IMU positioning affects range of motion measurement during squat motion analysis

被引:3
|
作者
Blandeau, Mathias [1 ]
Guichard, Romain [1 ]
Hubaut, Remy [1 ]
Leteneur, Sebastien [1 ]
机构
[1] Univ Polytech Hauts de France, CNRS, UMR LAMIH 8201, F-59313 Valenciennes, France
关键词
Inertial measurement units; Squat; Positioning; ADJUSTMENTS; VALIDATION; MOVEMENTS;
D O I
10.1016/j.jbiomech.2023.111598
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Inertial Measurement Units (IMUs) provides embedded and accessible (financially and technically speaking) motion analysis for sports or clinical applications (rehabilitation, therapy...). Despite being advertised for it ease of use, the very nature of IMU sensor makes it prone to errors which are usually corrected through calibration processes thus adding extra complexity for the users. The main goal of this study is to estimate the effect of sensor positioning on the thigh for a simple assessment of squat motion range of motion (ROM) as could be done in a pragmatic clinical approach (i.e., without prior calibration). Kinematics, squat counts and timing of three IMU sensors along the thigh were recorded during squat motion and compared to an optoelectronic reference system. Results showed concordance coefficients of the IMU system over 0.944 without the need for calibration with a preference for placement on the distal part of the segment regarding kinematics data.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] EFFECTS OF CHANGING FROM FULL RANGE OF MOTION TO PARTIAL RANGE OF MOTION ON SQUAT KINETICS
    Drinkwater, Eric J.
    Moore, Norman R.
    Bird, Stephen P.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2012, 26 (04) : 890 - 896
  • [2] Acetabular Positioning to Maximize Range of Motion
    D'Antonio, J. A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 131 - 132
  • [3] Lower Extremity Strength and the Range of Motion in Relation to Squat Depth
    Kim, Si-Hyun
    Kwon, Oh-Yun
    Park, Kyue-Nam
    Jeon, In-Cheol
    Weon, Jong-Hyuck
    JOURNAL OF HUMAN KINETICS, 2015, 45 (01) : 59 - 69
  • [4] Measurement of the range of motion in joints
    Silver, D
    JOURNAL OF BONE AND JOINT SURGERY, 1923, 5 : 569 - 578
  • [5] The Measurement and Analysis of Chinese Adults' Range of Motion Joint
    Zhou, Qianxiang
    Jin, Yu
    Liu, Zhongqi
    DIGITAL HUMAN MODELING AND APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS AND RISK MANAGEMENT. HUMAN BODY, MOTION AND BEHAVIOR, DHM 2021, PT I, 2021, 12777 : 163 - 177
  • [6] Assessments of Ground Reaction Force and Range of Motion in Terms of Fatigue during the Body Weight Squat
    Erman, Berkant
    Ozkol, Mehmet Zeki
    Ivanovic, Jelena
    Arslan, Hakan
    Cosic, Marko
    Yuzbasioglu, Yasin
    Dopsaj, Milivoj
    Aksit, Tolga
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (08)
  • [7] IMU Sensor Module for the Measurement of High-speed Motion in the Analysis of Human Skills
    Kuwahara, Takashi
    Kawamoto, Hiroaki
    Sankai, Yoshiyuki
    2019 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2019, : 560 - 565
  • [8] Computer analysis of PCL fibres during range of motion
    Zaffagnini, S
    Martelli, S
    Garcia, L
    Visani, A
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (05) : 420 - 428
  • [9] Computer analysis of PCL fibres during range of motion
    Stefano Zaffagnini
    Sandra Martelli
    Leopoldo Garcia
    Andrea Visani
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 420 - 428
  • [10] Cervical Spine Range of Motion Measurement Utilizing Image Analysis
    Matsuo, Kana
    Fujita, Koji
    Koyama, Takafumi
    Morishita, Shingo
    Sugiura, Yuta
    PROCEEDINGS OF THE 17TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS (VISAPP), VOL 4, 2022, : 861 - 867