Energy, economic, and environmental (3E) performance assessment, comparison, and analysis of airport cargo terminal microgrid system under the islanded and grid-connected modes

被引:5
|
作者
Zeng, Chao [1 ]
Luo, Jianing [1 ]
Yuan, Yanping [1 ]
Haghighat, Fariborz [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Peoples R China
[2] Concordia Univ, Dept Bldg Civil & Environm Engn BCEE, Montreal, PQ, Canada
来源
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Airport cargo terminal; 3E performance assessment; Microgrid system flexibility quantification; Operating mode judgment; Load classification; WIND POWER; STORAGE; RELIABILITY; BATTERY;
D O I
10.1016/j.jobe.2023.108270
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Microgrids, which can be grid-connected or isolated, may experience dependability issues as a result of intermittent renewable energy. The implementation of a hybrid renewable energy system (HRES) could alleviate this problem but is still a challenging task because of its interference, uncertain, and unpredictable nature. Currently, the absence of comprehensive assessment impedes large-scale applications. In this study, a novel 3E assessment method-based complete quantitative assessment is suggested and inventively integrated with a newly proposed triangle evaluation scheme. Loads of an airport cargo terminal, which are used to test the assessment approach, are classified into critical and non-critical categories according to their necessity. The microgrid system flexibility is considered by the trade-off of non-critical loads. Results show that the assessment method is more intuitive in quantifying the system's performance. The Levelized Cost of Energy (LCOE) in the islanded mode is lower than the current electricity price (from 0.5407 to 0.5439 CNY/kWh) and the annual carbon emission is reduced to one-third of that in the grid-connected mode. Its flexibility can effectively reduce dependence on backup power gener-ation, where the daily peak shedding increases from 217.88 kW to 555.04 kW and daily hours without charging from 6.7 h to 8.9 h. The carbon emission decreases by 32 % considering the impacts of the system flexibility. Besides, the critical distance exists when the LCOE exceeds the current market electricity price.
引用
收藏
页数:18
相关论文
共 33 条
  • [1] Energy Management of AC-DC Microgrid under Grid-connected and Islanded Modes
    Tummuru, Narsa Reddy
    Ukil, Abhisek
    Gooi, H. B.
    Verma, Arun Kumar
    Kollimalla, Sathish Kumar
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 2040 - 2045
  • [2] Energy assessment and economic sensitivity analysis of a grid-connected photovoltaic system
    Cui, Yuanlong
    Zhu, Jie
    Meng, Fanran
    Zoras, Stamatis
    McKechnie, Jon
    Chu, Junze
    RENEWABLE ENERGY, 2020, 150 : 101 - 115
  • [3] Energy, economic and environmental performance assessment of a grid-tied rooftop system in different cities of India based on 3E analysis
    Saxena, Anupama Khare
    Saxena, Seema
    Sudhakar, K.
    CLEAN ENERGY, 2021, 5 (02): : 288 - 301
  • [4] Techno-Economic and Environmental Analysis of a Grid-Connected Photovoltaic Energy System
    Memar, Mohammad-Reza
    Moazzami, Majid
    Shahinzadeh, Hossein
    Fadaei, Davoud
    2017 CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2017, : 124 - 130
  • [5] Synthetical control strategy for smooth switching between grid-connected and islanded operation modes of microgrid based on energy storage system
    Zhao, Dongmei
    Zhang, Nan
    Liu, Yanhua
    Zhang, Xu
    Dianwang Jishu/Power System Technology, 2013, 37 (02): : 301 - 306
  • [6] Energetic, economic and environmental (3E) analyses and LCOE estimation of three technologies of PV grid-connected systems under different climates
    Allouhi, A.
    Saadani, R.
    Buker, M. S.
    Kousksou, T.
    Jamil, A.
    Rahmoune, M.
    SOLAR ENERGY, 2019, 178 : 25 - 36
  • [7] Grid-connected PV systems installed on institutional buildings: Technology comparison, energy analysis and economic performance
    Allouhi, A.
    Saadani, R.
    Kousksou, T.
    Saidur, R.
    Jamil, A.
    Rahmoune, M.
    ENERGY AND BUILDINGS, 2016, 130 : 188 - 201
  • [8] Comprehensive Energy-Econo-Enviro (3E) Analysis of Grid-Connected Household Scale Wind Turbines in Qatar
    Teshnizi, Ehsan Abbasi
    Jahangiri, Mehdi
    Shamsabadi, Akbar Alidadi
    Pomares, Luis Martin
    Mostafaeipour, Ali
    Assad, Mamdouh El Haj
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2021, 15 (02): : 215 - 231
  • [9] Energy and economic efficiency performance assessment of a 28 kWp photovoltaic grid-connected system under desertic weather conditions in Algerian Sahara
    Sahouane, Nordine
    Dabou, Rachid
    Ziane, Abderrezzaq
    Necaibia, Ammar
    Bouraiou, Ahmed
    Rouabhia, Abdelkrim
    Mohammed, Blal
    RENEWABLE ENERGY, 2019, 143 : 1318 - 1330
  • [10] ENERGY and ENVIRONMENTAL PERFORMANCE ANALYSIS of GRID-CONNECTED PHOTOVOLTAIC SYSTEMS under SIMILAR OUTDOOR CONDITIONS in the SAHARAN ENVIRONMENT
    Deriche M.A.
    Hafaifa A.
    Tahri A.
    Mohammedi K.
    Tahri F.
    Diagnostyka, 2020, 21 (02): : 13 - 23