Removal of Per- and Polyfluoroalkyl substances by anion exchange resins: Scale-up of rapid small-scale column test data

被引:4
|
作者
Cheng, Lan [1 ]
Knappe, Detlef R. U. [1 ]
机构
[1] North Carolina State Univ, Dept Civil Construct & Environm Engn, Campus Box 7908, Raleigh, NC 27695 USA
关键词
Drinking water treatment; Remediation; Perfluoroalkyl acids; Per- and polyfluoroalkyl ether acids; GRANULAR ACTIVATED CARBON; DRINKING-WATER; PERFLUOROALKYL SUBSTANCES; ADSORPTION TESTS; ION-EXCHANGE; DESIGN; PFASS;
D O I
10.1016/j.watres.2023.120956
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Anion exchange (IX) is a readily implementable water treatment method that can effectively remove per- and polyfluoroalkyl substances (PFAS). The overarching objective of this research was to predict PFAS removal in full-or pilot-scale packed-bed IX resin contactors from rapid small-scale column test (RSSCT) data. Specific objectives were to (1) assess the effects of IX resin crushing on total anion exchange capacity and packed bed density, (2) determine the effects of initial PFAS concentration on PFAS uptake capacity, (3) determine the rate-limiting step controlling PFAS uptake kinetics, (4) determine the effects of hydraulic loading rate on PFAS uptake capacity, and (5) link constant diffusivity RSSCT data to pilot test data to develop a scale-up protocol. Experiments were conducted with two single-use IX resins and three water matrices, including coagulated surface water and groundwater. Crushing IX resin did not substantially change the bed density and total anion exchange capacity, but the morphology of particles changed from almost perfectly spherical to irregularly shaped. PFAS uptake capacity was independent of influent PFAS concentrations in the 30-300 ng/L range. This finding facilitated the development of an RSSCT scale-up approach because influent PFAS concentrations in RSSCTs and corresponding pilot tests often differ. Biot number values and data from interrupted RSSCTs demonstrated that film diffusion or a combination of film diffusion and intraparticle diffusion controls the rate of PFAS uptake by IX resins. From RSSCTs with identical empty bed contact times but different hydraulic loading rates (v(f)), PFAS uptake capacity was found to be a function of the square root of the product of Sherwood number and particle shape factor (root Sh x phi). Using a constant diffusivity RSSCT design with a reduced v(f), full-or pilot-scale PFAS breakthrough data can therefore be predicted by multiplying the bed volumes of water treated in the RSSCT by a factor of root(Sh(pilot) x phi(pilot))/(Sh(RSSCT) x phi(RSSCT)). This research will support the design of future IX treatment processes in the context of PFAS remediation and drinking water treatment.
引用
收藏
页数:10
相关论文
共 39 条
  • [1] Removal of Per- and Polyfluoroalkyl substances by anion exchange resins: Scale-up of rapid small-scale column test data
    Cheng, Lan
    Knappe, Detlef R.U.
    Water Research, 2024, 249
  • [2] Assessing explicit models of per- and polyfluoroalkyl substances adsorption on anion exchange resins by rapid small-scale column tests
    Wang, Yifei
    Warner, Max
    Li, Ke
    Hawkins, Gary L.
    Huang, Qingguo
    CHEMOSPHERE, 2022, 300
  • [3] Predicting per- and polyfluoroalkyl substances removal in pilot-scale granular activated carbon adsorbers from rapid small-scale column tests
    Hopkins, Zachary R.
    Knappe, Detlef R. U.
    AWWA WATER SCIENCE, 2024, 6 (02):
  • [4] Remove legacy perfluoroalkyl acids and emerging per- and polyfluoroalkyl ether acids by single-use and regenerable anion exchange resins: Rapid small-scale column tests and model fits
    Liu, Bingchuan
    Liu, Yen -Ling
    Sun, Mei
    WATER RESEARCH, 2024, 257
  • [5] Removal of per- and polyfluoroalkyl substances from contaminated groundwater by granular activated carbon and anion exchange resins: a pilot-scale comparative assessment
    Liu, Charlie J.
    Murray, Conner C.
    Marshall, R. Eric
    Strathmann, Timothy J.
    Bellona, Christopher
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2022, 8 (10) : 2245 - 2253
  • [6] Avoiding pitfalls when modeling removal of per- and polyfluoroalkyl substances by anion exchange
    Haupert, Levi M.
    Pressman, Jonathan G.
    Speth, Thomas F.
    Wahman, David G.
    AWWA WATER SCIENCE, 2021, 3 (02):
  • [7] Anion exchange resin removal of per- and polyfluoroalkyl substances (PFAS) from impacted water: A critical review
    Boyer, Treavor H.
    Fang, Yida
    Ellis, Anderson
    Dietz, Rebecca
    Choi, Youn Jeong
    Schaefer, Charles E.
    Higgins, Christopher P.
    Strathmann, Timothy J.
    WATER RESEARCH, 2021, 200
  • [8] Pilot-scale comparison of granular activated carbons, ion exchange, and alternative adsorbents for per- and polyfluoroalkyl substances removal
    Medina, Ricardo
    Pannu, Manmeet W.
    Grieco, Scott A.
    Hwang, Michael
    Pham, Christine
    Plumlee, Megan H.
    AWWA WATER SCIENCE, 2022, 4 (05):
  • [9] Insights into the Understanding of Adsorption Behaviors of Legacy and Emerging Per- and Polyfluoroalkyl Substances (PFASs) on Various Anion-Exchange Resins
    Tan, Hong-Ming
    Pan, Chang-Gui
    Yin, Chao
    Yu, Kefu
    TOXICS, 2023, 11 (02)
  • [10] Assessing Rapid Small-Scale Column Tests for Treatment of Perfluoroalkyl Acids by Anion Exchange Resin
    Schaefer, Charles E.
    Nguyen, Dung
    Ho, Paul
    Im, Jihyon
    LeBlanc, Alan
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (22) : 9701 - 9706