Hemodynamic and Mid-Term Outcomes for Transcatheter Aortic Valve Replacement in Degenerated Internally Stented Valves

被引:3
|
作者
AlBadri, Ahmed [1 ]
Joseph, Jubin [1 ]
Patel, Vivek [1 ]
Patel, Dhairya [1 ]
Koren, Ofir [1 ]
Cheng, Wen [1 ]
Jilaihawi, Hasan [1 ]
Makkar, Raj [1 ]
机构
[1] Cedars Sinai Med Ctr, Smidt Heart Inst, 127 S San Vicente Blvd,Suite A3600, Los Angeles, CA 90048 USA
关键词
KEY WORDS coronary obstruction; internally stented valves; Mitroflow; outcome; TAVR; Trifecta; LONG-TERM OUTCOMES; CORONARY OBSTRUCTION; CLINICAL-OUTCOMES; IMPLANTATION; DURABILITY; MITROFLOW; TRIFECTA; INSIGHTS; BIOPROSTHESES; PERFORMANCE;
D O I
10.1016/j.jcin.2023.01.381
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Valve-in-valve (ViV) transcatheter aortic valve replacement is indicated in patients undergoing repeat intervention for degenerative aortic valve bioprostheses. Patients with internally stented valves (ie, Mitroflow and Trifecta) are at high risk for coronary artery obstruction during ViV procedures because of valve design, as the leaflets are mounted outside the valve stent.OBJECTIVES The aim of this study was to compare the hemodynamic and clinical outcomes of transcatheter aortic valve replacement within internally stented valves (ViV-IS) vs other surgical valves (ViV-OS).METHODS Baseline characteristics, hemodynamic parameters, and clinical outcomes of patients who underwent ViV-IS were retrospectively collected and compared with those of patients who underwent ViV-OS.RESULTS A total of 250 patients (65% men, median Society of Thoracic Surgeons score 4.4% [IQR: 2.2%-8.4%]) were included. Seventy-one patients (28%) underwent ViV-IS, and 179 (72%) patients underwent ViV-OS. Patients who un-derwent ViV-OS had better periprocedural hemodynamic status compared with those who underwent ViV-IS (median mean gradient 6 [IQR: 2-13] vs 12 [IQR: 6-16]; P < 0.001). This was not significantly different when both groups were matched on the basis of age, sex, and valve internal diameter size (median mean gradient: 18 [IQR: 13-25] for ViV-OS vs 18 [IQR: 11-24] for ViV-IS; P = 0.36). Coronary protection for potential occlusion was performed more in ViV-IS vs ViV-OS pr (79% vs 6%, respectively; P < 0.001). Patients who underwent ViV-IS had a higher risk for coronary occlusion, requiring stent deployment, compared with those who underwent ViV-OS (54% vs 3%, respectively; P < 0.001. There was no difference in mortality at 3 years between the 2 groups (P = 0.59). CONCLUSIONS Patients who underwent ViV-IS had a very high incidence of coronary compromise that can be safely and effectively treated. In the setting of a systematic coronary protection strategy, ViV-OS and ViV-IS provide similar mid-term outcome, and periprocedural hemodynamic status (following adjustment for age, sex, and true internal diameter). (J Am Coll Cardiol Intv 2023;16:542-554) (c) 2023 by the American College of Cardiology Foundation.
引用
收藏
页码:542 / 554
页数:13
相关论文
共 50 条
  • [1] Hemodynamic and Mortality Outcome for Transcatheter Valve in Degenerated Internally Stented Surgical Valves Compared With Other Degenerated Surgical Valves
    AlBadri, Ahmed
    Joseph, Jubin
    Jilaihawi, Hasan
    Patel, Vivek
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B213 - B213
  • [2] Mid-Term Outcomes of Valve-in-Valve Transcatheter Aortic Valve Replacement
    Kliner, Dustin
    Yousef, Sarah
    Toma, Catalin
    Serna-Gallegos, Derek
    West, David
    Makani, Amber
    Wang, Yisi
    Thoma, Floyd
    Sultan, Ibrahim
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S88 - S88
  • [3] Usefulness of the Transcatheter Aortic Valve Replacement Risk Score to Determine Mid-Term Outcomes
    Saji, Mike
    Tobaru, Tetsuya
    Higuchi, Ryosuke
    Mahara, Keitaro
    Takamisawa, Itaru
    Iguchi, Nobuo
    Doi, Shinichiro
    Okazaki, Shinya
    Tamura, Harutoshi
    Takanashi, Shuichiro
    Takayama, Morimasa
    Isobe, Mitsuaki
    CIRCULATION JOURNAL, 2019, 83 (08) : 1755 - 1761
  • [4] Transcatheter Aortic Valve Replacement for Degenerated Transcatheter Aortic Valves The TRANSIT International Project
    Testa, Luca
    Agnifili, Mauro
    Van Mieghem, Nicolas M.
    Tchetche, Didier
    Asgar, Anita W.
    De Backer, Ole
    Latib, Azeem
    Reimers, Bernhard
    Stefanini, Giulio
    Trani, Carlo
    Colombo, Antonio
    Giannini, Francesco
    Bartorelli, Antonio
    Wojakowski, Wojtek
    Dabrowski, Maciej
    Jagielak, Dariusz
    Banning, Adrian P.
    Kharbanda, Rajesh
    Moreno, Raul
    Schofer, Joachim
    van Royen, Niels
    Pinto, Duane
    Serra, Antoni
    Segev, Amit
    Giordano, Arturo
    Brambilla, Nedy
    Popolo Rubbio, Antonio
    Casenghi, Matteo
    Oreglia, Jacopo
    De Marco, Federico
    Tanja, Rudolph
    McCabe, James M.
    Abizaid, Alexander
    Voskuil, Michiel
    Teles, Rui
    Biondi Zoccai, Giuseppe
    Bianchi, Giovanni
    Sondergaard, Lars
    Bedogni, Francesco
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (06) : 628 - 638
  • [5] Commentary: Mid-term outcomes in a real-world transcatheter aortic valve replacement population
    Eikelboom, Rachel
    Spooner, Aaron J.
    Yamashita, Michael H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 165 (04): : 1357 - 1358
  • [6] Comparison of periprocedural and mid-term stroke rates and outcomes between surgical aortic valve replacement and transcatheter aortic valve replacement patients
    Aalaei-Andabili, Seyed Hossein
    Anderson, R. David
    Petersen, John W.
    Beaver, Thomas M.
    Bavry, Anthony A.
    Klodell, Charles T.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (04): : 591 - 597
  • [7] Impact of small annulus on valve hemodynamic and mid-term outcome following transcatheter aortic valve implantation compared with surgical aortic valve replacement
    Kamioka, N.
    Shirai, S.
    Arita, T.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1158 - 1158
  • [8] Mid-Term Outcomes of Transcatheter Aortic Valve Replacement in Extremely Large Annuli With Edwards SAPIEN 3 Valve
    Sengupta, Aditya
    Zaid, Syed
    Kamioka, Norihiko
    Terre, Juan
    Miyasaka, Masaki
    Hirji, Sameer A.
    Hensey, Mark
    Geloo, Nadim
    Petrossian, George
    Robinson, Newell
    Sarin, Eric
    Ryan, Liam
    Yoon, Sung-Han
    Tan, Christina W.
    Khalique, Omar K.
    Kodali, Susheel K.
    Kaneko, Tsuyoshi
    Shah, Pinak B.
    Wong, Chiu
    Salemi, Arash
    Sharma, Kapil
    Kozina, Joseph A.
    Szerlip, Molly A.
    Don, Creighton W.
    Gafoor, Sameer
    Zhang, Ming
    Newhart, Zachary
    Kapadia, Samir R.
    Mick, Stephanie L.
    Krishnaswamy, Amar
    Kini, Annapooma
    Ahmad, Hasan
    Lansman, Steven L.
    Mack, Michael J.
    Webb, John G.
    Babaliaros, Vasilis
    Thourani, Vinod H.
    Makkar, Raj R.
    Leon, Martin B.
    George, Isaac
    Tang, Gilbert H. L.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (02) : 210 - 216
  • [9] Mid-term hemodynamic and clinical results of the stented porcine Medtronic Mosaic valve in aortic position
    Botzenhardt, F
    Gansera, B
    Kemkes, BM
    THORACIC AND CARDIOVASCULAR SURGEON, 2004, 52 (01): : 34 - 41
  • [10] Reoperative Surgical Aortic Valve Replacement Versus Transcatheter Valve-in-Valve Replacement for Degenerated Bioprosthetic Aortic Valves
    Ejiofor, Julius I.
    Yammine, Maroun
    Harloff, Morgan T.
    McGurk, Siobhan
    Muehlschlegel, Jochen D.
    Shekar, Prem S.
    Cohn, Lawrence H.
    Shah, Pinak
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2016, 102 (05): : 1452 - 1458