Paced P-wave morphology templates to guide atrial tachycardia localization: A derivation and validation study

被引:0
|
作者
El Damaty, Ahmed [1 ]
Yahya, Dhaifallah [1 ]
El-Mowafy, Mahmoud [1 ]
Rizk, Hussien [1 ]
Sapp, John [2 ]
Parkash, Ratika [2 ]
Gardner, Martin [2 ]
Gray, Chris [2 ]
AbdelWahab, Amir [1 ,2 ]
机构
[1] Cairo Univ, Dept Cardiovasc Med Electrophysiol & Pacing Serv, 16 Oroba St, Cairo, Egypt
[2] Heart Rhythm Serv, QE Hlth Sci Ctr 2, Div Cardiol, Halifax, NS, Canada
来源
关键词
focal atrial tachycardia; P-wave morphology templates; pace-mapping; PREDICT SITE; ALGORITHM; ABLATION;
D O I
10.1111/pace.14774
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSurface ECG is a useful tool to guide mapping of focal atrial tachycardia (AT). ObjectivesWe aimed to construct 12-lead ECG templates for P-wave morphology (PWM) during endocardial pacing from different sites in both atria in patients with no apparent structural heart disease (derivation cohort), with the goal of creating a localization algorithm, which could subsequently be validated in a cohort of patients undergoing catheter ablation of focal AT (validation cohort). MethodsWe prospectively enrolled consecutive patients who underwent electrophysiology study, had no structural heart disease and no atrial enlargement. Atrial pacing, at twice diastolic threshold, was carried out at different anatomical sites in both atria. Paced PWM and duration were assessed. An algorithm was generated from the constructed templates of each pacing site. The algorithm was applied on a retrospective series of successfully ablated AT patients. Overall and site-specific accuracy were determined. ResultsDerivation cohort included 65 patients (25 men, age 37 & PLUSMN; 13 years). Atrial pacing was performed in 1025 sites in 61 patients (95%) in RA and in 15 patients (23%) in LA. The validation cohort included 71 patients (28 men, age 52 & PLUSMN; 19 years). AT were right atrial in 66.2%. The algorithm successfully predicted AT origin in 91.5% of patients (100% in LA and 87.2% in RA). It was off by one adjacent segment in the remaining 8.5%. ConclusionsA simple ECG algorithm based on paced PWM templates was highly accurate in localizing site of origin of focal AT in patients with structurally normal hearts.
引用
收藏
页码:1019 / 1031
页数:13
相关论文
共 50 条
  • [1] P-wave morphology in focal atrial tachycardia
    Chen, Peng-Sheng
    HEART RHYTHM, 2006, 3 (12) : 1511 - 1511
  • [2] P-Wave Morphology and the origin of Atrial Tachycardia
    Jiang Yongrong
    Zhou Xin
    Wei Yuejiao
    Wu Jine
    Ma Shuting
    Sun Chaofeng
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C121 - C121
  • [3] Incessant Atrial Tachycardia: P-Wave Morphology and Echocardiographic Characteristics
    Hashemi, Seyedeh-Neda
    Alizadehdiz, Abolfath
    Shani, Mahdiye Mehdinejad
    Shabani, Reyhane
    IRANIAN HEART JOURNAL, 2016, 17 (01): : 14 - 19
  • [4] P-WAVE MORPHOLOGY DURING AUTOMATIC ATRIAL TACHYCARDIA IN MAN
    TANG, CW
    SCHEINMAN, MM
    VANHARE, GF
    EPSTEIN, LM
    FITZPATRICK, AP
    LEE, RJ
    LESH, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A250 - A250
  • [5] P-Wave Morphology in Focal Atrial Tachycardia An Updated Algorithm to Predict Site of Origin
    Kistler, Peter M.
    Chieng, David
    Tonchev, Ivaylo R.
    Sugumar, Hariharan
    Voskoboinik, Aleksandr
    Schwartz, Lorin A.
    McLellan, Alex J.
    Prabhu, Sandeep
    Ling, Liang-Han
    Al-Kaisey, Ahmed
    Parameswaran, Ramanathan
    Anderson, Robert D.
    Lee, Geoffrey
    Kalman, Jonathan M.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (12) : 1547 - 1556
  • [6] P-WAVE CHANGES REFLECTING ATRIAL MORPHOLOGY
    MILLER, HI
    SPERTUS, I
    DISEASES OF THE CHEST, 1964, 46 (05): : 578 - 591
  • [7] P-wave morphology in focal atrial tachycardia - Development of an algorithm to predict the anatomic site of origin
    Kistler, Peter M.
    Roberts-Thomson, Kurt C.
    Haqqani, Haris M.
    Fynn, Simon P.
    Singarayar, Suresh
    Vohra, Jitendra. K.
    Morton, Joseph B.
    Sparks, Paul B.
    Kalman, Jonathan M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (05) : 1010 - 1017
  • [8] P-WAVE MORPHOLOGY IS UNAFFECTED BY ATRIAL SIZE: A STUDY IN HEALTHY ATHLETES
    Petersson, Richard
    Berge, Hilde M.
    Gjerdalen, Gard F.
    Carlson, Jonas
    Holmqvist, Fredrik
    Steine, Kjetil
    Platonov, Pyotr
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1650 - A1650
  • [9] P-Wave Morphology Is Unaffected by Atrial Size: A Study in Healthy Athletes
    Petersson, Richard
    Berge, Hilde M.
    Gjerdalen, Gard F.
    Carlson, Jonas
    Holmqvist, Fredrik
    Steine, Kjetil
    Platonov, Pyotr G.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2014, 19 (04) : 366 - 373
  • [10] A typical P-wave morphology in incessant atrial tachycardia originating from the right upper pulmonary vein
    Hegbom, F
    Hoff, PI
    Rossvoll, O
    Ohm, OJ
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (03) : 277 - 280