Long-term crack monitoring of prestressed concrete structures by means of distributed fiber-optic strain sensing

被引:2
|
作者
Kindler, Arne [1 ]
Schaller, Maria-Barbara [2 ]
Noether, Nils [3 ]
Breuer, Stefan [4 ]
机构
[1] Stump Franki Spezialtiefbau GmbH, Valeska Gert Str 1, D-10243 Berlin, Germany
[2] Gesell Geomech & Baumesstech mbH, Leipziger Str 14, D-04571 Rotha, Germany
[3] FibrisTerre Syst GmbH, Torellstr 7, D-10243 Berlin, Germany
[4] Solifos AG, Sussbachareal 1, CH-5210 Windisch, Switzerland
关键词
fiber-optic monitoring; optical fiber; civil engineering; prestressed concrete construction; case study;
D O I
10.1002/bate.202300025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the ceiling area of a connecting subway tunnel in Munich, Germany, fiber-optic sensor cables were installed for continuous long-term crack monitoring. According to the measurement concept, continuous monitoring of the total deformations as well as several reference date measurements are planned with regard to the actual crack monitoring of the prestressed concrete construction. The aim of the measurements is the fiberoptic crack monitoring of a pre-damaged prestressed concrete structure from the 1970s, which was refurbished in the course of the fiber-optic installation. The structure is exposed to high traffic loads from road traffic as well as temperature impact. The prestressed concrete structure is a single span slab construction with straight and parabolic tendons. The original ceiling had an increased potential for damage on the underside of the slab (crack pattern) as well as severe damages associated with the existing prestressing steel structure. During the renovation of the prestressed concrete slab, shotcrete with supplementary reinforcement was applied to achieve an announcement behavior in case of tendon failure. The following paper reports on the first results of crack monitoring based on continuous fiber optic measurements along the embedded fiber-optic sensing cables. The measurements are based on the technology of distributed Brillouin sensing.
引用
收藏
页码:383 / 395
页数:13
相关论文
共 50 条
  • [1] Monitoring of long-term prestress losses in prestressed concrete structures using fiber optic sensors
    Abdel-Jaber, Hiba
    Glisic, Branko
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2019, 18 (01): : 254 - 269
  • [2] Long-term monitoring of reinforced earth structures using distributed fiber optic sensing
    Moser F.
    Lienhart W.
    Woschitz H.
    Schuller H.
    Journal of Civil Structural Health Monitoring, 2016, 6 (03) : 321 - 327
  • [3] Distributed fiber optic sensing for crack detection in concrete structures
    Fischer, Oliver
    Thoma, Sebastian
    Crepaz, Simone
    BETON- UND STAHLBETONBAU, 2019, 114 (03) : 150 - 159
  • [4] Distributed fiber optic sensing for crack detection in concrete structures
    Fischer, Oliver
    Thoma, Sebastian
    Crepaz, Simone
    Civil Engineering Design, 2019, 1 (3-4): : 97 - 105
  • [5] Analysis of Fiber-Optic Strain-Monitoring Data from a Prestressed Concrete Bridge
    Webb, G. T.
    Vardanega, P. J.
    Hoult, N. A.
    Fidler, P. R. A.
    Bennett, P. J.
    Middleton, C. R.
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (05)
  • [6] Distributed Fiber-Optic Sensing and Integrity Monitoring
    Glisic, Branko
    Inaudi, Daniele
    TRANSPORTATION RESEARCH RECORD, 2010, (2150) : 96 - 102
  • [8] Crack Monitoring on Concrete Structures using Robust Distributed Fiber Optic Sensors
    Herbers, Max
    Richter, Bertram
    Marx, Steffen
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 644 - 653
  • [9] Distributed Fiber-Optic Strain Sensing in Deep Mixed Columns
    Hov, Sølve
    Meland, Henrik
    Helvacioglu, Anil
    Thurner, Robert
    Amdal, Åse Marit Wist
    Journal of Geotechnical and Geoenvironmental Engineering, 2025, 151 (02)
  • [10] Distributed Fiber Optic Shape Sensing of Concrete Structures
    Monsberger, Christoph M.
    Lienhart, Werner
    SENSORS, 2021, 21 (18)