Magnetic Field Analysis and Measurement of Pulsed Septum Magnet

被引:0
|
作者
Tong, Jin [1 ]
Liu, Yongfang [1 ]
机构
[1] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201204, Peoples R China
基金
中国国家自然科学基金;
关键词
Diffraction limited storage ring (DLSR); eddy current; injection and extraction; magnetic field simulation; septum thermal;
D O I
10.13052/2023.ACES.J.380917
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional off -axis injection becomes inadequate in diffraction limited storage ring (DLSR) for its small dynamic aperture (DA). On -axis injection with thin septum could solve the problem. This paper focuses on the theoretical calculation, field simulation, and measurement of thin septum magnets. The scheme of eddycurrent type thin septum magnets (the thinnest portion is with the thickness of 0.9 mm) was adopted with laminated silicon steel sheets as the magnet core. The simulation of main field, stray field along the beam trajectory, the leakage field decayed over 1 millisecond time was carried out within Opera 2D/3D. Field measurement and analysis of thin septum magnets also has been conducted comprehensively. The results meet requirements, and the work laid a foundation for injection technology of an advanced light source.
引用
收藏
页码:751 / 755
页数:5
相关论文
共 50 条
  • [1] Pulsed Wire Magnetic-Field Measurement System on Permanent Magnet Quadrupoles
    Chen, Chih Wei
    Chang, C. S.
    Chen, Hsiung
    Chu, Yun-Liang
    Lin, Fu-Yuen
    Yang, Chin-Kang
    Huang, Jui-Che
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 4
  • [2] Analysis of directionality for pulsed magnetic field measurement sensor
    Su Yang
    Wang Jiang-ping
    Zhang Yong-zhi
    Li Yu-quan
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 127 - 130
  • [3] Optimization design and measurement of septum magnet with low leakage field
    Wei, Yanqun
    Zhang, Jingjing
    Hu, Qiang
    Ma, Lizhen
    Yao, Zeen
    Yang, Jing
    Jin, Lian
    Yao, Qinggao
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2024, 75 (04) : 445 - 457
  • [4] A PULSED SEPTUM MAGNET FOR THE FERMILAB ANTIPROTON SOURCE
    SATTI, JA
    HOLMES, SD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 3628 - 3630
  • [5] Influence of pulsed magnet design on the magnetic field characteristics
    Safonchik, MO
    Shakhov, MA
    Parfeniev, RV
    SIXTH CRYOGENICS 2000, PROCEEDINGS, 2000, (06): : 96 - 96
  • [6] MEASUREMENT OF THE MAGNETIC-FIELD OF THE CDF MAGNET
    NEWMANHOLMES, C
    SCHMIDT, EE
    YAMADA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (03): : 443 - 451
  • [7] PRECISION INSITU MEASUREMENT OF INDUCTANCE AND RESISTANCE OF A PULSED FIELD MAGNET
    HARRISON, N
    MEESON, P
    PROBST, PA
    SPRINGFORD, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (02) : 148 - 152
  • [8] Measurement and analysis of the pulsed magnetic field phase lag in the ceramic case
    Wang, XQ
    Feng, DR
    Shang, L
    Pei, YJ
    He, N
    Zhao, T
    ACTA PHYSICA SINICA, 2004, 53 (12) : 4319 - 4324
  • [9] INEXPENSIVE PULSED POWER-SUPPLY FOR A SEPTUM MAGNET
    PRAEG, WF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (02): : 190 - 190
  • [10] PULSED SEPTUM MAGNET FOR EXTRACTION FROM FERMILAB BOOSTER
    COSGROVE, DF
    JOHNSON, RP
    SNOWDON, SC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (03) : 1263 - 1265