Cool roof strategies for urban thermal resilience to extreme heatwaves in tropical cities

被引:15
|
作者
Khorat, Samiran [1 ]
Das, Debashish [2 ]
Khatun, Rupali [1 ]
Aziz, Sk Mohammad [3 ]
Anand, Prashant [4 ]
Khan, Ansar [5 ]
Santamouris, Mattheos [6 ]
Niyogi, Dev [7 ,8 ]
机构
[1] Jadavpur Univ, Sch Environm Studies, Kolkata, India
[2] Jadavpur Univ, Dept Architecture, Kolkata, India
[3] Vidyasagar Univ, Narajole Raj Coll, Dept Chem, Midnapore, India
[4] Indian Inst Technol, Departmentof Architecture & Reg Planning, Kharagpur, India
[5] Univ Calcutta, Lalbaba Coll, Dept Geog, Kolkata, India
[6] Univ New South Wales, Sch Built Environm, Sydney, Australia
[7] Univ Texas Austin, Jackson Sch Geosci, Dept Geol Sci, Austin, TX USA
[8] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX USA
关键词
Extreme urban heat events; Albedo-enhancing roofing solutions; Integrated urban climate modeling; Urban heat resilience strategies; Kolkata urban heat mitigation; HEAT-ISLAND; BOUNDARY-LAYER; CANOPY MODEL; PART I; IMPACT; CLIMATE; SIMULATION; WRF; PARAMETERIZATION; URBANIZATION;
D O I
10.1016/j.enbuild.2023.113751
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Extreme heatwaves in tropical cities represent a significant short-term weather challenge, directly impacting urban heat, exacerbating human discomfort, and increasing energy demands. To alleviate this, meteorological adjustments utilizing reflective roofing technologies, such as cool roofs, can effectively mitigate heatwaveinduced excess heat and enhance thermal comfort. This study assessed the effectiveness of cool roofs in cooling urban areas following heatwaves in Kolkata, India, using comprehensive city-scale simulations. The study presumed that the existing roofing materials, with a reflectivity of 0.15 and emissivity of 0.85, indicated the unmitigated condition. These materials were replaced with third-generation cool roof materials featuring a reflectivity of 0.80 and emissivity of 0.85, leading to a substantial improvement in urban meteorology and thermal comfort compared to the unmitigated state. Notably, during heatwave episodes, the most significant computed reductions in energy flux were 181.3 Wm-2, 16.6 Wm-2, 56.3 Wm-2, and 251.9 Wm-2 for sensible heat, latent heat, ground storage, and net inflow radiation, respectively. Consequently, this led to decreases of 2.3 degrees C, 6.1 degrees C, 21.8 degrees C, and 1.9 degrees C in urban thermal parameters during peak hours (14:00 LT) for ambient temperature, surface temperature, roof surface temperature, and urban canopy temperature, respectively. The maximum drops in the planetary boundary layer (PBL) were 130.6 m, 1978.5 m, and 1010.3 m for 6:00 LT, 14:00 LT, and 18:00 LT, with an average of 870.3 m. Cool roofs demonstrated their potential to minimize thermal stress during heatwave periods, showcasing a maximum drop in the heat stress index (HSI) of up to 1.5 degrees C in the morning. Furthermore, outdoor thermal comfort could be significantly enhanced by lowering the universal thermal comfort index (UTCI) at the near surface, resulting in reductions of up to 1.8 degrees C during peak hours. On average, there was a reduction in UTCI between day and night of approximately 1.2 degrees C and 0.7 degrees C in densely populated urban areas. Additionally, the study evaluated 32 case studies that focused on cool roof strategies, revealing remarkably consistent findings that suggest a plausible justification. These findings provide a valuable framework for urban planners and policymakers considering the integration of cool roofs-based heat reduction technology at the city scale.
引用
收藏
页数:15
相关论文
共 38 条
  • [1] Evaluation of cool roof and vegetations in mitigating urban heat island in a tropical city, Singapore
    Li, Xian-Xiang
    Norford, Leslie K.
    URBAN CLIMATE, 2016, 16 : 59 - 74
  • [2] Outdoor thermal and visual perception of natural cool materials for roof and urban paving
    Rosso, Federica
    Pisello, Anna Laura
    Pignatta, Gloria
    Castaldo, Veronica Lucia
    Piselli, Cristina
    Cotana, Franco
    Ferrero, Marco
    DEFINING THE FUTURE OF SUSTAINABILITY AND RESILIENCE IN DESIGN, ENGINEERING AND CONSTRUCTION, 2015, 118 : 1325 - 1332
  • [3] Influence of the thermal insulation position in standard and cool roofs on their contribution to urban heating during heatwaves
    Chaumont, Maxime
    Hendel, Martin
    Filaine, Frederic
    Royon, Laurent
    ENERGY AND BUILDINGS, 2024, 324
  • [4] The impact of heatwaves on human perceived thermal comfort and thermal resilience potential in urban public open spaces
    Huang, Xizhen
    Yao, Runming
    Xu, Tiantian
    Zhang, Shaoxing
    BUILDING AND ENVIRONMENT, 2023, 242
  • [5] Cool Cities-Clean Cities? Secondary Impacts of Urban Heat Island Mitigation Strategies on Urban Air Quality
    Fallmann, Joachim
    Forkel, Renate
    Emeis, Stefan
    AIR POLLUTION MODELING AND ITS APPLICATION XXIV, 2016, : 371 - 375
  • [6] Thermal-energy analysis of roof cool clay tiles for application in historic buildings and cities
    Pisello, Anna Laura
    SUSTAINABLE CITIES AND SOCIETY, 2015, 19 : 271 - 280
  • [7] Review of Strategies for Thermal Efficiency in Landscape Planning of Cities for Conservation of Energy and Enhanced Climatic Resilience to Urban Warming
    Imam A.U.K.
    Banerjee U.K.
    Journal of The Institution of Engineers (India): Series A, 2017, 98 (3) : 327 - 335
  • [8] Urban wind energy with resilience approach for sustainable cities in tropical regions: A review
    Diaz, Alexander Vallejo
    Moya, Idalberto Herrera
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2024, 199
  • [9] A numerical study of the urban green roof and cool roof strategies' effects on boundary layer meteorology and ozone air quality in a megacity
    Zhong, Tianhao
    Zhang, Ning
    Lv, Mengyao
    ATMOSPHERIC ENVIRONMENT, 2021, 264
  • [10] A numerical study of the urban green roof and cool roof strategies’ effects on boundary layer meteorology and ozone air quality in a megacity
    Zhong, Tianhao
    Zhang, Ning
    Lv, Mengyao