Point Shear Wave Elastography by ElastPQ for Fibrosis Screening in Patients with NAFLD: A Prospective, Multicenter Comparison to Vibration-Controlled Elastography

被引:15
|
作者
Bauer, David J. M. [1 ,2 ]
Matic, Vladimir [3 ]
Mare, Ruxandra [4 ]
Maiocchi, Laura [5 ]
Chromy, David [1 ,2 ]
Muellner-Bucsics, Theresa [1 ,2 ]
Mandorfer, Mattias [1 ,2 ]
Mustapic, Sandra [3 ]
Sporea, Ioan [6 ]
Ferraioli, Giovanna [5 ]
Grgurevic, Ivica [3 ]
Reiberger, Thomas [1 ,2 ,7 ]
机构
[1] Med Univ Vienna, Vienna Hepat Hemodynam Lab, Vienna, Austria
[2] Med Univ Vienna, Div Gastroenterol & Hepatol, Vienna, Austria
[3] Univ Zagreb, Sch Med, Zagreb, Croatia
[4] Univ Med & Pharm Victor Babes Timisoara, Ctr Adv Res Gastroenterol & Hepatol, Div Gastroenterol & Hepatol, Timisoara, Romania
[5] Univ Pavia, Dept Clin Surg Diagnost & Pediat Sci, Pavia, Italy
[6] Univ Med & Pharm Victor Babes Timisoara, Ctr Adv Res Gastroenterol & Hepatol, Dept Internal Med 2, Div Gastroenterol & Hepatol, Timisoara, Romania
[7] Med Univ Vienna, Christian Doppler Lab Portal Hypertens & Liver Fi, Vienna, Austria
来源
ULTRASCHALL IN DER MEDIZIN | 2023年 / 44卷 / 02期
关键词
Abdomen; Gastrointestinal Tract; Point of care; Physics and Technology; FATTY LIVER-DISEASE; DIAGNOSIS;
D O I
10.1055/a-1724-7289
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Background Since nonalcoholic fatty liver disease (NAFLD) has become the leading cause of liver disease in the Western world, clinicians need reliable noninvasive tools for the identification of NAFLD-associated fibrosis. Limited evidence on the performance of the novel shear wave elastography technique Elast-PQ (EPQ) in NAFLD is available. Method In this prospective, European multinational study we assessed the diagnostic accuracy of EPQ using vibration-controlled transient elastography (VCTE) as a reference standard. Results Among 353 NAFLD patients, 332 (94.1%) fulfilled reliability criteria of VCTE and EPQ (defined by IQR/median <= 0.3; 41.3% female, mean age: 59 [IQR: 16.5], mean BMI: 29.0 (7.1)). 4/353 (1.1%) and 17/353 (4.8%) had unreliable VCTE and EPQ measurements, respectively. VCTE-based NAFLD fibrosis stages were F0/F1: 222(66.9%), F2: 41 (12.3%), F3: 30 (9.1%), F4: 39 (11.7%). We found a strong correlation (Pearson R=0.87; p<0.0001) and concordance (Lin's concordance correlation coefficient =0.792) of EPQ with VCTE. EPQ was able to identify NAFLD-fibrosis risk with the following EPQ cutoffs: >= 6.5 kPa for significant fibrosis (>= F2) (>= 1.47 m/s; sensitivity: 78%; specificity: 95%; AUROC: 0.94), >= 6.9 kPa for advanced fibrosis (>= F3) (>= 1.52 m/s; sens.: 88%, spec.: 89%; AUROC: 0.949), and >= 10.4 kPa for cirrhosis (F4) (>= 1.86 m/s; sens.: 87%; spec.: 94%; AUROC: 0.949). Conclusion The point shear wave elastography technique EPQ shows excellent correlation to and concordance with VCTE. EPQ can reliably exclude NAFLD fibrosis <6.0 kPa (<1.41 m/s) and indicate a high risk of advanced fibrosis >= 10.4 kPa (>= 1.86 m/s).
引用
收藏
页码:169 / 178
页数:10
相关论文
共 50 条
  • [1] Point shear wave elastography by ElastPQ accurately stages hepatic fibrosis in patients with NAFLD: A prospective, multicentric study
    Bauer, David J. M.
    Matic, Vladimir
    Mare, Ruxandra
    Maiocchi, Laura
    Chromy, David
    Bucsics, Theresa
    Mustapic, Sanda
    Sporea, Ioan
    Ferraioli, Giovanna
    Reiberger, Thomas
    Grgurevic, Ivica
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E756 - E757
  • [2] Comparison of point-shear wave elastography (ElastPQ) and fibroscan transient elastography (F-TE) for liver fibrosis staging in patients with NAFLD
    Roccarina, Davide
    Prat, Laura Iogna
    Pallini, Giada
    Guerrero, Marta
    Buzzetti, Elena
    Saffioti, Francesca
    Arico, Francesco
    Mantovani, Anna
    Rosselli, Matteo
    Pinzani, Massimo
    Tsochatzis, Emmanuel
    JOURNAL OF HEPATOLOGY, 2020, 73 : S408 - S408
  • [3] ElastPQ shear-wave elastography compared to fibroscan transient elastography for fibrosis staging in patients with NAFLD
    Roccarina, D.
    Buzzetti, E.
    Misas, M. G.
    Rosselli, M.
    Majumdar, A.
    Pinzani, M.
    Tsochatzis, E.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S236 - S236
  • [4] Comparison of point shear wave elastography (ElastPQ-pSWE) and FibroScan Transient Elastography (F-TE) for liver fibrosis staging in patients with NAFLD
    Roccarina, Davide
    Prat, Laura Iogna
    Guerrero, Marta
    Buzzetti, Elena
    Saffioti, Francesca
    Arico', Francesco
    Mantovani, Anna
    Rosselli, Matteo
    Pinzani, Massimo
    Tsochatzis, Emmanuel
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E781 - E782
  • [5] Comparison of ElastPQ Shear-wave Elastography (ElastPQ-SWE) and FibroScan Transient Elastography (F-TE) for liver fibrosis staging in patients with NAFLD
    Roccarina, D.
    Prat, L. I.
    Guerrero, M.
    Buzzetti, E.
    Rosselli, M.
    Pinzani, M.
    Tsochatzis, E.
    JOURNAL OF HEPATOLOGY, 2018, 68 : S554 - S554
  • [6] Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD
    Argalia, Giulio
    Ventura, Claudio
    Tosi, Niccolo
    Campioni, Daniele
    Tagliati, Corrado
    Tufillaro, Marianna
    Cucco, Monica
    Baroni, Gianluca Svegliati
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2022, 127 (05): : 571 - 576
  • [7] Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD
    Giulio Argalia
    Claudio Ventura
    Niccolò Tosi
    Daniele Campioni
    Corrado Tagliati
    Marianna Tufillaro
    Monica Cucco
    Gianluca Svegliati Baroni
    Andrea Giovagnoni
    La radiologia medica, 2022, 127 : 571 - 576
  • [8] Point shear wave elastography and vibration controlled transient elastography for estimating liver fibrosis in a cohort of liver transplant patients
    Valente, G.
    Rinaldi, L.
    Moggio, G.
    Piai, G.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2020, 24 (13) : 7357 - 7365
  • [9] Diagnostic comparison of vibration-controlled transient elastography and MRI techniques in overweight and obese patients with NAFLD
    Asako Nogami
    Masato Yoneda
    Michihiro Iwaki
    Takashi Kobayashi
    Takaomi Kessoku
    Yasushi Honda
    Yuji Ogawa
    Kento Imajo
    Takuma Higurashi
    Kunihiro Hosono
    Hiroyuki Kirikoshi
    Satoru Saito
    Atsushi Nakajima
    Scientific Reports, 12
  • [10] Diagnostic comparison of vibration-controlled transient elastography and MRI techniques in overweight and obese patients with NAFLD
    Nogami, Asako
    Yoneda, Masato
    Iwaki, Michihiro
    Kobayashi, Takashi
    Kessoku, Takaomi
    Honda, Yasushi
    Ogawa, Yuji
    Imajo, Kento
    Higurashi, Takuma
    Hosono, Kunihiro
    Kirikoshi, Hiroyuki
    Saito, Satoru
    Nakajima, Atsushi
    SCIENTIFIC REPORTS, 2022, 12 (01)