Ultrasound-guided breast biopsy using an adapted automated cone-based ultrasound scanner: a feasibility study

被引:0
|
作者
Nikolaev, Anton V. [1 ,4 ]
de Jong, Leon [1 ]
Zamecnik, Patrik [1 ]
Groenhuis, Vincent [2 ]
Siepel, Francoise J. [2 ]
Stramigioli, Stefano [2 ]
Hansen, Hendrik H. G. [1 ]
de Korte, Chris L. [1 ,3 ]
机构
[1] Radboud Univ Nijmegen, Med Ultrasound Imaging Ctr MUS, Dept Med Imaging Radiol, Med Ctr, Nijmegen, Netherlands
[2] Univ Twente, Robot & Mechatron, Enschede, Netherlands
[3] Univ Twente, TechMed Ctr, Phys Fluids Grp, Enschede, Netherlands
[4] Radboud Univ Nijmegen, Med Ultrasound Imaging Ctr MUS, Dept Med Imaging Radiol, Med Ctr, NL-6525 GA Nijmegen, Netherlands
基金
欧盟地平线“2020”;
关键词
breast biopsy; image fusion; ultrasound-guided biopsy; CORE-NEEDLE-BIOPSY; ACCURACY; DIAGNOSIS; MRI; REGISTRATION; DISPLACEMENT; CANCER; SIZE;
D O I
10.1002/mp.16323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAmong available breast biopsy techniques, ultrasound (US)-guided biopsy is preferable because it is relatively inexpensive and provides live imaging feedback. The availability of magnetic resonance imaging (MRI)-3D US image fusion would facilitate US-guided biopsy even for US occult lesions to reduce the need for expensive and time-consuming MRI-guided biopsy. In this paper, we propose a novel Automated Cone-based Breast Ultrasound Scanning and Biopsy System (ACBUS-BS) to scan and biopsy breasts of women in prone position. It is based on a previously developed system, called ACBUS, that facilitates MRI-3D US image fusion imaging of the breast employing a conical container filled with coupling medium. PurposeThe purpose of this study was to introduce the ABCUS-BS system and demonstrate its feasibility for biopsy of US occult lesions. MethodThe biopsy procedure with the ACBUS-BS comprises four steps: target localization, positioning, preparation, and biopsy. The biopsy outcome can be impacted by 5 types of errors: due to lesion segmentation, MRI-3D US registration, navigation, lesion tracking during repositioning, and US inaccuracy (due to sound speed difference between the sample and the one used for image reconstruction).For the quantification, we use a soft custom-made polyvinyl alcohol phantom (PVA) containing eight lesions (three US-occult and five US-visible lesions of 10 mm in diameter) and a commercial breast mimicking phantom with a median stiffness of 7.6 and 28 kPa, respectively. Errors of all types were quantified using the custom-made phantom. The error due to lesion tracking was also quantified with the commercial phantom.Finally, the technology was validated by biopsying the custom-made phantom and comparing the size of the biopsied material to the original lesion size. The average size of the 10-mm-sized lesions in the biopsy specimen was 7.00 +/- 0.92 mm (6.33 +/- 1.16 mm for US occult lesions, and 7.40 +/- 0.55 mm for US-visible lesions). ResultsFor the PVA phantom, the errors due to registration, navigation, lesion tracking during repositioning, and US inaccuracy were 1.33, 0.30, 2.12, and 0.55 mm. The total error was 4.01 mm. For the commercial phantom, the error due to lesion tracking was estimated at 1.10 mm, and the total error was 4.11 mm. Given these results, the system is expected to successfully biopsy lesions larger than 8.22 mm in diameter. Patient studies will have to be carried out to confirm this in vivo. ConclusionThe ACBUS-BS facilitates US-guided biopsy of lesions detected in pre-MRI and therefore might offer a low-cost alternative to MRI-guided biopsy. We demonstrated the feasibility of the approach by successfully taking biopsies of five US-visible and three US-occult lesions embedded in a soft breast-shaped phantom.
引用
收藏
页码:3475 / 3489
页数:15
相关论文
共 50 条
  • [1] Ultrasound-guided breast biopsy
    Wilson, Robin
    EJC SUPPLEMENTS, 2004, 2 (03): : 47 - 49
  • [2] Ultrasound-guided breast biopsy
    不详
    EJC SUPPLEMENTS, 2006, 4 (02): : 31 - 32
  • [3] Ultrasound-Guided Percutaneous Breast Biopsy
    Newell, Mary S.
    Mahoney, Mary C.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 17 (01) : 23 - 31
  • [4] Stereotactic and ultrasound-guided breast biopsy
    Helbich T.H.
    Matzek W.
    Fuchsjäger M.H.
    European Radiology, 2004, 14 (3) : 383 - 393
  • [5] Ultrasound-guided needle biopsy of the breast
    Staren, ED
    O'Neill, TP
    SURGERY, 1999, 126 (04) : 629 - 634
  • [6] Quantitative Evaluation of an Automated Cone-Based Breast Ultrasound Scanner for MRI-3D US Image Fusion
    Nikolaev, Anton, V
    de Jong, Leon
    Weijers, Gert
    Groenhuis, Vincent
    Mann, Ritse M.
    Siepel, Francoise J.
    Maris, Bogdan M.
    Stramigioli, Stefano
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (04) : 1229 - 1239
  • [7] Ultrasound-guided renal biopsy: experience using an automated core biopsy system
    Chan, R
    Common, AA
    Marcuzzi, D
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2000, 51 (02): : 107 - 113
  • [8] Ultrasound-guided biopsy of nonpalpable breast lesions
    Fornage, BD
    10TH INTERNATIONAL CONGRESS ON SENOLOGY - BREAST DISEASES OF THE SENOLOGIC INTERNATIONAL SOCIETY, 1998, : 43 - 48
  • [9] Ultrasound-guided needle biopsy of the breast - Discussion
    Folk, FA
    Staren
    Velanovich, V
    Dunnington, G
    SURGERY, 1999, 126 (04) : 634 - 635
  • [10] Augmenting MRI–transrectal ultrasound-guided prostate biopsy with temporal ultrasound data: a clinical feasibility study
    Farhad Imani
    Bo Zhuang
    Amir Tahmasebi
    Jin Tae Kwak
    Sheng Xu
    Harsh Agarwal
    Shyam Bharat
    Nishant Uniyal
    Ismail Baris Turkbey
    Peter Choyke
    Peter Pinto
    Bradford Wood
    Mehdi Moradi
    Parvin Mousavi
    Purang Abolmaesumi