Appraisal of masonry infill walls dynamic characteristics: An analytical study

被引:3
|
作者
Mohamed, Hossameldeen [1 ]
Furtado, Andre [2 ]
Rodrigues, Hugo [3 ]
机构
[1] Aswan Univ, Fac Engn, Mailbox 81542, Aswan, Egypt
[2] Univ Lisbon, Dept Civil Engn, Inst Super Tecn, CERIS Civil Engn Res & Innovat Sustainabil, Lisbon, Portugal
[3] Univ Aveiro, Dept Civil Engn, RISCO, Aveiro, Portugal
关键词
Masonry infill walls; Out-of-plane behaviour; Modal identification; Detailed numerical modelling; Boundary conditions; Wall geometry; Openings; OF-PLANE BEHAVIOR; SEISMIC RESPONSE; 2011; LORCA; RC FRAMES; PERFORMANCE; BUILDINGS; IDENTIFICATION;
D O I
10.1016/j.engstruct.2023.116995
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the infill masonry high vulnerability observed in recent earthquakes, the knowledge concerning the infills' out-of-plane seismic behaviour has been the focus of several research works in the last years. The inplane/out-of-plane interaction, boundary conditions, openings, slenderness, and aspect ratio have been reported as the main parameters that affect the out-of-plane infill wall capacity. However, the study of the impact of those parameters on the wall modal properties still needs further investigation. This research aims to perform a numerical study where a detailed numerical strategy is assumed to simulate the infilled reinforced concrete frames. The numerical model is calibrated using results from modal identification tests (wall with and without openings). A parametric study is carried out to assess the effect of wall geometry, slenderness, openings ratio, openings position and boundary conditions on the walls' out-of-plane frequencies. Eventually, analytical formulations were proposed to quantify the dynamic characteristics of the infill wall based on their geometric and mechanical characteristics.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Modal identification of infill masonry walls with different characteristics
    Furtado, Andre
    Rodrigues, Hugo
    Arede, Antonio
    Varum, Humberto
    ENGINEERING STRUCTURES, 2017, 145 : 118 - 134
  • [2] Appraisal of masonry infill walls effect in the seismic response of RC framed buildings: A case study
    Uva, G.
    Porco, F.
    Fiore, A.
    ENGINEERING STRUCTURES, 2012, 34 : 514 - 526
  • [3] Recent Results on Masonry Infill Walls
    Willam, K. J.
    Citto, C.
    Shing, P. B.
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 27 - +
  • [4] IDENTIFICATION OF INFILL MASONRY WALLS STIFFENING CONTRIBUTION ON THE DYNAMIC BEHAVIOUR OF STEEL FRAMES
    Nicoletti, Vanni
    Regni, Marco
    Speranza, Elisa
    Arezzo, Davide
    Carbonari, Sandro
    Gara, Fabrizio
    8TH IOMAC INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE, 2019, : 315 - 320
  • [5] Impact of seismic rehabilitation and presence of unreinforced masonry (URM) infill walls on the dynamic characteristics of a hospital building in Montreal
    Asgarian, Amin
    McClure, Ghyslaine
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2014, 41 (08) : 748 - 760
  • [6] Redundancy in Steel Frames with Masonry Infill Walls
    Ghaffarzadeh, Hosein
    Ghalghachi, Robab Naseri
    World Academy of Science, Engineering and Technology, 2009, 58 : 923 - 929
  • [7] Importance of Masonry Infill Walls for Framed Buildings
    Constantinescu, Sorina
    2017 8TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (CIEM), 2017, : 465 - 469
  • [8] Experimental investigation of confined masonry infill walls
    Leal G, J. M.
    Perez Gavilan, J. J.
    Castorena G, J. H.
    Velazquez D, J., I
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 2319 - 2326
  • [9] Strengthening of Infill Masonry Walls with FRP Materials
    Lunn, Dillon S.
    Rizkalla, Sami H.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (02) : 206 - 214
  • [10] Strengthening masonry infill walls with reinforced plaster
    Altin, S.
    Anil, O.
    Kopraman, Y.
    Belgin, C.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2010, 163 (05) : 331 - 342