Enhancing the performance of a solar air heater by employing the broken V-shaped ribs

被引:2
|
作者
Rajendran, Vijayakumar [1 ]
Vikram, Muthuraman Ponrajan [2 ]
Kim, Sung Chul [3 ]
Gullo, Paride [4 ]
Alodhayb, Abdullah [5 ]
Pandiaraj, Saravanan [6 ]
Prabakaran, Rajendran [3 ]
机构
[1] Natl Engn Coll, Dept Mech Engn, KR Nagar, Kovilpatti 628503, Tamilnadu, India
[2] SIMATS, Inst Mech Engn, Saveetha Sch Engn, Chennai 602105, India
[3] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[4] Univ Southern Denmark SDU, Dept Mech & Elect Engn, Als 2, DK-6400 Sonderborg, Denmark
[5] King Saud Univ, Coll Sci, Dept Phys & Astron, POB 2455, Riyadh 11451, Saudi Arabia
[6] King Saud Univ, Dept Basic Sci & Selfdev skills, CFY Deanship, POB 2455, Riyadh 11451, Saudi Arabia
关键词
Solar energy; Air heaters; Surface modification; Baffles; Thermal efficiency; THERMAL PERFORMANCE; THERMOHYDRAULIC PERFORMANCE; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; TRANSVERSE RIBS; CFD ANALYSIS; FLUID-FLOW;
D O I
10.1007/s11356-023-27814-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work aims to enhance the performance of a solar air heater (SAH) by introducing broken V-ribs as roughness elements on the absorber plate. The unit with a conventional flat absorber plate is referred to as the "FSAH," while the unit with a broken V-rib-shaped absorber plate is called the "VSAH." The experiment was performed for three air velocities: 25 m/s, 20 m/s, and 15 m/s and the corresponding air flow rates were 0.037 kg/s, 0.031 kg/s, and 0.023 kg/s, respectively. The results showed that the maximum temperature was experienced on the absorber plate, followed by the glass plate for both SAHs. Overall, the average absorber and glass plate temperatures of the VSAH were 0.6-1.4 degrees C and 0.4-1.9 degrees C lower than those of the FSAH. Compared to the FSAH, the experimental results showed that the VSAH experienced useful power and thermal efficiency that were 16.6-19.8% and 15.7-20.4% higher, respectively, while the top surface heat losses were found to decrease by 2.1-8.1%. Due to the disrupted air paths in the VSAH, the observed pressure drop was 113.3-133.3% higher than that of the FSAH. More impotently, the thermo-hydraulic performance factor was always higher 1 and the observed values were 1.48, 1.39, and 1.24 at the v(a) (velocity) values of 15, 20, and 25 m/s, respectively. Therefore, the proposed VSAH had an admirable thermal performance as compared to FSAH. Further, optimization through varying the roughness parameters, namely, relative blockage width (W/w), relative pitch ratio (P/e), number of baffles (n), relative blockage height (e/H), and angle of attack (beta) could helped to achieve better performance.
引用
下载
收藏
页码:77807 / 77818
页数:12
相关论文
共 50 条
  • [1] Enhancing the performance of a solar air heater by employing the broken V-shaped ribs
    Vijayakumar Rajendran
    Muthuraman Ponrajan Vikram
    Sung Chul Kim
    Paride Gullo
    Abdullah Alodhayb
    Saravanan Pandiaraj
    Rajendran Prabakaran
    Environmental Science and Pollution Research, 2023, 30 : 77807 - 77818
  • [2] Thermal performance analysis of triangular solar air heater duct having broken V-shaped ribs
    Agrawal R.K.
    Prasad R.S.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [3] Hydrothermal performance of humid air flow in a rectangular solar air heater equipped with V-shaped ribs
    Kadijani, Omid Nouri
    Moghadam, Hamid Kazemi
    Ajarostaghi, Seyed Soheil Mousavi
    Asadi, Asgar
    Pour, Mohsen Saffari
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (07) : 2276 - 2289
  • [4] Thermohydraulic performance of solar air heater with staggered multiple V-shaped ribs on the absorber plate
    Jin, Dongxu
    Zuo, Jianguo
    Quan, Shenglin
    Xu, Shiming
    Gao, Hao
    ENERGY, 2017, 127 : 68 - 77
  • [5] A detailed review on various V-shaped ribs roughened solar air heater
    Jain, Sheetal Kumar
    Das Agrawal, Ghanshyam
    Misra, Rohit
    HEAT AND MASS TRANSFER, 2019, 55 (12) : 3369 - 3412
  • [6] A detailed review on various V-shaped ribs roughened solar air heater
    Sheetal Kumar Jain
    Ghanshyam Das Agrawal
    Rohit Misra
    Heat and Mass Transfer, 2019, 55 : 3369 - 3412
  • [7] Experimental Assessment of Thermohydraulic Performance of a Rectangular Solar Air Heater Duct Using Twisted V-Shaped Staggered Ribs
    Kumar, Dheeraj
    Layek, Apurba
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (04)
  • [8] Numerical investigation of heat transfer enhancement in a solar air heater roughened by multiple V-shaped ribs
    Jin, Dongxu
    Quan, Shenglin
    Zuo, Jianguo
    Xu, Shiming
    RENEWABLE ENERGY, 2019, 134 : 78 - 88
  • [9] Numerical assessment of solar air heater performance having a broken arc and broken S-shaped ribs as roughness
    Haldia, Shivam
    Bisht, Vijay Singh
    Bhandari, Prabhakar
    Ranakoti, Lalit
    Negi, Akashdeep
    ARCHIVES OF THERMODYNAMICS, 2024, 45 (01) : 23 - 31
  • [10] Numerical investigation of fluid flow and heat characteristics of a roughened solar air heater with novel V-shaped ribs
    Allauddin, Usman
    Khan, Waqar A.
    Ali, Saim E.
    Haider, Syed M. M.
    Ahmed, Abdul S.
    Rehman, Abdur
    Verdin, Patrick G.
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2022, 46 (03) : 561 - 572