A custom MR-compatible dataglove for fMRI of the human motor cortex at 7T

被引:0
|
作者
Hodono, Shota [1 ]
Jin, Jin [2 ]
Zimmermann, Jan [3 ]
Maillet, Donald [1 ]
Reutens, David [1 ]
Cloos, Martijn A. [1 ]
机构
[1] Univ Queensland, Ctr Adv Imaging, St Lucia, Qld 4072, Australia
[2] Siemens Healthcare Ply Ltd Brisbane, Brisbane, Qld, Australia
[3] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
基金
澳大利亚研究理事会;
关键词
D O I
10.1109/EMBC40787.2023.10341187
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a custom-built MR-compatible data glove to capture hand motion during concurrent fMRI experiments at 7 Tesla. Thermal and phantom tests showed our data glove can be used safely and without degradation of image quality. Subject-specific Blood Oxygen Level Dependent (BOLD) signal models, for use in fMRI analysis, were constructed based on recorded kinematic measurements. Experiments revealed the relative fMRI BOLD signal contribution of flexing, extending, and sustained isotonic extension. The ability to evaluate subject performance in real-time and create subject-specific BOLD signal models enables a wide range of experimental paradigms with improved data quality.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Effects of transcranial focused ultrasound on human primary motor cortex using 7T fMRI: a pilot study
    Leo Ai
    Priya Bansal
    Jerel K. Mueller
    Wynn Legon
    BMC Neuroscience, 19
  • [2] Effects of transcranial focused ultrasound on human primary motor cortex using 7T fMRI: a pilot study
    Ai, Leo
    Bansal, Priya
    Mueller, Jerel K.
    Legon, Wynn
    BMC NEUROSCIENCE, 2018, 19
  • [3] Mechanisms of speed encoding in the human middle temporal cortex measured by 7T fMRI
    Gaglianese, Anna
    Fracasso, Alessio
    Fernandes, Francisco G.
    Harvey, Ben
    Dumoulin, Serge O.
    Petridou, Natalia
    HUMAN BRAIN MAPPING, 2023, 44 (05) : 2050 - 2061
  • [4] High-Resolution 7T MR Imaging of the Motor Cortex in Amyotrophic Lateral Sclerosis
    Cosottini, M.
    Donatelli, G.
    Costagli, M.
    Ienco, E. Caldarazzo
    Frosini, D.
    Pesaresi, I.
    Biagi, L.
    Siciliano, G.
    Tosetti, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 455 - 461
  • [5] Safety for Human MR Scanners at 7T
    Okada, Tomohisa
    Akasaka, Thai
    Thuy, Dinh H. D.
    Isa, Tadashi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (04) : 531 - 537
  • [6] A Fineset Cortex Atlas of Human Brain Based On Boundary Mapping Technique: An 7T fMRI Study
    Han, Ziteng
    Wang, Luyao
    Yan, Tianyi
    Wu, Jinglong
    2021 2ND INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND INTELLIGENT CONTROL (ICCEIC 2021), 2021, : 29 - 34
  • [7] Balancing objects on the feet - an fMRI experiment using the MR-compatible stepper MARCOS
    Jaeger, Lukas
    Hollnagel, Christoph
    Summermatter, Severin
    Marchal-Crespo, Laura
    Michels, Lars
    Kollias, Spyros
    Riener, Robert
    2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 350 - 354
  • [8] Intracortical depth analyses of frequency-sensitive regions of human auditory cortex using 7T fMRI
    Ahveninen, Jyrki
    Chang, Wei-Tang
    Huang, Samantha
    Keil, Boris
    Kopco, Norbert
    Rossi, Stephanie
    Bonmassar, Giorgio
    Witzel, Thomas
    Polimeni, Jonathan R.
    NEUROIMAGE, 2016, 143 : 116 - 127
  • [9] A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T
    Sengupta, Shubharthi
    Roebroeck, Alard
    Kemper, Valentin G.
    Poser, Benedikt A.
    Zimmermann, Jan
    Goebel, Rainer
    Adriany, Gregor
    PLOS ONE, 2016, 11 (12):
  • [10] Cerebral blood volume sensitive layer-fMRI in the human auditory cortex at 7T: Challenges and capabilities
    Faes, Lonike K.
    De Martino, Federico
    Huber, Laurentius
    PLOS ONE, 2023, 18 (02):