Impurities removal from acidic solution of nickel cobalt complex hydroxide using pulsed disc and doughnut column

被引:0
|
作者
Wang, Chi [1 ,2 ,3 ]
Tan, Boren [3 ]
Wang, Chenye [3 ,4 ]
Wang, Yong [3 ,4 ]
Xing, Peng [3 ,4 ]
Li, Huiquan [3 ,4 ]
Gui, Xiahui [1 ]
Yang, Jianguo [1 ]
Guan, Xue [3 ]
机构
[1] China Univ Min & Technol, State Key Lab Coking Coal Resources Green Exploita, Xuzhou 221116, Peoples R China
[2] China Univ Min & Technol, Sch Chem Engn & Technol, Xuzhou 221116, Peoples R China
[3] Chinese Acad Sci, Inst Proc Engn, Natl Engn Res Ctr Green Recycling Strateg Met Reso, CAS Key Lab Green Proc & Engn, Beijing 100090, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulsed disc and doughnut column; Nickel cobalt complex hydroxide; Impurities removal; Mass transfer; Solvent extraction; DISPERSED-PHASE HOLDUP; DROP SIZE; EXTRACTION; PREDICTION;
D O I
10.1016/j.mineng.2024.108638
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, a 30 mm diameter pulsed disc and doughnut solvent extraction column was used for impurities removal from nickel cobalt complex hydroxide acid solution by solvent extraction. The effects of dispersed phase velocity, continuous phase velocity and pulse intensity on drop diameter, dispersed phase holdup and mass transfer were investigated. The results show that the drop size decreases gradually, and the dispersed phase holdup decreased initially and then increased with the increase of pulse intensity. The dispersed phase holdup increases with the increase of dispersed phase velocity but is independent of the continuous phase velocity. The experimental data of this study are predicted by correlations with regressed parameters. The average absolute relative error of drop size and dispersed phase holdup were 10.07 % and 18.28 %. With the increase of pulse intensity, the extraction efficiency of impurities decreased firstly and then increased. The number of mass transfer units and the height of mass transfer unit were calculated. The trend of number of mass transfer units of impurities are similar to extraction efficiency. Mass transfer results indicate that pulsed disc and doughnut column can be applied to the nickel cobalt complex hydroxide acid solution-P204/kerosene system.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Investigation of hydrodynamics behavior in a gas-agitated disc and doughnut column for solvent extraction with application to impurity removal from mixed nickel-cobalt hydroxide precipitate
    Wang, Chi
    Xu, Dongbing
    Tan, Boren
    Chang, Chao
    Wang, Chenye
    Wang, Yong
    Xing, Peng
    Li, Huiquan
    Gui, Xiahui
    Yang, Jianguo
    HYDROMETALLURGY, 2025, 233
  • [2] Prediction of Flooding Characteristic in Pulsed Disc and Doughnut Extraction Column Using LASSO Method
    Jin, Lei
    He, Hui
    Zhou, Yu
    Hou, Hongguo
    Zhang, Meng
    Gao, Yang
    NUCLEAR TECHNOLOGY, 2024, 210 (08) : 1392 - 1413
  • [3] Extraction of samarium and gadolinium from aqueous nitrate solution with D2EHPA in a pulsed disc and doughnut column
    Torkaman, R.
    Safdari, J.
    Torab-Mostaedi, M.
    Moosavian, M. A.
    Asadollahzadeh, M.
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2015, 48 : 18 - 25
  • [4] Removal of Impurities from Nickel and Cobalt in Mixed Hydroxide Precipitate with Solvent Extraction Using Di(2-Ethylhexyl) Phosphoric Acid
    Andriyanto, V. D.
    Ichlas, Z. T.
    Mubarok, M. Z.
    MINERAL PROCESSING AND EXTRACTIVE METALLURGY REVIEW, 2024,
  • [5] Study of mass transfer and emphasis on pulsed and non-pulsed conditions for implementing cobalt extraction in the pilot plant column with disc and doughnut configuration
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 161
  • [6] Removal of nickel from aqueous solution using cathodic deposition of nickel hydroxide at a modified electrode
    Liu, YaoXing
    Wu, XiaoYun
    Yuan, DongXing
    Yan, JunMei
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2013, 88 (12) : 2193 - 2200
  • [7] Column Adsorption Studies on Nickel and Cobalt Removal from Aqueous Solution Using Native and Biochar Form of Tectona grandis
    Vilvanathan, Sowmya
    Shanthakumar, S.
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2017, 36 (04) : 1030 - 1038
  • [8] Removal of copper from acidic nickel chloride solution with nickel matte
    Imamura, Masaki
    Tsuchida, Naoyuki
    Matsugi, Nobuo
    Metallurgical Review of MMIJ (Mining and Metallurgical Institute of Japan), 1997, 14 (01): : 53 - 68
  • [9] Removal of ethylenediaminetetraacetic acid and its cobalt complex by layered double hydroxide/titanium dioxide from aqueous solution
    Sheha, Reda R.
    Harb, Ahmed H.
    El-sayed, Ibrahim El-T.
    Someda, Hanan H.
    DESALINATION AND WATER TREATMENT, 2016, 57 (35) : 16466 - 16472
  • [10] Leaching of Nickel and Cobalt from a Mixed Nickel-Cobalt Hydroxide Precipitate Using Organic Acids
    Hussaini, Shokrullah
    Tita, Angela Manka
    Kursunoglu, Sait
    Kaya, Muammer
    Chu, Pengbo
    MINERALS, 2024, 14 (03)