heat exchanger is studied. Field tests in intermittent operation mode (9.5 h operation and 14.5 h shutdown) show that the short-term single-well heat extraction capacity of the deep coaxial borehole heat exchanger using the vacuum gel steel tube with a thermal conductivity of 0.002 W/(m center dot K) as the inner tube is 574.96 W/m. The simulation results show that the diameter ratio of the inner and outer tubes has little effect on the heat extraction capacity, and the diameter ratio of the inner and outer tubes of 0.65 has the smallest resistance loss along the way. For heat exchanger with depth of 3500 m, the location of severe thermal interference between the inner and outer tubes is mainly located in the upper part of the heat exchanger near the surface, especially in the 1400 m to 2100 m section. The research results can provide a reference for the optimization design of medium-deep coaxial heat exchange buried pipe system and the promotion of medium-deep geothermal energy utilization.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Study on the heat transfer performance of coaxial casing heat exchanger for medium and deep geothermal energy in cold regions
    Li, Mingqi
    Shi, Yan
    Chen, Hongxu
    Liu, Chengcheng
    Li, Hongchao
    [J]. Renewable Energy, 2024, 237
  • [2] Numerical Investigation of the Coaxial Geothermal Heat Exchanger Performance
    Benyoub, M.
    Aour, B.
    Oudrane, A.
    Sadek, K.
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2024, 69 : 71 - 90
  • [3] Numerical analysis of heat extraction performance of a deep coaxial borehole heat exchanger geothermal system
    Song, Xianzhi
    Wang, Gaosheng
    Shi, Yu
    Li, Ruixia
    Xu, Zhengming
    Zheng, Rui
    Wang, Yu
    Li, Jiacheng
    [J]. ENERGY, 2018, 164 : 1298 - 1310
  • [4] Field Test and Numerical Simulation on Heat Transfer Performance of Coaxial Borehole Heat Exchanger
    Li, Peng
    Guan, Peng
    Zheng, Jun
    Dou, Bin
    Tian, Hong
    Duan, Xinsheng
    Liu, Hejuan
    [J]. ENERGIES, 2020, 13 (20)
  • [5] Numerical study on the effects of design parameters on the heat transfer performance of coaxial deep borehole heat exchanger
    Liu, Jun
    Wang, Fenghao
    Cai, Wanlong
    Wang, Zhihua
    Wei, Qingpeng
    Deng, Jiewen
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (12) : 6337 - 6352
  • [6] Numerical investigation on heat transfer performance of the segmented cementing coaxial heat exchanger
    Zheng, Jianqiao
    Zhang, Yanjun
    Huang, Yibin
    Liu, Qiangbin
    Cheng, Yuxiang
    Guo, Jixiang
    [J]. RENEWABLE ENERGY, 2024, 220
  • [7] Numerical study on the heat transfer performance of coaxial shallow borehole heat exchanger
    Li G.
    Yang J.
    Zhu X.
    Shen Z.
    [J]. Energy and Built Environment, 2021, 2 (04): : 445 - 455
  • [8] Numerical simulation of a novel spiral type ground heat exchanger for enhancing heat transfer performance of geothermal heat pump
    Saeidi, Reza
    Noorollahi, Younes
    Esfahanian, Vahid
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 168 : 296 - 307
  • [9] Simulation Research of the Impact on the Heat Transfer Capability of Structural Changes in Casing Heat Exchanger
    Liao, Baisheng
    [J]. ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1378 - 1382
  • [10] Study of Heat Transfer Characteristics and Economic Analysis of a Closed Deep Coaxial Geothermal Heat Exchanger Retrofitted from an Abandoned Oil Well
    Liu, Rui-Jia
    Jia, Lin-Rui
    Zhang, Wen-Shuo
    Yu, Ming-Zhi
    Zhao, Xu-Dong
    Cui, Ping
    [J]. SUSTAINABILITY, 2024, 16 (04)