Determination of Venetoclax Concentration in Plasma Using High-Performance Liquid Chromatography

被引:14
|
作者
Yasu, Takeo [1 ]
Gando, Yoshito [1 ]
Nomura, Yuka [1 ]
Kosugi, Nobuharu [2 ]
Kobayashi, Masayuki [2 ]
机构
[1] Meiji Pharmaceut Univ, Pharmaceut Educ & Res Ctr, Dept Med Therapy Res, 2-522-1 Noshio, Kiyose, Tokyo 2048588, Japan
[2] Tokyo Metropolitan Bokutoh Hosp, Dept Hematol, Sumida Ku, 4-23-15 Kotobashi, Tokyo 1308575, Japan
关键词
Acute myeloid leukemia - B-Cell Lymphoma - Body surface - Chronic lymphocytic leukemias - High-performance liquid chromatography - Plasma concentration - Protein inhibitors - Surface area - Surface weight - Therapeutic drug monitoring;
D O I
10.1093/chromsci/bmac027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Venetoclax is an oral B-cell lymphoma-2 protein inhibitor. It is a key drug for the treatment of chronic lymphocytic leukemia and acute myeloid leukemia. However, venetoclax is administered at a fixed dose, irrespective of body surface area or weight. Furthermore, the plasma concentration of venetoclax varies widely between individuals and is influenced by diet. Therefore, individualized dosing using therapeutic drug monitoring (TDM) may help to optimize treatment in clinical practice. In this study, we aimed to develop a simple method to determine venetoclax concentrations in plasma. The analysis required the extraction of a 50-mu L plasma sample and precipitation of proteins using acetonitrile extraction. Venetoclax and the internal standard (12.5-mu g/mL ibrutinib) were separated by high-performance liquid chromatography (HPLC). The calibration curve was linear over the plasma venetoclax concentration range 0.25-10 mu g/mL with a coefficient of determination (r(2)) of 0.9999. The coefficients of intra-day and inter-day validation were 0.8-4.1% and 1.3-3.3%, respectively. The assay accuracy was -2.8 to 1.6%, and the recovery was >97.2%. These results demonstrate a very simple, novel and sensitive HPLC-UV-based method for determining the concentration of plasma venetoclax, and confirm its applicability to the TDM of venetoclax in a clinical setting.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [1] Simple determination of plasma ibrutinib concentration using high-performance liquid chromatography
    Yasu, Takeo
    Momo, Kenji
    Yasui, Hiroshi
    Kuroda, Seiichirou
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (03)
  • [2] Simple method for determination of terbutaline plasma concentration by high-performance liquid chromatography
    Herring, VL
    Johnson, JA
    JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 307 - 312
  • [4] Determination of plasma phenobarbital concentration by high-performance liquid chromatography in rat offspring
    Moriyama, M
    Yamashita, S
    Domoto, H
    Furuno, K
    Araki, H
    Gomita, Y
    JOURNAL OF CHROMATOGRAPHY B, 1999, 723 (1-2): : 301 - 305
  • [5] DETERMINATION OF CIMETIDINE IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KATRUKHA, SP
    DAVYDOV, SM
    SELINA, EV
    KUKES, VG
    KHIMIKO-FARMATSEVTICHESKII ZHURNAL, 1988, 22 (01): : 123 - 125
  • [6] DETERMINATION OF THIOPROLINE IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LANKELMA, J
    PENDERS, PGM
    LEYVA, A
    PINEDO, HM
    CANCER LETTERS, 1981, 12 (1-2) : 131 - 137
  • [7] Determination of Insulin in Rabbit Plasma Using High-Performance Liquid Chromatography
    Yilmaz, Bilal
    Kadioglu, Yucel
    KAFKAS UNIVERSITESI VETERINER FAKULTESI DERGISI, 2012, 18 (01) : 31 - 36
  • [8] DETERMINATION OF XYLAZINE IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ALVINERIE, M
    TOUTAIN, PL
    JOURNAL OF CHROMATOGRAPHY, 1981, 222 (02): : 308 - 310
  • [9] Determination of gabapentin in plasma by high-performance liquid chromatography
    Forrest, G
    Sills, GJ
    Leach, JP
    Brodie, MJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 681 (02): : 421 - 425
  • [10] Determination of hypericin in plasma by high-performance liquid chromatography
    Chi, JD
    Franklin, M
    JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01): : 195 - 198