Investigation of measurement methods for soil thermal conductivity based on optical frequency domain reflection technology

被引:2
|
作者
Cheng, Lin [1 ]
Zhang, Yuheng [1 ]
Zhang, Anan [1 ]
Sun, Yongkang [1 ]
Cao, Yang [1 ]
Xu, Zengguang [1 ]
机构
[1] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, Xian 710048, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical frequency domain reflectometry; (OFDR) technology; Thermal response; Thermal conductivity; Linear heat source model;
D O I
10.1016/j.ijthermalsci.2024.108889
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal conductivity is an important parameter reflecting the heat transfer capacity of soil. In engineering applications, the thermal conductivity of soil varies with influencing factors such as particle size, porosity, water content, saturation, and seepage velocity of soil. At present, the thermal probe method and the traditional thermal response test method are mainly used to determine the thermal conductivity of soil. However, these methods can only perform point temperature measurements and require an inversion calculation based on a particular heat transfer model to obtain the value of soil thermal conductivity. Compared with this and other temperature monitoring methods, optical frequency domain reflectometry (OFDR) offers the advantages of distributed measurement, high measurement accuracy, high spatial resolution, and fast speed. In this paper, an OFDR-based measurement of soil thermal conductivity is designed. Taking sand as an example, the influence of different influencing factors on the measured value of thermal conductivity of soil was studied through the measurement test of thermal conductivity of soil, and the results are compared with the calculation results of the theoretical model of thermal conductivity and the results measured by the thermal probe method. The test results showed that when there was no seepage in the soil, the thermal conductivity of the soil exhibited an "S"-shaped growth trend with increasing water content; when the soil had seepage, the thermal conductivity of the soil was larger than that without seepage, and the thermal conductivity showed a positive linear increase with the increase in seepage velocity; With the increase of heating power, the measurement results tend to be stable. By comparing with the results obtained by other methods, the measurement results of the thermal conductivity measurement method proposed in this study have high accuracy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Optical Measurement of Thermal Conductivity Using Fiber Aligned Frequency Domain Thermoreflectance
    Malen, Jonathan A.
    Baheti, Kanhayalal
    Tong, Tao
    Zhao, Yang
    Hudgings, Janice A.
    Majumdar, Arun
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (08):
  • [2] Nonuniform strain measurement in composite material based on optical frequency domain reflection
    Li, Huajun
    Zhang, Dongsheng
    Li, Litong
    Wu, Mengqi
    Wen, Xiaoyan
    OPTICAL ENGINEERING, 2016, 55 (06)
  • [3] Thermal conductivity measurement of hydrate based on TDTR technology
    Zhang Z.
    Yuan C.
    Fan X.
    Zhu J.
    Zhao J.
    Tang D.
    Huagong Xuebao/CIESC Journal, 2019, 70 : 54 - 61
  • [4] Research on the evolution and application of mining-induced fractures based on the optical frequency domain reflection technology
    Wang, Kun
    Meng, Xiangrui
    Cheng, Xiang
    Zhao, Guangming
    Qi, Minjie
    Caikuang yu Anquan Gongcheng Xuebao/Journal of Mining and Safety Engineering, 2024, 41 (05): : 1000 - 1010
  • [5] Optical Frequency Domain Distributed Polarization Measurement Technology and Applications (Invited)
    Yu Zhangjun
    Yang Jun
    Zou Chen
    Lin Cuofu
    Wang Yuncai
    Qin Yuwen
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (01)
  • [6] Research on the ultra-weak reflective fiber bragg grating sensing technology based on optical frequency domain reflection technology
    National Engineering Laboratory for Fiber Optic Sensing Technology, Wuhan University of Technology, Wuhan
    Hubei
    430070, China
    不详
    Hubei
    430070, China
    Guangxue Xuebao, 8
  • [7] Instantaneous frequency measurement technology based on optical sampling
    Yan, Hao
    Zhao, Guoqing
    Qin, Guodong
    Dianbo Kexue Xuebao/Chinese Journal of Radio Science, 2014, 29 (01): : 72 - 78
  • [8] METHODS OF MEASUREMENT OF THERMAL CONDUCTIVITY OF GRAPHITES
    LUTKOV, AI
    VOLGA, VI
    DYMOV, BK
    ANUFRIEV, YP
    INDUSTRIAL LABORATORY, 1970, 36 (03): : 394 - &
  • [9] High-Precision Optical Fibre Network Health Online Monitoring System Based on Incoherent Optical Frequency Domain Reflection Technology
    Yu Miao
    Ji Shunbing
    Liu Hai
    Yang Guang
    Huang Shengjun
    Liu Jun
    He Yutong
    Sun Mingyang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (04):
  • [10] Experimental study on leakage monitoring of buried water pipelines based on actively heated optical frequency domain reflection technology
    Cheng, Lin
    Zhang, Yuheng
    Wang, Zhaohan
    Sun, Yongkang
    Ma, Chunhui
    Xu, Zengguang
    Hu, Jiang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 211