Safety and Efficacy of an Implantable Cardioverter Defibrillator (ICD) in the Detection and Prevention of Cardiac Arrhythmia - A Systematic Review

被引:1
|
作者
Tran, Hadrian Hoang-Vu [1 ]
Sherpa, Mingma L. [2 ]
Shrestha, Nilasma [3 ]
Ravi, Niriksha [4 ]
Choday, Silpa [1 ]
Kumar, Vivig Shantha [1 ]
Anil, K. C. [5 ]
Parisapogu, Anusha [1 ,6 ]
Ojinna, Blessing T. [7 ,8 ]
Mohammed, Lubna [1 ]
机构
[1] Calif Inst Behav Neurosci & Psychol, Internal Med, Fairfield, CA 94534 USA
[2] Calif Inst Behav Neurosci & Psychol, Neurol, Fairfield, CA 94534 USA
[3] Calif Inst Behav Neurosci & Psychol, Med, Fairfield, CA 94534 USA
[4] Calif Inst Behav Neurosci & Psychol, Internal Med & Neurol, Fairfield, CA USA
[5] Calif Inst Behav Neurosci & Psychol, Internal Med & Family Med, Fairfield, CA 94534 USA
[6] Mayo Clin, Infect Dis, Rochester, MN USA
[7] Calif Inst Behav Neurosci & Psychol, Internal Med & Pediat, Fairfield, CA USA
[8] Univ Nigeria Nsukka, Med, Enugu, Nigeria
关键词
life-threatening arrhythmia; intervention cardiology; cardiology devices; implantable cardiac defibrillator (icd); safety and efficacy; DISCRIMINATION; EXPERIENCE; SETTINGS;
D O I
10.7759/cureus.48471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable cardioverter defibrillators (ICD) have been recommended as an effective therapy in treating sudden cardiac deaths. This study evaluates the safety and efficacies of ICDs in detecting arrhythmias. Different ICDs, such as the transvenous cardioverter defibrillator (TV-ICD) and the subcutaneous implantable cardioverter defibrillator (S-ICD), are used. This systematic review identified Embase, PubMed, Medical Literature Analysis and Retrieval System Online (MEDLINE), and Web of Science as the primary electronic databases for research. Supplementation of the available articles for the review was done using Google Scholar. The population, exposure, control, outcome, and studies (PECOS) criteria were used in this study. The quality of the included studies was assessed using the Critical Appraisal Skills Program (CASP) standard checklist. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used in this systematic review. Two researchers conducted the extraction of data. A pre-designed Excel worksheet (Microsoft, Redmond, Washington) was used in the recording of extracted data. Eight studies were identified for use in this systematic review. Safety of the ICDs was observed with the minimum number of reported inappropriate shocks. Studies conducted identified that women had a lower number of incidences when a long detection setting by sex was conducted. Strategic programming of ICDs was noted as effective in lowering the levels of mortality. Studies claimed that the reduction of inappropriate shocks were important in the reduction of myocardial damage, which resulted in the mortality rate among the patients decreasing. Having high cutoff rates and long intervals for detection in ICD programming was noted to help in reducing ICD therapy intervention among patients. Differences among the male and female populations were inconsequential in the efficacy and safety of ICDs. Their effectiveness in sensitivity, pacing success, and defibrillation success were high and very significant. ICDs were safe in their use in the detection of arrhythmias.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Efficacy and safety of the subcutaneous implantable cardioverter defibrillator: a systematic review
    Chue, Colin Dominic
    Kwok, Chun Shing
    Wong, Chun Wai
    Patwala, Ashish
    Barker, Diane
    Zaidi, Amir
    Mamas, Mamas A.
    Cunnington, Colin
    Ahmed, Fozia Z.
    HEART, 2017, 103 (17) : 1315 - 1322
  • [2] Implantable cardioverter-defibrillator in patients with inherited arrhythmia syndromes: A systematic review
    Medeiros, Paulo
    Santos, Maria
    Arantes, Carina
    Pereira, Vitor Hugo
    Rocha, Sergia
    HEART & LUNG, 2023, 60 : 1 - 7
  • [3] Dual chamber arrhythmia detection in the implantable cardioverter defibrillator
    Dijkman, B
    Wellens, HJJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (10) : 1105 - 1115
  • [4] Indications for an implantable cardioverter defibrillator (ICD)
    Aizawa, Y
    Chinushi, M
    Washizuka, T
    INTERNAL MEDICINE, 2004, 43 (05) : 360 - 367
  • [5] Implantable cardioverter defibrillator (ICD) in children
    Eicken, A
    Kolb, C
    Lange, S
    Brodherr-Heberlein, S
    Zrenner, B
    Schreiber, C
    Hess, J
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 107 (01) : 30 - 35
  • [7] Safety and efficacy of subcutaneous implantable cardioverter defibrillator (S-ICD): a single centre experience
    Doyle, C.
    Byrne, L.
    Low, R.
    Galvin, J.
    HEART, 2023, 109 (SUPPL_6) : A11 - A11
  • [8] Efficacy and Safety of an Extravascular Implantable Cardioverter-Defibrillator
    Di Lellis, Maddalena Angela
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2023, 148 (04) : 148 - 148
  • [9] Efficacy and Safety of an Extravascular Implantable Cardioverter-Defibrillator
    Friedman, Paul
    Murgatroyd, Francis
    Boersma, Lucas V. A.
    Manlucu, Jaimie
    O'Donnell, David
    Knight, Bradley P.
    Clementy, Nicolas
    Leclercq, Christophe
    Amin, Anish
    Merkely, Bela P.
    Birgersdotter-Green, Ulrika M.
    Chan, Joseph Y. S.
    Biffi, Mauro
    Knops, Reinoud E.
    Engel, Greg
    Carvajal, Ignacio Munoz
    Epstein, Laurence M.
    Sagi, Venkata
    Johansen, Jens B.
    Sterlinski, M.
    Steinwender, Clemens
    Hounshell, Troy
    Abben, Richard
    Thompson, Amy E.
    Wiggenhorn, Christopher
    Willey, Sarah
    Crozier, Ian
    NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (14): : 1292 - 1302
  • [10] Subcutaneous implantable cardioverter-defibrillator (S-ICD) for secondary prevention of sudden cardiac death
    Kempa, Maciej
    Budrejko, Szymon
    Raczak, Grzegorz
    ARCHIVES OF MEDICAL SCIENCE, 2016, 12 (05) : 1179 - 1180