The effect of preinduction cervical length measurement with three different ultrasonographic methods on predicting delivery time

被引:0
|
作者
Akar, Ayca Nazli [1 ,2 ]
Ceyhan, Venhar [1 ]
Cundubey, Cevat Rifat [1 ]
机构
[1] Kayseri City Educ & Res Hosp, Dept Obstet & Gynecol, Kayseri, Turkiye
[2] Kayseri City Educ & Res Hosp, Dept Obstet & Gynecol, TR-38072 Kayseri, Turkiye
关键词
cervical length; induction; transabdominal USG; transperineal USG; transvaginal USG; INDUCTION;
D O I
10.1111/jog.15820
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: This study aimed to evaluate the effect of preinduction cervical length (CL) measurement by transvaginal (TV), transperineal (TP), and transabdominal (TA) ultrasonography (USG) on the time of delivery and to compare these three sonographic methods in terms of superiority over one another.Methods: This study included TV, TP, and TA CL measurements in pregnant women who were planned to undergo induction of labor at 37 weeks' gestation or later. The correlations between the said three methods and BISHOP scores were evaluated. These three methods were compared in terms of superiority in predicting the time of delivery.Results: Pregnant women at 37-42 weeks' gestation undergoing labor induction were included, and all three methods were used for CL measurements. Three methods were correlated with each other (p < 0.001) and with BISHOP scores (p < 0.001).Conclusion: The correlation between all three methods and BISHOP scores indicates that TP and TA USG can be used instead of TV USG. On the other hand, while TA USG did not give a clear result in the accurate estimation of vaginal delivery time, TP, and TV USG gave both accurate and close results. When all these data are evaluated, it is concluded that TPU can be used safely instead of TVU, especially in patients receiving induction.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [1] Ultrasonographic measurement of cervical length in predicting mode of delivery after oxytocin induction
    Ali Yanik
    Çagri Gülümser
    Miraç Tosun
    Advances in Therapy, 2007, 24 : 748 - 756
  • [2] Ultrasonographic measurement of cervical length in predicting mode of delivery after oxytocin induction
    Yanik, Ali
    Gueluemser, Cagri
    Tosun, Mirac
    ADVANCES IN THERAPY, 2007, 24 (04) : 748 - 756
  • [3] Predicting mode of delivery using mid-pregnancy ultrasonographic measurement of cervical length
    Kalu, C. A.
    Umeora, O. U.
    Egwuatu, E. V.
    Okwor, A.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2012, 15 (03) : 338 - 343
  • [4] PREDICTION OF RISK FOR PRETERM DELIVERY BY ULTRASONOGRAPHIC MEASUREMENT OF CERVICAL LENGTH
    ANDERSEN, HF
    NUGENT, CE
    WANTY, SD
    HAYASHI, RH
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 163 (03) : 859 - 867
  • [5] EVALUATION OF THREATENED PRETERM DELIVERY BY TRANSVAGINAL ULTRASONOGRAPHIC MEASUREMENT OF CERVICAL LENGTH
    MURAKAWA, H
    UTUMI, T
    HASEGAWA, I
    TANAKA, K
    FUZIMORI, R
    OBSTETRICS AND GYNECOLOGY, 1993, 82 (05): : 829 - 830
  • [6] Ultrasonographic cervical length versus Bishop score for preinduction cervical assessment in parous women: a randomized clinical trial
    Ryu, Aeli
    Park, Kyo Hoon
    Lee, Sung Youn
    Jeong, Eun Ha
    Oh, Kyung Joon
    Kim, Ahra
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 208 (01) : S134 - S134
  • [7] Digital examination and transperineal ultrasonographic measurement of cervical length to assess risk of preterm delivery
    Önderoglu, LS
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1997, 59 (03) : 223 - 228
  • [8] Preinduction sonographic measurement of cervical length in the prediction of successful induction of labor
    Pandis, GK
    Papageorghiou, AT
    Ramanathan, VG
    Thompson, MO
    Nicolaides, KH
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (06) : 623 - 628
  • [9] Comparison of the Bishop score, sonographic measurement of cervical length and fibronectin assay in predicting time to delivery and type of delivery at term
    Rozenberg, P
    Goffinet, F
    Hessabi, M
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 1999, 183 (03): : 589 - 600
  • [10] Evaluating the risk of preterm delivery: A comparison of fetal fibronectin and transvaginal ultrasonographic measurement of cervical length
    Rozenberg, P
    Goffinet, F
    Malagrida, L
    Giudicelli, Y
    Perdu, M
    Houssin, I
    SageFemme
    Nisand, I
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 176 (01) : 196 - 199