Preclinical evaluation of performance, safety and usability of VAX-ID®, a novel intradermal injection device

被引:1
|
作者
Beyers, Koen C. L. [1 ,4 ]
Rbeihat, Momen N. M. [1 ]
Vasconcelos, Daniele S. [1 ]
Pasmans, Danielle [1 ]
Verwulgen, Stijn [1 ,3 ]
Vankerckhoven, Vanessa V. J. [1 ,2 ]
机构
[1] Idevax BV, Wijnegem, Belgium
[2] Univ Antwerp, Ctr Evaluat Vaccinat, Antwerp, Belgium
[3] Univ Antwerp, Fac Design Sci, Dept Prod Dev, Antwerp, Belgium
[4] Idevax BV, Bijkhoevelaan 32c, B-2110 Wijnegem, Belgium
关键词
Intradermal injection; Drug delivery; Vaccination; Performance; Usability; Device; HIGH-FREQUENCY ULTRASOUND; SKIN THICKNESS; DELIVERY; VACCINATION; ADULTS;
D O I
10.1016/j.vaccine.2023.06.028
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The recent SARS-Cov2 pandemic and mpox health emergency have led to renewed interest in intradermal vaccination due toits dose sparing potential. Indeed, intradermal vaccination is particularly of interest for use in mass vaccination campaigns, pandemic preparedness programs, and/or for vaccines that are expensive or in short supply. Moreover, the rich immune network in the skin makes it an attractive target not only for prophylactic vaccination, but also for therapeutic vaccination, like immunotherapy and (dendritic) cell-based therapies.The aim of the current paper was to provide an overview of preclinical data generated with VAX-ID & REG;, a novel intradermal drug delivery device, to allow assessing it performance, safety and usability. The device can overcome challenges seen with the Mantoux technique whereby the needle needs to be inserted under a shallow angle. Various parameters of VAX-ID & REG; were evaluated, including dead-space volume, dose accuracy, penetration depth & liquid deposit in piglets, as well as usability by healthcare professionals.The device has shown to have a low dead volume and a high dose accuracy. Importantly, the device performed successful injections at a predefined depth into the dermis with a high safety profile as confirmed by visual and histological evaluation in piglets. Moreover, the device was rated as easy to use by healthcare professionals.The combined preclinical performance and usability findings indicate that VAX-ID & REG; can provide reliable, standardized and accurate drug delivery in the dermal layer of the skin with a high ease of use. The device offers a solution for injection of various prophylactic as well as therapeutic vaccines.& COPY; 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:4609 / 4615
页数:7
相关论文
共 50 条
  • [1] Immunogenicity and safety of intradermal delivery of hepatitis B booster vaccine using the novel drug delivery device VAX-ID™
    Van Mulder, T. J. S.
    Withanage, K.
    Beyers, K. C. L.
    Vankerckhoven, V. V. J.
    Theeten, H.
    Van Damme, P.
    VACCINE, 2019, 37 (04) : 581 - 586
  • [2] Performance and usability evaluation of novel intradermal injection device ImmuciseTM and reanalysis of intradermal administration trials of influenza vaccine for the elderly
    Shimizu, Sakiko
    Tanaka, Ryo
    Itoh, Eriko
    Maekawa-Matsuura, Minami
    Iwase, Yoichiro
    VACCINE, 2022, 40 (06) : 873 - 879
  • [3] Preclinical safety evaluation of a novel helical rotational thrombectomy device
    Future, Adrian
    Houser, Stuart L.
    Wood, Todd
    Howk, Kreg A.
    Simmons, Quincey R.
    Sauro, Dennis
    Badway, Dan
    Smith, Chad
    Giugliano, Gregory R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 35B - 35B
  • [4] Preclinical development of an automated injection device for intradermal delivery of a cell-based therapy
    Giulia Leoni
    Alex Lyness
    Patrick Ginty
    Rindi Schutte
    Gopalan Pillai
    Gayatri Sharma
    Paul Kemp
    Natalie Mount
    Michaela Sharpe
    Drug Delivery and Translational Research, 2017, 7 : 695 - 708
  • [5] Preclinical development of an automated injection device for intradermal delivery of a cell-based therapy
    Leoni, Giulia
    Lyness, Alex
    Ginty, Patrick
    Schutte, Rindi
    Pillai, Gopalan
    Sharma, Gayatri
    Kemp, Paul
    Mount, Natalie
    Sharpe, Michaela
    DRUG DELIVERY AND TRANSLATIONAL RESEARCH, 2017, 7 (05) : 695 - 708
  • [6] Preclinical and clinical evaluation on the performance and safety of a novel energy-based device for body shaping: A pilot study
    Mezzana, Paolo
    Antonucci, Maria Giordana
    Fusco, Irene
    JOURNAL OF COSMETIC DERMATOLOGY, 2021, 20 (08) : 2486 - 2492
  • [7] SUMMARY OF PRECLINICAL SAFETY EVALUATION OF GADOTERIDOL INJECTION
    SOLTYS, RA
    INVESTIGATIVE RADIOLOGY, 1992, 27 : S7 - S11
  • [8] Usability, performance and safety of a new device for degenerative mitral regurgitation: in vivo chronic evaluation
    Zeitani, Jacob
    Chiariello, Giovanni Alfonso
    Shofti, Rona
    Bruno, Piergiorgio
    Massetti, Massimo
    Alfieri, Ottavio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 35 (01)
  • [9] PRECLINICAL EFFICACY AND SAFETY EVALUATION OF A BIOARTIFICIAL KIDNEY DEVICE
    Mihajlovic, Milos
    Krebber, Merle
    Westphal, Koen
    Mihaila, Silvia
    Sparidans, Rolf
    Donato, Danilo
    Gerritsen, Karin
    Storr, Markus
    Masereeuw, Rosalinde
    TISSUE ENGINEERING PART A, 2022, 28 : S175 - S175
  • [10] Performance comparison of a novel intradermal injection system with the Mantoux technique
    Tanizaki, Hideaki
    Nakashima, Chisa
    Shimizuhira, Chihiro
    Miyachi, Yoshiki
    Kabashima, Kenji
    JOURNAL OF DERMATOLOGICAL SCIENCE, 2015, 79 (03) : 310 - 313