Experimental investigation on the R1234yf air conditioning system with a battery cooling loop under realistic conditions of electric vehicles

被引:0
|
作者
Guo, Bentao [1 ,2 ]
Zhao, Lanping [1 ,4 ]
Zhou, Jian [3 ]
Sun, Xudong [3 ]
Yang, Zhigang [2 ]
机构
[1] Tongji Univ, Inst Refrigerat & Cryogen Engn, Sch Mech Engn, Shanghai, Peoples R China
[2] Shanghai Key Lab Vehicle Aerodynam & Vehicle Therm, Shanghai, Peoples R China
[3] SAIC Motor Corp Ltd Passenger Vehicle Co, Shanghai, Peoples R China
[4] Tongji Univ, Inst Refrigerat & Cryogen Engn, Sch Mech Engn, 4800 Caoan Rd, Shanghai 200092, Peoples R China
关键词
Mobile air-conditioning (MAC); battery thermal load; medium to high load condition; R1234yf; optimal filling rate; system performance; DROP-IN REPLACEMENT; THERMAL MANAGEMENT-SYSTEM; ENERGY PERFORMANCE EVALUATION; LITHIUM-ION BATTERIES; REFRIGERANT R1234YF; EXERGY ANALYSIS; HEAT-EXCHANGER; R134A; EVAPORATOR; SIMULATION;
D O I
10.1177/09544070231156953
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The air-conditioning system of an electrical vehicle (EV) with a cooling loop for battery was experimentally investigated at medium to high load conditions, using R1234yf as refrigerant. Optimal filling rates of R1234yf and R134a were first determined as 975 g with the battery cooling loop closed. Then, the system performance regarding the two refrigerants with optimal charges was compared with various chiller thermal loads at maximum cabin cooling capacity condition as well as nine high load conditions. It was found that using R1234yf as the alternative of R134a, the HVAC cooling capacity, the power consumption of the compressor and the coefficient of performance (COP) decreased by 23.6%, 10.5%, and 8.1%, respectively, at maximum cooling capacity condition with a chiller load of 1.5 kW. At high load conditions with various chiller thermal loads, the reductions of HVAC cooling capacity and power consumption were 8.2%-29.8% and 3.2%-19%, respectively, resulting in a decrease in COP of 1%-16.3%. Thirdly, it was presented that, for R1234yf, at high vehicle speed conditions with the TXVs as original setting, the outlet air temperature of the HVAC box increased about 2.4 degrees C, with the power consumption increased by 17.3%, if the chiller thermal load was increased from 0 to 2.5 kW. Other main conclusion included that, at idle condition, for the R1234yf system with the chiller loop on, the outlet temperature of the HVAC box and COP decreased by 2.7 degrees C and 37.1%, respectively, when the compressor speed increased from 4000 to 7000 rpm.
引用
收藏
页码:1913 / 1930
页数:18
相关论文
共 50 条
  • [1] Experimental Study of an Air-Conditioning System in an Electric Vehicle with R1234yf
    Song, Jeonghyun
    Eom, Seongyong
    Lee, Jaeseung
    Chu, Youngshin
    Kim, Jaewon
    Choi, Seohyun
    Choi, Minsung
    Choi, Gyungmin
    Park, Yeseul
    [J]. ENERGIES, 2023, 16 (24)
  • [2] EXPERIMENTAL INVESTIGATION OF MOBILE AIR CONDITIONING SYSTEM PERFORMANCE WITH R1234YF AS WORKING FLUID
    Zhao, Yu
    Chen, Jiangping
    Xu, Baixing
    He, Bin
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1568 - +
  • [3] The refrigerant R1234yf in air conditioning systems
    Zilio, Claudio
    Brown, J. Steven
    Schiochet, Giovanni
    Cavallini, Alberto
    [J]. ENERGY, 2011, 36 (10) : 6110 - 6120
  • [4] Experimental investigation of the effects of compressor types on the performance of an automobile air conditioning system using R1234yf
    Alkan, Alpaslan
    Inan, Mehmet Sait
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 58 - 66
  • [5] Exergetic Investigation of a R1234yf Automotive Air Conditioning System with Internal Heat Exchanger
    Direk, M.
    Mert, M. S.
    Yuksel, F.
    Kelesoglu, A.
    [J]. INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2018, 21 (02) : 103 - 109
  • [6] Performance improvement potentials of R1234yf mobile air conditioning system
    Qi, Zhaogang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 : 35 - 40
  • [7] Performance of Automotive Air Conditioning System with R134a and R1234yf
    Kuwar, Yogendra Vasantrao
    Narasimham, G. S. V. L.
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2020, 28 (02)
  • [8] Experimental Performance Analysis of R1234yf in an Air-Conditioning System as Substitute of R134a
    Medany, M. M.
    El Morsi, M.
    El-Sayed, A. R.
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (04)
  • [9] Experimental Research and Optimization on the Environmental Friendly R1234yf Refrigerant in Automobile Air Conditioning System
    施骏业
    柳慈翀
    胡记超
    赵宇
    陈江平
    [J]. Journal of Shanghai Jiaotong University(Science), 2016, 21 (05) : 548 - 556
  • [10] Experimental research and optimization on the environmental friendly R1234yf refrigerant in automobile air conditioning system
    Shi J.
    Liu C.
    Hu J.
    Zhao Y.
    Chen J.
    [J]. Journal of Shanghai Jiaotong University (Science), 2016, 21 (5) : 548 - 556