Multidisciplinary cooperative mode led by infusion nurse specialists used to ensure the nursing quality of peripherally inserted central catheters in China: A 5-year retrospective study

被引:5
|
作者
Cao Jie [1 ]
Peng Chunxue [1 ]
Xu Jiawei [1 ]
Li Hongmei [2 ]
Qian Huohong [3 ,4 ]
机构
[1] Naval Med Univ, Changhai Hosp, Dept Urol, Shanghai, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Infus Therapy Clin, Shanghai, Peoples R China
[3] Naval Med Univ, Changhai Hosp, Infus Therapy Board, Shanghai, Peoples R China
[4] Shanghai Nurses Assoc, Infus Therapy Comm, Shanghai, Peoples R China
来源
JOURNAL OF VASCULAR ACCESS | 2023年 / 24卷 / 03期
关键词
Multidisciplinary cooperative mode; infusion nurse specialists; nursing quality; peripherally inserted central catheters; PICC; EXPERIENCE; REMOVAL;
D O I
10.1177/11297298211033507
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To analyze the effect of multidisciplinary cooperation mode (MCM) led by infusion nurse specialists (INSs) on peripherally inserted central catheters (PICC) catheterization and indwelling nursing quality. Methods: Participants' demographic information, catheter types, catheterization approaches, puncture site, tip position, professional title of nurses, success rate of catheterization, consultation rate, detection rate of complications and outcome improvement rate of 6576 outpatients and hospitalized patients with PICC were analyzed retrospectively by a software named "questionnaire stars," in a large tertiary general hospital in Shanghai, from January 2015 to December 2019. SPSS 26.0 for Windows was used for data collection and description, Chi-square test were used for statistical analysis of enumeration data, and p < 0.05 was statistically significant. Results: According to the catheter types' data, the use rate of three-way valve catheters decreased from 79.9% to 14.5%, while the use rate of three-way valve solo catheters increased from 12.7% to 51.6%, and the use rate of power injectable and open-ended catheters increased from 7.4% to 33.9%. According to the data of PICC catheterization method, conventional technology decreased significantly from 16.8% to 1.1%, modified Seldinger technique (MST) increased gradually from 26.1% to 51.3%, while ultrasound guided modified Seldinger technique (US and MST) decreased slightly from 57.2% to 47.6%. 7.5% catheter tip ends were malpositioned while nine indwelled PICCs were traced to have tip end malposition. The consultation rate was significantly higher than that before applying MCM led by INSs (x(2) = 151.713, p < 0.05). After applying MCM led by INSs, the detection rate of complications was significantly higher than before (x(2) = 5.499, p < 0.05), the rate of successful insertion at one time was significantly higher than before (x(2) = 187.589, p < 0.05). Conclusion: After the application of INSs-led MCM, progresses have been achieved. The nursing quality of patients' PICC was significantly improved than before.
引用
收藏
页码:370 / 378
页数:9
相关论文
共 4 条
  • [1] Role of Peripherally Inserted Central Catheters in Home Parenteral Nutrition: A 5-Year Prospective Study
    Botella-Carretero, Jose I.
    Carrero, Carmen
    Guerra, Eva
    Valbuena, Beatriz
    Arrieta, Francisco
    Calanas, Alfonso
    Zamarron, Isabel
    Balsa, Jose A.
    Vazquez, Clotilde
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2013, 37 (04) : 544 - 549
  • [2] Peripherally inserted central catheters in non-hospitalized cancer patients: 5-year results of a prospective study
    Paolo Cotogni
    Cristina Barbero
    Cristina Garrino
    Claudia Degiorgis
    Baudolino Mussa
    Antonella De Francesco
    Mauro Pittiruti
    Supportive Care in Cancer, 2015, 23 : 403 - 409
  • [3] Peripherally inserted central catheters in non-hospitalized cancer patients: 5-year results of a prospective study
    Cotogni, Paolo
    Barbero, Cristina
    Garrino, Cristina
    Degiorgis, Claudia
    Mussa, Baudolino
    De Francesco, Antonella
    Pittiruti, Mauro
    SUPPORTIVE CARE IN CANCER, 2015, 23 (02) : 403 - 409
  • [4] A six-year study of complications related to peripherally inserted central catheters: A multi-center retrospective cohort study in China
    Wan, Rong
    Gu, Lilei
    Yin, Bi
    Cai, Shengwei
    Zhou, Rengui
    Yang, Weilin
    PERFUSION-UK, 2023, 38 (04): : 689 - 697