Microfluidic viscometer using capillary pressure sensing

被引:2
|
作者
Kang, Yang Jun [1 ]
机构
[1] Chosun Univ, Dept Mech Engn, 309 Pilmun Daero, Gwangju 61452, South Korea
关键词
BLOOD-VISCOSITY; FLOW; QUANTIFICATION; COST;
D O I
10.1063/5.0176229
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Blood viscosity is considered as a vital determinant of the efficiency of blood flow in blood-vessel networks. The coflowing method is considered as a promising technique for measuring blood viscosity. However, it requires two precise syringe pumps to supply two fluids (i.e., the reference fluid and blood), calibration in advance, and long waiting time for securing steady blood flow. To solve these problems, a single syringe pump is adopted to supply blood into a microfluidic device without requiring a reference fluid. Two key parameters-fluidic resistance and compliance coefficient-are suggested and obtained by analyzing the fluid velocities in a microfluidic channel and calculating the air pressure in the air compliance unit. Using a discrete fluidic circuit model, the pressure difference is analytically derived and utilized as the nonlinear regression formula. The two key parameters are then obtained through nonlinear regression analysis. According to experimental results, the air cavity and flow rate contribute to increasing the compliance coefficient. The fluidic resistance increases significantly at higher concentrations of glycerin solution ranging from 20% to 50%. The proposed method underestimates the values by approximately 27.5% compared with the previous method. Finally, the proposed method is adopted to detect the effects of hematocrit and red blood cell sedimentation in the driving syringe based on two vital parameters. Regarding the fluidic resistance, the normalized difference between the proposed and previous methods is less than 10%. Therefore, two key parameters can be considered as effective for quantitatively monitoring the hematocrit variation in blood flow. In conclusion, from a biomechanical perspective, the proposed method is highly promising for quantifying blood flow in a microfluidic channel.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Analysis of non-Newtonian liquids using a microfluidic capillary viscometer
    Srivastava, N
    Burns, MA
    ANALYTICAL CHEMISTRY, 2006, 78 (05) : 1690 - 1696
  • [2] Design of microfluidic viscometer based on pressure estimation
    Kang, Dongkuk
    Song, Jae Min
    Yeom, Eunseop
    JOURNAL OF VISUALIZATION, 2019, 22 (01) : 25 - 34
  • [3] Design of microfluidic viscometer based on pressure estimation
    Dongkuk Kang
    Jae Min Song
    Eunseop Yeom
    Journal of Visualization, 2019, 22 : 25 - 34
  • [4] Blood viscosity measurements using a pressure-scanning capillary viscometer
    Sehyun Shin
    Do-Young Keum
    Yun Hee Ku
    KSME International Journal, 2002, 16 : 1719 - 1724
  • [5] Measurement of blood viscosity using a pressure-scanning capillary viscometer
    Shin, S
    Ku, Y
    Park, MS
    Suh, JS
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2004, 30 (3-4) : 467 - 470
  • [6] A METHOD FOR PRODUCING HIGHLY ORIENTED POLYETHYLENE USING A PRESSURE CAPILLARY VISCOMETER
    SOUTHERN, JH
    PORTER, RS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (03): : 377 - &
  • [7] Blood viscosity measurements using a pressure-scanning capillary viscometer
    Shin, S
    Keum, DY
    Ku, YH
    KSME INTERNATIONAL JOURNAL, 2002, 16 (12): : 1719 - 1724
  • [8] A COMPACT, HIGH-PRESSURE CAPILLARY VISCOMETER
    RIPPLE, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (05): : 3153 - 3155
  • [9] IMPROVED HIGH PRESSURE CAPILLARY TUBE VISCOMETER
    EAKIN, BE
    ELLINGTON, RT
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1959, 216 : 85 - 91
  • [10] A CAPILLARY VISCOMETER WITH CONTINUOUSLY VARYING PRESSURE HEAD
    MARON, SH
    KRIEGER, IM
    SISKO, AW
    JOURNAL OF APPLIED PHYSICS, 1954, 25 (08) : 971 - 976