Seismic Evaluation Approaches for Spent Fuel Pool Structures in Nuclear Power Plants

被引:3
|
作者
Hsu, Wei-Hung [1 ]
Chai, Juin-Fu [1 ]
Lin, Fan-Ru [1 ]
机构
[1] Natl Ctr Res Earthquake Engn, 200, Sec 3, Xinhai Rd, Taipei 106219, Taiwan
关键词
Spent fuel pool; FE model analysis; seismic evaluation; hydrodynamic model;
D O I
10.1142/S0219455423501882
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The United States Nuclear Regulatory Commission issued requests for licensees to re-evaluate the seismic hazards at their sites after the accident at the Fukushima Daiichi Nuclear Power Plant in Japan on March 11 in 2011 and to identify and address any site-specific vulnerabilities associated with seismic hazards. The primary guidance for performing those evaluations is provided in the Electric Power Research Institute EPRI-1025287 report, which also provides guidance for evaluating spent fuel pool (SFP) integrity. In addition, the EPRI-3002009564 report also provides evaluation approaches regarding the effects of seismic ground motions on SFPs that supplement the guidance provided in EPRI-1025287. SFP integrity has become increasingly important for active and decommissioned nuclear power plants. According to EPRI-1025287, the SFP integrity evaluation emphasizes failure modes of the SFP that could result in "rapid drain-down." The definition of "rapid drain-down" is a failure that could lead to the uncovering of irradiated fuel stored in the SFP within 72h of an earthquake. Possible failures can be classified into two categories: failures relevant to the SFP structure and failures relevant to non-structural elements. This paper aims to study the approaches of implementing seismic evaluation of an SFP structure. EPRI-3002009564 provides separate seismic evaluation approaches for plants with a ground motion response spectrum (GMRS) peak Sa = 0.8g and for plants with a GMRS peak Sa > 0.8g. Structural dynamic analysis is also a common approach for implementing seismic evaluation if a detailed finite element model is available. In this paper, a sample SFP structure was evaluated using the two approaches, structural dynamic analysis and structural analysis criteria. The results indicate that shear failure controlled the failure mode of the SFP structure for both approaches. This shows that the two approaches drew the same conclusion regarding the failure mode. Furthermore, a smaller seismic margin was obtained using the structural analysis criteria, which means this evaluative approach is more conservative.
引用
收藏
页数:31
相关论文
共 50 条
  • [1] The fluid-structure interaction seismic analysis of the BWR nuclear power plant spent fuel pool
    Shen, Yu-Yu
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (06)
  • [2] INTERIM STORAGE OF SPENT NUCLEAR FUEL IN THE UAE NUCLEAR POWER PLANTS
    Al Saadi, Sara
    Yi, Yongsun
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 4, 2014,
  • [3] STUDY ON SPENT FUEL POOL AND STORAGE OF THE ADVANCED NUCLEAR POWER PLANT
    Ling Yun
    Zhang Chao
    Li Lei
    Qian Hao
    Ge Honghui
    Xia Zufeng
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [4] Rising needs management of spent fuel at nuclear power plants
    Dyck, Peter H.
    Crijns, Martin J.
    IAEA Bulletin, 1998, 40 (01):
  • [5] DISPOSAL OF SPENT FUEL FROM GERMAN NUCLEAR POWER PLANTS
    Graf, Reinhold
    Filbert, Wolfgang
    Brammer, Klaus-Juergen
    Bollingerfehr, Wilhelm
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL REMEDIATION AND RADIOACTIVE WASTE MANAGEMENT 2009, VOL 1, 2010, : 649 - 659
  • [6] Sensitivity studies in spent fuel pool criticality safety analysis for APR-1400 nuclear power plants
    Al Awad, Abdulrahman S.
    Habashy, Abdalla
    Metwally, Walid A.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (05) : 709 - 716
  • [7] NUCLEAR SAFETY OF SPENT FUEL POOL STORAGE AT NUCLEAR POWER PLANTS WITH VVER-1000: PHYSICAL PRINCIPLES AND STRUCTURAL SOLUTIONS
    Osadchii, A. I.
    ATOMIC ENERGY, 2011, 110 (01) : 1 - 5
  • [8] Nuclear safety of spent fuel pool storage at nuclear power plants with VVER-1000: physical principles and structural solutions
    A. I. Osadchii
    Atomic Energy, 2011, 110 : 1 - 5
  • [9] Seismic isolation of pool-type tanks for the storage of nuclear spent fuel assemblies
    Park, JH
    Koh, HM
    Kim, JK
    NUCLEAR ENGINEERING AND DESIGN, 2000, 199 (1-2) : 143 - 154
  • [10] Nuclear Safety of an RBMK Spent Fuel Pool
    G. B. Davydova
    L. N. Zakharova
    A. M. Fedosov
    Atomic Energy, 2016, 119 : 221 - 228