Leveraging coagulation mechanisms to reduce fouling and increase natural organic matter removal during coagulation/flocculation-ultrafiltration treatment

被引:2
|
作者
Malkoske, Tyler A. [1 ]
Berube, Pierre R. [1 ,2 ]
Andrews, Robert C. [1 ]
机构
[1] Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON M5S 1A4, Canada
[2] Univ British Columbia, Dept Civil Engn, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Coagulation mechanisms; Ultrafiltration; Rapid mixing; Flocculation; Natural organic matter; MEMBRANE FILTRATION; FLOC PROPERTIES; UF MEMBRANE; WATER; PRETREATMENT; PERFORMANCE; SIZE; FLOCCULATION; PERMEABILITY; OPTIMIZATION;
D O I
10.1016/j.seppur.2023.124877
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Despite widespread application of coagulation/flocculation prior to ultrafiltration (UF), a lack of knowledge remains regarding the appropriate selection of conditions to reduce fouling and/or improve the removal of natural organic matter (NOM). The present study investigates the impact of conditions (alum dosage, pH) associated with specific coagulation mechanisms along with two different coagulation/flocculation configurations, on UF performance in terms of fouling and NOM removal. In-line coagulation/flocculation configurations were provided at bench-scale under continuous-flow conditions, which enabled quantification of hydraulically reversible/irreversible fouling over multiple permeation cycles. When compared to raw water without the addition of coagulant, utilization of coagulation/flocculation generally increased hydraulically irreversible fouling resistance. Conditions that promote adsorption destabilization (2.5 mg/L alum, pH 5.5) substantially reduced or eliminated the hydraulically irreversible accumulation of NOM, likely by minimizing interactions between certain NOM components (e.g. biopolymers and humic substances) and the membrane surface. When considering conditions that promote combined (8 mg/L alum, pH 7.5) and sweep (15 mg/L alum, pH 7) mechanisms, inclusion of flocculation increased TOC removal while reducing total/hydraulically irreversible fouling resistance (when compared to coagulation alone), despite greater amounts of NOM being retained by the membrane. The reduced fouling resistance was likely due to the formation of larger floc which formed a more permeable foulant layer. Results from the present study suggest that if only fouling control is required, conditions that promote adsorption destabilization are optimal, whereas if NOM removal is required, conditions that promote sweep are optimal. Inclusion of flocculation provided an optimal trade-off between fouling reduction and NOM removal for both adsorption destabilization and sweep, which should be considered during the design of coagulation/flocculation-UF systems to reduce operating costs despite potentially higher construction costs when compared to coagulation alone.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Coagulation/flocculation/ultrafiltration for natural organic matter removal in drinking water production
    Costa, AR
    de Pinho, MN
    [J]. 4TH WORLD WATER CONGRESS: INNOVATION IN DRINKING WATER TREATMENT, 2004, 4 (5-6): : 215 - 222
  • [2] Effect of organic matter on arsenic removal during coagulation/flocculation treatment
    Pallier, Virginie
    Feuillade-Cathalifaud, Genevieve
    Serpaud, Bernard
    Bollinger, Jean-Claude
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2010, 342 (01) : 26 - 32
  • [3] Pretreatment strategies for mitigation of membrane fouling by effluent organic matter in ultrafiltration: ozonation and coagulation/flocculation
    Kim, Geon-Youb
    Kim, Ji-Hoon
    Kim, Min-Gue
    Kim, Hyung-Soo
    Kim, Hyung-Sook
    Chang, Won-Seok
    [J]. DESALINATION AND WATER TREATMENT, 2017, 77 : 177 - 184
  • [4] Photocatalysis-coagulation to control ultrafiltration membrane fouling caused by natural organic matter
    Wang, Nan
    Li, Xing
    Yang, Yanling
    Zhou, Zhiwei
    Shang, Yi
    Zhuang, Xiaoxuan
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 265
  • [5] Coagulation/submerged hollow-fibre ultrafiltration for natural organic matter removal
    Machenbach, I
    Leiknes, T
    Odegaard, H
    [J]. MEMBRANES IN DRINKING AND INDUSTRIAL WATER PRODUCTION III, 2003, : 401 - 407
  • [6] Natural organic matter removal by coagulation during drinking water treatment: A review
    Matilainen, Anu
    Vepsalainen, Mikko
    Sillanpaa, Mika
    [J]. ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2010, 159 (02) : 189 - 197
  • [7] The fouling of ultrafiltration membranes by natural organic matter after chemical coagulation treatment with different initial mixing conditions
    Kim, H. C.
    Hong, J. H.
    Lee, S.
    [J]. 5TH WORLD WATER CONGRESS: DRINKING WATER QUALITY AND TREATMENT, 2006, 6 (04): : 117 - 124
  • [8] Assessment of Coagulation-Flocculation Process Efficiency for the Natural Organic Matter Removal in Drinking Water Treatment
    Musteret, Corina Petronela
    Morosanu, Irina
    Ciobanu, Ramona
    Plavan, Oana
    Gherghel, Andreea
    Al-Refai, Malek
    Roman, Ioana
    Teodosiu, Carmen
    [J]. WATER, 2021, 13 (21)
  • [9] Removal of natural organic matter and trihalomethane minimization by coagulation/flocculation/filtration using a natural tannin
    Bongiovani, Milene Carvalho
    Camacho, Franciele Pereira
    Coldebella, Priscila Ferri
    Valverde, Karina Cardoso
    Nishi, Leticia
    Bergamasco, Rosangela
    [J]. DESALINATION AND WATER TREATMENT, 2016, 57 (12) : 5406 - 5415
  • [10] Effects of coagulation on submerged ultrafiltration membrane fouling caused by particles and natural organic matter (NOM)
    Li YongHong
    Wang Jun
    Zhang Wei
    Zhang XiaoJian
    Chen Chao
    [J]. CHINESE SCIENCE BULLETIN, 2011, 56 (06): : 584 - 590