Remote photoplethysmography for heart rate measurement: A review

被引:27
|
作者
Xiao, Hanguang [1 ]
Liu, Tianqi [1 ]
Sun, Yisha [2 ]
Li, Yulin [1 ]
Zhao, Shiyi [1 ]
Avolio, Alberto [3 ]
机构
[1] Chongqing Univ Technol, Sch Artificial Intelligence, Chongqing 401135, Peoples R China
[2] Chongqing Normal Univ, Sch Comp & Informat Sci, Chongqing 401331, Peoples R China
[3] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney 2019, Australia
关键词
Heart rate; Remote photoplethysmography; Non-contact; Deep learning; PULSE-RATE; LEARNING FRAMEWORK; OXYGEN-SATURATION; RESPIRATORY RATE; NONCONTACT; REPRESENTATION; PPG;
D O I
10.1016/j.bspc.2023.105608
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart rate (HR) ranks among the most critical physiological indicators in the human body, significantly illuminating an individual's state of physical health. Distinguished from traditional contact-based heart rate measurement, the utilization of Remote Photoplethysmography (rPPG) for remote heart rate monitoring eliminates the need for skin contact, relying solely on a camera for detection. This non-contact measurement method has emerged as an increasingly noteworthy research area. With the rapid development of deep learning, new technologies in this area have spurred the emergence of many new rPPG methods for HR measurement. However, comprehensive review papers in this field are scarce. Consequently, this paper aims to provide a comprehensive overview centered around rPPG methods employed for the purpose of heart rate measurement. We systematically organized the existing rPPG methods, with a specific focus on those based on deep learning, and described and analyzed the structures and key aspects of these methods. Additionally, we summarized the datasets and tools used for related research and compiled the performance of different methods on prominent datasets. Finally, this paper discusses the current research barriers in rPPG methods, as well as the latest practical applications and potential future directions for development. We hope that this review will help researchers quickly understand this field and promote the exploration of more unknown challenges.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Remote Photoplethysmography for Heart Rate and Blood Oxygenation Measurement: A Review
    Pirzada, Pireh
    Wilde, Adriana
    Harris-Birtill, David
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23436 - 23453
  • [2] Review on remote heart rate measurements using photoplethysmography
    Ru Jing Lee
    Saaveethya Sivakumar
    King Hann Lim
    Multimedia Tools and Applications, 2024, 83 : 44699 - 44728
  • [3] Review on remote heart rate measurements using photoplethysmography
    Lee, Ru Jing
    Sivakumar, Saaveethya
    Lim, King Hann
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 83 (15) : 44699 - 44728
  • [4] Automatic region-based heart rate measurement using remote photoplethysmography
    Kossack, Benjamin
    Wisotzky, Eric
    Hilsmann, Anna
    Eisert, Peter
    2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW 2021), 2021, : 2755 - 2759
  • [5] Measurement of Heart Rate Using Photoplethysmography
    Saquib, Nazmus
    Papon, Md Tarikul Islam
    Ahmad, Ishtiyaque
    Rahman, Ashikur
    2015 INTERNATIONAL CONFERENCE ON NETWORKING SYSTEMS AND SECURITY (NSYSS), 2015, : 158 - 163
  • [6] Remote photoplethysmography (rPPG) in the wild: Remote heart rate imaging via online webcams
    Di Lernia, Daniele
    Finotti, Gianluca
    Tsakiris, Manos
    Riva, Giuseppe
    Naber, Marnix
    BEHAVIOR RESEARCH METHODS, 2024, 56 (07) : 6904 - 6914
  • [7] Heart rate monitoring via remote photoplethysmography with motion artifacts reduction
    Cennini, Giovanni
    Arguel, Jeremie
    Aksit, Kaan
    van Leest, Arno
    OPTICS EXPRESS, 2010, 18 (05): : 4867 - 4875
  • [8] Non-Contact Remote Measurement of Heart Rate Variability using Near-Infrared Photoplethysmography Imaging
    Yu, Xinchi
    Paul, Michael
    Antink, Christoph Hoog
    Venema, Boudewijn
    Blazek, Vladimir
    Bollheimer, Cornelius
    Leonhardt, Steffen
    Teichmann, Daniel
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 846 - 849
  • [9] Is Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review
    Lazim, Md Rizman Md Lazin Md
    Aminuddin, Amilia
    Chellappan, Kalaivani
    Ugusman, Azizah
    Hamid, Adila A.
    Ahmad, Wan Amir Nizam Wan
    Mohamad, Mohd Shawal Faizal
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (07)
  • [10] Optimal color channel combination across skin tones for remote heart rate measurement in camera-based photoplethysmography
    Ernst, Hannes
    Scherpf, Matthieu
    Malberg, Hagen
    Schmidt, Martin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68