Comparison of Point-of-Care and Laboratory Glycated Hemoglobin A1c and Its Relationship to Time-in-Range and Glucose Variability: A Real-World Study

被引:0
|
作者
Al Hayek, Ayman [1 ]
Alzahrani, Wael M. [1 ]
Sobki, Samia H. [2 ]
Al-Saeed, Abdulghani H. [1 ]
Al Dawish, Mohamed [1 ]
机构
[1] Prince Sultan Mil Med City, Dept Endocrinol & Diabet, Riyadh, Saudi Arabia
[2] Saudi Soc Clin Chem, Dept Clin Chem, Riyadh, Saudi Arabia
关键词
glucose variability; time-in-range; saudi arabia; laboratory hba1c; poct hba1c; diabetes mellitus; GLYCEMIC VARIABILITY; DIABETES-MELLITUS; COMPLICATIONS; MANAGEMENT;
D O I
10.7759/cureus.33416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The main objective of the current study was to perform a comparison of point-of-care testing for hemoglobin A1c (POCT-HbA1c) versus the standard laboratory method (Lab HbA1c) and their relationship to time-in-range (TIR) and glucose variability (GV) among patients with diabetes mellitus (DM) presented to the outpatient diabetes clinics. Methods This single-center cross-sectional study was carried out on diabetic patients (aged >= 14 years of both genders) who undergo routine follow-up at our institution and whose physicians ordered HbA1c analysis for routine care. The included patients were those using the intermittently scanned continuous glucose monitoring (isCGM) Abbott's FreeStyle Libre system for at least three months and regular CGM users with at least 70% use. Results We included 97 diabetic patients (41 female and 56 male), with a median age of 25 years ( Interquartile range= 18) and a mean DM duration of 10.33 +/- 5.48 years. The mean values of Lab-HbA1c and POCT HbA1c were 8.82%+/- 0.85% and 8.53%+/- 0.89%, respectively. The TIR, time below range, and time above range were 33.47 +/- 14.38 minutes (47.78%+/- 14.32%), 5.44 +/- 2.58 minutes (8.41%+/- 4.42%), and 28.8 +/- 8.27 minutes (43.81%+/- 13.22%), respectively. According to the Bland-Altman plot analysis, the POCT-HbA1c values are consistent with the standard Lab-HbA1c values (SD of bias= 0.55, and 95% CI= -0.78 to 1.4). The univariate linear regression analysis showed a statistically significant relationship between laboratory HbA1c and POCT HbA1c (R2= 0.637, p <0.001), TIR (R2= 0.406, p <0.001), and GV (R2= 0.048, p= 0.032). After adjusting for age, gender, disease duration, diabetes type, and percentage of sensor data in a multivariable linear regression model, the linear associations remained significant (all p < 0.05). Conclusion The current findings show that TIR and GV can be used as endpoints and valuable parameters for the therapy of DM.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] COMPARISON OF POINT-OF-CARE AND LABORATORY GLYCATED HEMOGLOBIN A1C AND ITS RELATIONSHIP TO TIME-IN-RANGE AND GLUCOSE VARIABILITY: A REAL-WORLD STUDY
    Al Hayek, A.
    Al Dawish, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A233 - A233
  • [2] The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes
    Vigersky, Robert A.
    McMahon, Chantal
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (02) : 81 - 85
  • [3] Translating glycated hemoglobin A1c into time spent in glucose target range: A multicenter study
    Petersson, Jonathan
    Akesson, Karin
    Sundberg, Frida
    Sarnblad, Stefan
    PEDIATRIC DIABETES, 2019, 20 (03) : 339 - 344
  • [4] THE RELATIONSHIP OF HEMOGLOBIN A1C TO CGM-DERIVED TIME-IN-RANGE IN PATIENTS WITH DIABETES
    Vigersky, R.
    McMahon, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A119 - A120
  • [5] Time in range-A1c hemoglobin relationship in continuous glucose monitoring of type 1 diabetes: a real-world study
    Valenzano, Marina
    Bertolotti, Ivan Cibrario
    Valenzano, Adriano
    Grassi, Giorgio
    BMJ OPEN DIABETES RESEARCH & CARE, 2021, 9 (01)
  • [6] Discordant Point-of-Care and Laboratory Hemoglobin A1c Concentrations in Ambulatory Settings
    Korpi-Steiner, Nichole
    Cotten, Steven W.
    Little, Randie R.
    Kirk, Deepa
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2024, 10 (02): : 519 - 522
  • [7] Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer
    Wiwanitkit, V.
    ARCHIVES OF HELLENIC MEDICINE, 2010, 27 (06): : 953 - 955
  • [8] RELATIONSHIP BETWEEN HEMOGLOBIN A1C, TIME-IN-RANGE AND GLYCEMIC VARIABILITY IN TYPE 1 DIABETES PATIENTS UNDER INTERMITTENTLY SCANNED CONTINUOUS GLUCOSE MONITORING.
    Diaz Soto, G.
    Gomez Hoyos, E.
    Jimenez, R.
    Nieto De La Marca, M. D. L. O.
    Vidueira, A. M.
    De Luis, D.
    Bahillo Curieses, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A124 - A124
  • [9] Performance evaluation of the glycated hemoglobin A1c analyzer for point-of-care testing compared with laboratory-based devices: a multicenter validation study
    Zhou, Yiwen
    Yang, Fan
    Zhou, Mi
    Pan, Baishen
    Wang, Beili
    Guo, Wei
    Shao, Wenqi
    Zhu, Jing
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2024, 84 (05): : 356 - 361
  • [10] Retrospective Accuracy Study of Point-of-Care Hemoglobin A1c in Field Conditions
    Manthei, David M.
    Wesener, Nicholas
    Twarkowski, Denise
    Giacherio, Donald A.
    Schroeder, Lee F.
    CLINICAL CHEMISTRY, 2017, 63 (03) : 780 - 781