Direct strength prediction of cold-formed steel fixed-ended singly-symmetric columns buckling in flexural-torsional modes

被引:2
|
作者
Cerqueira, Elisa [1 ]
Landesmann, Alexandre [1 ]
Camotim, Dinar [2 ]
Dinis, Pedro B. [2 ]
Martins, Andre D. [3 ]
机构
[1] Univ Fed Rio De Janeiro, Programa Engn Civil, PEC, COPPE,UFRJ, Rio De Janeiro, Brazil
[2] Univ Lisbon, CERIS, DECivil, Inst Super Tecn, Lisbon, Portugal
[3] Univ Lisbon, IDMEC, DEM, Inst Super Tecn, Lisbon, Portugal
关键词
CFS fixed-ended singly-symmetric columns; Flexural-torsional buckling; Flexural-torsional; flexural interaction; Shell finite element analysis; Flexural-torsional and interactive global; failures; Direct Strength Method (DSM) design; DESIGN;
D O I
10.1016/j.tws.2023.110730
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The work reported in this paper is a sequel of previous numerical investigations carried out by the authors on the post-buckling behaviour, strength and Direct Strength Method (DSM) design of cold-formed steel (CFS) fixed-ended plain and lipped channel columns (both singly-symmetric with respect to the major-axis) buckling in flexural-torsional modes and experiencing global-global interaction -a coupling phenomenon involving major-axis flexural-torsional (FMT) and minor-axis flexural (Fm) buckling that was first unveiled in those studies. In the specific context of plain and lipped channel columns, a DSM-based design approach for columns buckling in FMT modes and failing in either pure FMT or FMT-Fm interactive modes was developed and shown to provide accurate, mostly safe and reliable predictions of the experimental (only a few) and numerical failure loads available. The success of this research effort encouraged the authors to extend the scope of the investigation to fixed-ended columns with other singly-symmetric cross-section shapes, namely return-lip, web-stiffened and web/flange-stiffened lipped channels, hat-sections and rack-sections (deemed representative of any arbitrary singly-symmetric cross-section). The results attained during this investigation are presented and discussed in detail -they concern the post-buckling behaviour, strength and DSM-based design of the columns analysed, including fairly extensive failure load sets (ANsys non-linear shell finite element models are used to obtain them). The main output of this work is a DSM-based design approach for arbitrary CFS fixed-ended singly-symmetric columns exhibiting pure FMT or FMT-F-m interactive failures.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Flexural-torsional failure and DSM design of fixed-ended cold-formed steel columns at elevated temperatures
    Bicelli, Antonio Albuquerque
    Landesmann, Alexandre
    Camotim, Dinar
    Dinis, Pedro Borges
    THIN-WALLED STRUCTURES, 2021, 169
  • [2] Improved design rules for fixed ended cold-formed steel columns subject to flexural-torsional buckling
    Gunalan, Shanmuganathan
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2013, 73 : 1 - 17
  • [3] Torsional-flexural buckling of singly symmetric cold-formed steel beam columns
    Indian Inst of Technology, Tamil Nadu, India
    J Constr Steel Res, 1-3 (191-193):
  • [4] Flexural-torsional buckling of general cold-formed steel columns with unequal unbraced lengths
    Glauz, R. S.
    THIN-WALLED STRUCTURES, 2017, 119 : 946 - 955
  • [5] DSM-Based failure load prediction of CFS pin-ended singly symmetric columns buckling in flexural-torsional modes
    Cerqueira, Elisa
    Oliveira Jr, Carlos
    Landesmann, Alexandre
    Camotim, Dinar
    Dinis, Pedro B.
    Martins, Andre D.
    THIN-WALLED STRUCTURES, 2024, 204
  • [6] Tests and design of fixed-ended cold-formed steel plain angle columns
    Young, B
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (12) : 1931 - 1940
  • [7] Shape optimisation of singly-symmetric cold-formed steel purlins
    Guimara, V. M.
    Gilbert, B. P.
    Talebian, N.
    Wang, B.
    THIN-WALLED STRUCTURES, 2021, 161
  • [8] Shape optimisation of manufacturable and usable cold-formed steel singly-symmetric and open columns
    Wang, Bin
    Gibert, Benoit P.
    Guan, Hong
    Teh, Lip H.
    THIN-WALLED STRUCTURES, 2016, 109 : 271 - 284
  • [9] Design of fixed-ended cold-formed plain channel columns
    Young, B
    Rasmussen, KJR
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 145 - 150
  • [10] Flexural-torsional buckling behaviour and resistances of fixed-ended press-braked S690 high strength steel angle section columns
    Zhang, Lulu
    Liang, Yating
    Zhao, Ou
    ENGINEERING STRUCTURES, 2020, 223