Cross-Radiometric Calibration and NDVI Application Comparison of FY-4A/AGRI Based on Aqua-MODIS

被引:0
|
作者
He, Xiaohui [1 ]
Li, Hongli [1 ]
Zhou, Guangsheng [1 ,2 ]
Tian, Zhihui [1 ]
Wu, Lili [1 ]
机构
[1] Zhengzhou Univ, Sch Earth Sci & Technol, Zhengzhou 450001, Peoples R China
[2] Chinese Acad Meteorol Sci, State Key Lab Severe Weather, Beijing 100081, Peoples R China
关键词
cross calibration; MODIS; FY-4A; spectral correction; geometric matching; NDVI; REFLECTIVE SOLAR BANDS; CONSISTENCY;
D O I
10.3390/rs15235454
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To enhance the accuracy and stability of FY-4A/AGRI detection data, the MODIS, with highly accurate onboard calibration, is selected as the reference sensor for cross-radiation calibration calculations. The following are the data selection conditions: full considered time, observation geometries, field angles, cloud cover, etc. FY-4A/AGRI and Aqua-MODIS image data are selected as matching sample region locations, where the time difference between the observations for the same ground object is less than 15 min, the satellite zenith angle is less than 30 degrees, and the field angle difference is less than 0.01. The 245 collected reflectance spectral curves are convolved with the spectral response functions of the two sensors, and the spectral band adjustment factors of the corresponding bands are calculated for spectral correction purposes. The cross-calibration coefficients for the red and near-infrared bands are calculated by linearly fitting the simulated top of the atmosphere reflectance values and digital number values from the AGRI sensor in a homogeneous area. In this paper, 16 cross-calibration calculations are performed on FY-4A/AGRI image data from August 2018 to September 2020, and the results are compared with the original calibration coefficients to test the feasibility of the proposed method. Additionally, 31 cross-calibration calculations are performed on image data from October 2020 to December 2022 to study the resulting AGRI sensor quality and performance changes. The NDVI of the FY-4A/AGRI image data was calculated before and after the cross-radiometric calibration using the maximum synthesis method. Additionally, the NDVI of the MODIS image data was compared and analyzed from three aspects: time, space, and the change trend. The results show that the spectral band adjustment factor calculated using the reflectance spectral curves of the ground objects in this paper can effectively correct for the spectral differences between the two sensors. Sixteen cross-calibration coefficients are less than 5.2% different from the original calibration coefficients, which fully proves the feasibility of the method used in this paper. All of the cross-calibration results show that the AGRI sensors have a certain degree of attenuation in the red and near-infrared bands, and the annual attenuation rates are approximately 1.37% and 2.55%, respectively. Cross-radiometric calibration has further improved the quality of the NDVI in FY-4A/AGRI imagery, enhancing the precision of its data application.
引用
收藏
页数:29
相关论文
共 8 条
  • [1] Radiometric Performance Evaluation of FY-4A/AGRI Based on Aqua/MODIS
    Zhong, Bo
    Ma, Yingbo
    Yang, Aixia
    Wu, Junjun
    SENSORS, 2021, 21 (05) : 1 - 11
  • [2] Assessing Radiometric Calibration of FY-4A/AGRI Thermal Infrared Channels Using CrIS and IASI
    He, Xingwei
    Xu, Na
    Feng, Xiaohu
    Hu, Xiuqing
    Xu, Hanlie
    Peng, Yi
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [3] On-orbit installation matrix calibration and its application on AGRI of FY-4A
    Chen, Boyang
    Li, Xiaoyan
    Zhang, Gaoxiong
    Guo, Qiang
    Wu, Yapeng
    Wang, Baoyong
    Chen, Fansheng
    JOURNAL OF APPLIED REMOTE SENSING, 2020, 14 (02)
  • [4] Cross Calibration of SDGSAT-1/TIS ThermalInfrared Bands With FY-4A/AGRI
    Zhu, Min
    Zhao, Xue
    Zou, Lu
    Chen, Fansheng
    Hu, Zhuoyue
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 6233 - 6240
  • [5] Assessment and calibration of FY-4A AGRI total precipitable water products based on CMONOC
    Liu, Xiao
    Wang, Yong
    Huang, Jing
    Yu, Tengli
    Jiang, Nuohan
    Yang, Jun
    Zhan, Wei
    ATMOSPHERIC RESEARCH, 2022, 271
  • [6] 基于AQUA/MODIS的FY-4A/AGRI传感器热红外通道交叉辐射定标方法
    刘佳欣
    高彩霞
    杨治纬
    邱实
    赵永光
    马灵玲
    钱永刚
    无线电工程, 2021, 51 (12) : 1373 - 1381
  • [7] Scene-based Cross-comparison of SNPP-VIIRS and Aqua-MODIS over Oceanic Waters
    Pahlevan, Nima
    Lee, Zhongping
    Lawson, Adam
    Arnone, Robert
    EARTH OBSERVING SYSTEMS XVIII, 2013, 8866
  • [8] Radiometric Cross-Calibration of GF-4/IRS Based on MODIS Measurements
    Zhou, Xiang
    Feng, Duo
    Xie, Yong
    Tao, Zui
    Lv, Tingting
    Wang, Jin
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2021, 14 : 6807 - 6814