Numerical analysis of traditional Chinese timber structure: Simplified finite element model and composite elements of joints

被引:12
|
作者
Zhang, Baozhuang [1 ,3 ,4 ]
Xie, Qifang [1 ,2 ,3 ,4 ]
Li, Shengying [3 ]
Zhang, Lipeng [3 ]
Xue, Jianyang [3 ,4 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150080, Peoples R China
[2] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[4] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Shaanxi, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Traditional Chinese timber structure; Mortise-tenon joint; Column foot joint; Dou-gong joint; Simplified FE model; Composite elements; Hysteresis; Parametric analysis; Performance degradation; ROTATIONAL PERFORMANCE; SEMIRIGID CONNECTIONS; FRAMED STRUCTURES; SEISMIC BEHAVIOR; NUKI JOINTS; MECHANISM; MORTISE; DAMAGE; WOOD;
D O I
10.1016/j.jobe.2023.106027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mortise-tenon (M-T) joint, column foot joint, and Dou-Gong joint play a key role in the seismic behavior and energy dissipation of traditional timber structures. To simplify the modeling process and predict accurately the hysteretic behaviors of traditional timber joints as well as the global seismic responses of traditional timber structures, three types of composite elements, which were composed of varying non-linear one-dimensional spring elements available in the ANSYS finite element (FE) software, were proposed to characterize the hysteretic performance of the M-T joint, the column foot joint, and the Dou-Gong joint, respectively. The beam element was used for simulating the timber components with large size and not easily damaged. The parameters of the composite elements were identified from the simplified hysteretic model or test hysteretic curve of each type of joint. The simplified FE models of the M-T joint, M-T jointed timber frame, column foot joint, and Dou-Gong joint were developed, and verified using the cyclic loading tests of joints, respectively. Based on the validated composite elements and simplified FE models of varying joints, the three-dimensional simplified bar system FE model of a 1/3.52-scaled palace -style ancient timber structures was established using the ANSYS, and also validated using the shaking table tests, in terms of its dynamic characteristics and responses. Good agreements be-tween the model predictions and test results were observed. Additionally, parametric analyses were performed, while revealing and quantifying the effects of performance degradation for the M-T joint, column foot joint, and Dou-Gong joint on the dynamic responses to the structure. It is found that the damage to the Dou-Gong joint had little effect on the maximum story drift of column frame layer, however, the damage to the M-T joint and column foot joint would signif-icantly increase the maximum story drift of column frame layer. When the damage degree of the M-T joint, Dou-Gong joint, and column foot joint in the structure was up to 60%, the maximum story drift ratios of column frame layer were close to 1/48, 1/50, and 1/39, respectively, the maximum story drift ratios of Dou-Gong layer were approximately 1/164, 1/98, and 1/125, respectively.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Finite Element Model Updating of Riveted Joints of Simplified Model Aircraft Structure
    Yunus, M. A.
    Rani, M. N. Abdul
    Sani, M. S. M.
    Shah, M. A. S. Aziz
    INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, MATERIALS AND APPLIED SCIENCE, 2018, 1952
  • [2] Finite Element Analysis of Elastoplastic Elements in the Iwan Model of Bolted Joints
    Wang, Sheng-Ao
    Zhu, Min
    Xie, Xin
    Li, Biao
    Liang, Tian-Xi
    Shao, Zhao-Qun
    Liu, Yi-Long
    MATERIALS, 2022, 15 (17)
  • [3] Analysis of Composite Timber-Concrete Ceiling Structure by Finite Element Method
    Mikolasek, David
    Sucharda, Oldrich
    Brozovsky, Jiri
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 254 - 259
  • [4] FINITE ELEMENT ANALYSIS ON MECHANICAL BEHAVIOR OF COLUMN FOOT JOINT IN TRADITIONAL CHINESE TIMBER STRUCTURES
    Wang, Juan
    He, Junxiao
    Yang, Qingshan
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 1396 - 1402
  • [5] Elements of a Timber Lamella Structure: Analysis and Systematization of Joints
    Petrovic, Milica
    Pavicevic, Darko
    Ilic, Isidora
    Terzovic, Jefto
    Sekularac, Nenad
    BUILDINGS, 2023, 13 (04)
  • [6] FINITE-ELEMENT ANALYSIS OF GLUED TIMBER FINGER JOINTS
    MILNER, HR
    YEOH, E
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1991, 117 (03): : 755 - 766
  • [7] Simplified Analysis Research on Ancient Chinese Timber Structure
    Li, Wei
    Gao, Dafeng
    Cao, Pengnan
    Ding, Xinjian
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1831 - +
  • [8] A Mechanical Model Used for the Multifactor Analysis of Through-Tenon Joints in Traditional Chinese Timber Structures
    Pan, Yi
    An, Renbing
    You, Wenlong
    Fan, Yuanqing
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024, 18 (04) : 551 - 576
  • [9] Glued-in-rod timber joints: analytical model and finite element simulation
    A. Hassanieh
    H. R. Valipour
    M. A. Bradford
    R. Jockwer
    Materials and Structures, 2018, 51
  • [10] Glued-in-rod timber joints: analytical model and finite element simulation
    Hassanieh, A.
    Valipour, H. R.
    Bradford, M. A.
    Jockwer, R.
    MATERIALS AND STRUCTURES, 2018, 51 (03)