Electrochemical chromium removal using nanodiamond enhanced flow-through electrosorption

被引:10
|
作者
Shin, Yong-Uk [1 ]
Pan, Weiyi [1 ]
Patel, Sohum K. [1 ]
Lim, Jihun [2 ]
Winter, Lea R. [1 ]
Ma, Wen [1 ]
Hong, Seungkwan [2 ]
Elimelech, Menachem [1 ]
机构
[1] Yale Univ, Dept Chem & Environm Engn, New Haven, CT 06520 USA
[2] Korea Univ, Sch Civil Environm & Architectural Engn, Seoul 136701, South Korea
基金
美国国家科学基金会;
关键词
Flow-through redox -assist electrosorption; Graphitized nanodiamond; Hexavalent chromium Cr (VI); Trivalent chromium Cr (III); CAPACITIVE DEIONIZATION; ION-EXCHANGE; WASTE-WATER; ELECTRODES; CR(VI); ADSORPTION; REDUCTION; PERFORMANCE; MECHANISM; OXIDATION;
D O I
10.1016/j.cej.2023.145756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective removal of hexavalent chromium (Cr(VI)) from water is challenging due to the need for a highly selective process. Efficient chromium removal may potentially be achieved through the use of redox-assisted flowthrough electrosorption. In this study, graphitized nanodiamonds (NDs) were annealed under various conditions and the ND with the lowest internal resistance was applied to an activated carbon cloth electrode. The NDmodified electrode was then used as the cathode in a flow-through electrode cell with pristine carbon cloth as the anode. Effective chromium removal was found through a dual pathway mechanism, whereby Cr(VI) is directly electrosorbed at the anode while Cr(VI) is reduced to Cr(III) at the cathode, and subsequently precipitated as Cr(OH)(3 )under the locally high cathodic pH conditions. The effects of flow rate and charging/discharging voltage on Cr(VI) removal were further investigated, revealing that sufficiently low flow rates (i.e., <= 1 mL min(-1)) are required for effective Cr(OH)(3) precipitation and sufficiently high (i.e., >1.4 V) reverse voltages are needed during the discharging period to enable full desorption. Overall, the system displayed high Cr removal capacity (i.e., up to 39.51 mu mol g-1) and favorable redox of Cr(VI) to trivalent chromium Cr(III) and Cr(III) to Cr (VI). These results suggest that the ND-modified electrode is a promising tool for the removal of toxic metal ions from wastewater.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Simulation of hexavalent chromium removal by electrocoagulation using iron anode in flow-through reactor
    Hojabri, Shayan
    Rajic, Ljiljana
    Zhao, Yuwei
    Alshawabkeh, Akram N.
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 476
  • [2] ELECTROSORPTION OF ORGANICS ON FLOW-THROUGH POROUS-ELECTRODES
    ALKIRE, RC
    EISINGER, RS
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1981, 128 (03) : C72 - C72
  • [3] A continuous flow-through system with integration of electrosorption and peroxi-coagulation for efficient removal of organics
    Yang, Weilu
    Zhou, Minghua
    Ma, Liang
    CHEMOSPHERE, 2021, 274
  • [4] Flow-through electrochemical removal of benzotriazole by electroactive ceramic membrane
    Wang, Shengli
    Pei, Shuzhao
    Zhang, Jinna
    Huang, Junqiang
    You, Shijie
    WATER RESEARCH, 2022, 218
  • [5] THE REMOVAL OF DISSOLVED SULFIDE FROM GEOTHERMAL FLUIDS USING A FLOW-THROUGH ELECTROCHEMICAL REACTOR
    MCKUBRE, MCH
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (08) : C334 - C334
  • [6] ELECTROCHEMICAL REMOVAL OF SILVER IONS FROM PHOTOGRAPHIC FIXING SOLUTIONS USING A POROUS FLOW-THROUGH ELECTRODE
    VANZEE, J
    NEWMAN, J
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1977, 124 (05) : 706 - 708
  • [7] Electrochemical removal of sulfide on porous carbon-based flow-through electrodes
    Sergienko, Natalia
    Irtem, Erdem
    Gutierrez, Oriol
    Radjenovic, Jelena
    JOURNAL OF HAZARDOUS MATERIALS, 2019, 375 (19-25) : 19 - 25
  • [8] ELECTROCHEMICAL DETECTOR FOR FLOW-THROUGH ANALYSES
    GILGEN, P
    RACH, P
    CHIMIA, 1978, 32 (09) : 345 - 350
  • [9] Enhanced mechanism of carbamazepine degradation by electrochemical activation of persulfate in flow-through system
    Cai, Jingju
    Xie, Jinxin
    Xing, Liping
    Zhou, Lean
    Zhang, Qizhan
    Zhou, Minghua
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 301
  • [10] Electrochemical Hydrogen Peroxide Generation and Activation Using a Dual-Cathode Flow-Through Treatment System: Enhanced Selectivity for Contaminant Removal by Electrostatic Repulsion
    Duan, Yanghua
    Sedlak, David L.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (31) : 14042 - 14051