3D-printed helmet-type neuro-navigation approach (I-Helmet) for transcranial magnetic stimulation

被引:2
|
作者
Wang, He [1 ]
Cui, Dong [2 ,3 ]
Jin, Jingna [1 ]
Wang, Xin [1 ]
Li, Ying [1 ]
Liu, Zhipeng [1 ]
Yin, Tao [1 ,4 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Inst Biomed Engn, Tianjin, Peoples R China
[2] Shandong First Med Univ, Sch Radiol, Jinan, Shandong, Peoples R China
[3] Shandong Acad Med Sci, Jinan, Shandong, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Neurosci Ctr, Beijing, Peoples R China
关键词
transcranial magnetic stimulation (TMS); coil positioning; coil orientation; landmark guide; individualized positioning; helmet-type method; clinically friendly way; I-Helmet; REGISTRATION; SYSTEM; TMS;
D O I
10.3389/fnins.2023.1224800
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Neuro-navigation is a key technology to ensure the clinical efficacy of TMS. However, the neuro-navigation system based on positioning sensor is currently unable to be promoted and applied in clinical practice due to its time-consuming and high-cost. In the present study, we designed I-Helmet system to promote an individualized and clinically friendly neuro-navigation approach to TMS clinical application. I-Helmet system is based on C++ with a graphical user interface that allows users to design a 3D-printed helmet model for coil navigation. Besides, a dedicated coil positioning accuracy detection method was promoted based on three-dimensional (3D) printing and 3D laser scanning for evaluation. T1 images were collected from 24 subjects, and based on each image, phantom were created to simulate skin and hair. Six 3D-printed helmets with the head positioning hole enlarged by 0-5% tolerance in 1% increments were designed to evaluate the influences of skin, hair, and helmet-tolerance on the positioning accuracy and contact force of I-Helmet. Finally, I-Helmet system was evaluated by comparing its positioning accuracy with three skin hardnesses, three hair styles, three operators, and with or without landmarks. The accuracy of the proposed coil positioning accuracy detection method was about 0.30 mm in position and 0.22 degrees in orientation. Skin and hair had significant influences on positioning accuracy (p < 0.0001), whereas different skin hardnesses, hair styles, and operators did not (p > 0.05). The tolerance of the helmet presented significant influences on positioning accuracy (p < 0.0001) and contact force (p < 0.0001). The positioning accuracy significantly increased (p < 0.0001) with landmark guided I-Helmet. 3D-printed helmet-type Neuro-navigation approach (I-Helmet) with 3% tolerance and landmarks met the positioning requirements for TMS in clinical practice with less than 5 N mean contact force, 3-5 mm positioning accuracy, 65.7 s mean operation time, and 50-yuan material cost. All the results suggest that the cost of I-Helmet system may be much less than the that of training clinical doctors to position the coil of TMS operation during short period of time.
引用
收藏
页数:9
相关论文
共 19 条
  • [1] Individualized and clinically friendly helmet-type coil positioning method (I-Helmet) for transcranial magnetic stimulation
    Wang, He
    Jin, Jingna
    Wang, Xin
    Li, Ying
    Liao, Wenqing
    Cui, Dong
    Liu, Zhipeng
    Yin, Tao
    BRAIN STIMULATION, 2022, 15 (05) : 1023 - 1025
  • [2] Patient-specific 3D-printed helmet for post-craniectomy defect - a case report
    Pang, Sherby Suet-Ying
    Fang, Evan
    Chen, Kam Wai
    Leung, Matthew
    Chow, Velda Ling-Yu
    Fang, Christian
    3D PRINTING IN MEDICINE, 2022, 8 (01)
  • [3] Patient-specific 3D-printed helmet for post-craniectomy defect – a case report
    Sherby Suet-Ying Pang
    Evan Fang
    Kam Wai Chen
    Matthew Leung
    Velda Ling-Yu Chow
    Christian Fang
    3D Printing in Medicine, 8
  • [4] A 3D-Printed helmet for precise and repeatable neuromodulation targeting in awake non-human primates
    Tang, Chengjie
    Zhang, Wenlei
    Zhang, Xiaocheng
    Zhou, Jiahui
    Wang, Zijing
    Zhang, Xueze
    Wu, Xiaotian
    Su, Hang
    Jiang, Haifeng
    Zhai, Rongwei
    Zhao, Min
    HELIYON, 2024, 10 (17)
  • [5] Application of Virtual Reconstruction 3D-Printed External Fixation Helmet in Early Functional Treatment of Facial Fracture
    Ge W.
    Wang Y.
    Ge K.
    Wu J.
    Fan J.
    Yang T.
    Wang Q.
    Xu B.
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (03): : 368 - 371
  • [6] A 3D-Printed PLCL Scaffold Coated with Collagen Type I and Its Biocompatibility
    He, Yong
    Liu, Wei
    Guan, Lianxiong
    Chen, Jielin
    Duan, Li
    Jia, Zhaofeng
    Huang, Jianghong
    Li, Wencui
    Liu, Jianquan
    Xiong, Jianyi
    Liu, Lijun
    Wang, Daping
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [7] A new, open-source 3D-printed transcranial magnetic stimulation (TMS) coil tracker holder for double blind, sham-controlled neuronavigation studies
    Caulfield, Kevin A.
    Lopez, James W.
    Cox, Claire E.
    Roberts, Donna R.
    McTeague, Lisa M.
    BRAIN STIMULATION, 2020, 13 (03) : 600 - 602
  • [8] Comparison of different pinning techniques for 3D-printed radius with Salter-Harris type I fracture
    Kim, Tea-Hyung
    Kim, Hwi-Yool
    THAI JOURNAL OF VETERINARY MEDICINE, 2023, 53 (01): : 15 - 22
  • [9] Comparison of endoscopic type I tympanoplasty with and without assistance of customized 3D-printed guiding template for tympanic membrane
    Yang, Zifei
    Chen, Xiaoyun
    Ye, Fan
    Huang, Yideng
    Wu, Xianmin
    Wu, Cong
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2021, 42 (05)
  • [10] A 3D-printed coaxial microfluidic device approach for generating magnetic liquid metal droplets with large size controllability
    Xiaokang He
    Jie Wu
    Tao Hu
    Shouhu Xuan
    Xinglong Gong
    Microfluidics and Nanofluidics, 2020, 24