Determination of trace elements in mineral water by MIP OES using the Marin-5 nebulization system

被引:0
|
作者
Martins, Alexsandro S. [1 ,2 ]
Dantas Filho, Heronides Adonias [2 ]
Dantas, Kelly Fernandes G. [2 ]
机构
[1] Secretary State & Educ, BR-66820000 Belem, PA, Brazil
[2] Fed Univ Para, Inst Exact & Nat Sci, Fac Chem, Grp Appl Analyt Spectrometry, BR-66075110 Belem, PA, Brazil
关键词
Number:; -; Acronym:; CAPES; Sponsor: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior;
D O I
10.1039/d3ja00068k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, three analytical procedures for the determination of inorganic constituents in mineral water were performed. To increase sensitivity, the Marin-5 nebulization system was coupled to ICP OES and MIP OES for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb determination in mineral water and, thus, meet the requirements of Brazilian legislation. The accuracy of MIP OES and ICP OES measurements was evaluated using the certified water reference material (NIST 1643e). Recovery rates obtained ranged from 83% to 117%. The use of the Marin-5 nebulization system provided an increase in sensitivity, leading to limits of detection that were up to 6 times lower for ICP OES and 3 times lower for MIP OES. In addition, it made it possible for both techniques to meet the maximum limits allowed by Brazilian legislation for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb in mineral water. Most water samples had concentrations within limits established by Brazilian legislation for mineral water, except for Al and Pb, which in four samples exceeded the maximum allowed limits.
引用
收藏
页码:1007 / 1015
页数:9
相关论文
共 50 条
  • [1] A COMPARISON OF ETV AND LA FOR THE DETERMINATION OF TRACE ELEMENTS IN SOLID SAMPLES BY MIP OES
    Matusiewicz, Henryk
    Slachcinski, Mariusz
    ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S, 2019, 26 (03): : 429 - 441
  • [2] Determination of Trace Elements in Meat and Fish Samples by MIP OES Using Solid-Phase Extraction
    de Sa, Ivero Pita
    Higuera, Julymar Marcano
    Costa, Vinicius Camara
    Costa, Jose Arnaldo Santana
    da Silva, Caio Marcio Paranhos
    Nogueira, Ana Rita Araujo
    FOOD ANALYTICAL METHODS, 2020, 13 (01) : 238 - 248
  • [3] Determination of Trace Elements in Meat and Fish Samples by MIP OES Using Solid-Phase Extraction
    Ivero Pita de Sá
    Julymar Marcano Higuera
    Vinicius Câmara Costa
    José Arnaldo Santana Costa
    Caio Marcio Paranhos da Silva
    Ana Rita Araujo Nogueira
    Food Analytical Methods, 2020, 13 : 238 - 248
  • [4] ICP-OES determination of trace elements in salinated water samples
    Mitko, K
    Bebek, M
    ATOMIC SPECTROSCOPY, 1999, 20 (06) : 217 - 223
  • [6] Comparison of ICP-MS and ICP-OES in the Determination of Trace Elements in Water
    Cidu, R.
    Atomic Spectroscopy, 17 (04):
  • [7] Study on the direct determination of trace elements in the city tap water by ICP-OES
    Wei, Y. S.
    Zheng, M. Y.
    Geng, W.
    Gu, Y. Z.
    WATER RESOURCES AND ENVIRONMENT, 2016, : 343 - 346
  • [9] Straightforward determination of U, Th, and Hf at trace levels using ultrasonic nebulization and axial view ICP OES
    Martins, C. A.
    Scheffler, G. L.
    Pozebon, D.
    ANALYTICAL METHODS, 2016, 8 (03) : 504 - 509
  • [10] Determination of Trace Elements Content in Mineral Water and its Processed Mineral Water by ICP-MS
    Rui, Yukui
    Zhang, Yanbei
    Li, Shengliang
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (09) : 5103 - 5104