High-Resolution Enlarged Open-Bore Narrowband Magnetic Particle Imaging Based on Double-Layer Linear Scanning Structure

被引:3
|
作者
Bai, Shi [1 ]
Li, Tianshu [1 ]
Li, Kewen [1 ]
Gai, Lingke [1 ]
Du, Zhongzhou [2 ]
Du, Cheng [3 ]
Zhang, Wei [3 ]
Yoshida, Takashi [4 ]
Gu, Yumei [5 ]
机构
[1] Shenyang Univ Technol, Dept Informat Engn, Shenyang 110870, Peoples R China
[2] Zhengzhou Univ Light Ind, Dept Comp & Commun Engn, Zhengzhou 450066, Peoples R China
[3] Gen Hosp Northern Theater Command, Dept Oncol, Shenyang 110016, Peoples R China
[4] Kyushu Univ, Dept Elect Engn, Fukuoka 8190395, Japan
[5] Capital Med Univ, Beijing Chao Yang Hosp, Dept Pathol, Beijing 100020, Peoples R China
基金
中国国家自然科学基金;
关键词
Superparamagnetic iron oxide nanoparticles; Spatial resolution; Image reconstruction; Harmonic analysis; Magnetic resonance imaging; Tomography; Three-dimensional displays; Enlarged field of view (FOV); magnetic particle imaging (MPI); narrowband MPI; open-bore MPI; superparamagnetic iron oxide nanoparticles (SPIONs);
D O I
10.1109/TMAG.2023.3285847
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a novel high-resolution open-bore narrowband magnetic particle imaging (MPI) system for big animal and future clinical usage. Optimized strength and direction of excitation field was invested for enlarged field of view (FOV), and a 4 T/m gradient field and its linear scanning trajectory were formed by 16 square coils without coupling to excitation, forming a maximum 120 x 120 mm open bore FOV. Furthermore, a new differential pickup structure consisted of multi Helmholtz excitation and pickup coils away from the FOV was proposed in order to suppress the system noises, which was very important for the limited coil setting space in open-bore MPI. The new differential structure contributed significantly to improve the signal-to-noise ratio (SNR) as high as about 100 dB without loss of harmonic signals. Several homemade resonant circuits, filters, and lock-in amplifier were used to constitute the high-precision signal acquisition system. Experimental results showed that the detection limit of the system was 1 ug Fe of Resovist sample with a spatial resolution of 1 mm after reconstruction, satisfying many clinical needs, such as drug delivery and bedside monitoring.
引用
收藏
页数:5
相关论文
共 10 条
  • [1] Double-layer coating for high-resolution low-temperature scanning electron microscopy
    Walther, P.
    Wehrli, E.
    Hermann, R.
    Muller, M.
    Journal of Microscopy, 1995, 179 (03): : 229 - 237
  • [2] High-resolution magnetic imaging based on scanning probe techniques
    Hartmann, U
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1996, 157 : 545 - 549
  • [3] DOUBLE-LAYER COATING FOR HIGH-RESOLUTION LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY
    WALTHER, P
    WEHRLI, E
    HERMANN, R
    MULLER, M
    JOURNAL OF MICROSCOPY-OXFORD, 1995, 179 : 229 - 237
  • [4] High-Resolution Scintillation Screen with Double-Layer Structure Based on Crosstalk Suppression by Interface Total Reflection
    An Kang
    Li Wenfang
    Duan Xiaojiao
    Du Yu
    Zhou Rifeng
    Wang Jue
    ACTA OPTICA SINICA, 2022, 42 (22)
  • [5] HIGH-RESOLUTION DOUBLE-LAYER RESIST SYSTEM USING NEW SILICONE BASED NEGATIVE RESIST (SNR)
    MORITA, M
    TANAKA, A
    IMAMURA, S
    TAMAMURA, T
    KOGURE, O
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1983, 22 (10): : L659 - L660
  • [6] Sequential Scan-Based High-Resolution 3-D Open-Sided Magnetic Particle Imaging System
    He, Jie
    Zhang, Haoran
    Lei, Siao
    Li, Guanghui
    Li, Yimeng
    Zhu, Tao
    Qian, Zhumei
    Xiong, Fei
    Feng, Yuan
    An, Yu
    Tian, Jie
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 12
  • [7] MPIGAN: An end-to-end deep based generative framework for high-resolution magnetic particle imaging reconstruction
    Zhao, Jing
    Shen, Yusong
    Liu, Xinyi
    Hou, Xiaoyuan
    Ding, Xuetong
    An, Yu
    Hui, Hui
    Tian, Jie
    Zhang, Hui
    MEDICAL PHYSICS, 2024, 51 (08) : 5492 - 5509
  • [8] High-Scanning-Rate and Wide-Scanning-Angle Leaky-Wave Antenna Based on Double-Layer Slow-Wave Structure
    Zhang, Hong-Hao
    Li, Rui
    Ren, Jian
    Du, Xiaoyu
    Zhang, Chenghao
    Sun, Xiao-Yuan
    Yin, Yingzeng
    Shen, Ming
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2023, 22 (09): : 2145 - 2149
  • [9] High-resolution backscatter electron detection of cell surface molecules on human platelets using the double-layer coating method and cryo field emission scanning electron microscopy
    Erlandsen, SL
    Bittermann, A
    Krumweide, M
    Nelson, RD
    Chen, Y
    White, JG
    SCANNING, 1997, 19 (05) : 356 - 360
  • [10] ANTIBIOTICS OF OSTREOGRYCIN COMPLEX .3. STRUCTURE OF OSTREOGRYCIN A. EVIDENCE BASED ON NUCLEAR MAGNETIC DOUBLE RESONANCE EXPERIMENTS AND HIGH-RESOLUTION MASS SPECTROMETRY
    KINGSTON, DG
    TODD
    WILLIAMS, DH
    JOURNAL OF THE CHEMICAL SOCIETY C-ORGANIC, 1966, (19): : 1669 - &