Rapid detection and quality evaluation of Shuang-Huang-Lian injection by ATR-IR and NIR spectroscopy combined with chemometrics

被引:7
|
作者
Ju, Ying [1 ]
Yin, Chunling [1 ]
Zhang, Yan [1 ]
Meng, Xiangru [1 ]
Zhao, Liuchuang [1 ]
Hu, Leqian [1 ]
机构
[1] Henan Univ Technol, Sch Chem & Chem Engn, Zhengzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Shuang-Huang-Lian Injection; Spectral techniques; Rapid quantitative analysis; Quality evaluation; Chemometrics; INFRARED-SPECTROSCOPY;
D O I
10.1016/j.saa.2022.122008
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Quality evaluation and consistency evaluation of drugs are the keys to ensure the therapeutic effect and safety of drugs. In this study, attenuated total refraction infrared (ATR-IR) spectroscopy and near-infrared (NIR) spec-troscopy combined with chemometrics were used for rapid detection and quality evaluation of active compo-nents of Shuang-Huang-Lian injection (SHLI), a traditional Chinese medicine preparation commonly used in China. Taking the chromatographic detection results as a reference, the partial least squares (PLS) model based on ATR-IR and NIR data was constructed by removing the bands with serious noise interference and low signal frequency band. The results showed that the PLS model achieved satisfactory results for the prediction of the three active components (chlorogenic acid, baicalin and phillyrin) in SHLI, indicating that the two spectral techniques combined with the PLS regression method could be successfully used for rapid quantitative analysis of the three active ingredients in SHLI. Relatively, the PLS model based on the ATR-IR spectrum has higher R2 and smaller RMSE than it based on the NIR spectrum. Furthermore, based on the rapid quantitative analysis of the three active ingredients in SHLI, the quality of 140 SHLI samples from seven manufacturers was evaluated by TOPSIS (technique for order preference by similarity to the ideal solution) analysis, and the consistency of different batches of SHLI products from the same manufacturer was evaluated. The results showed that there were differences in the quality of SHLI produced by different manufacturers, and the quality of different batches of SHLI produced by the same manufacturer was not completely consistent. In conclusion, ATR-IR and NIR spectroscopy combined with chemometrics can be used for accurate and rapid quantitative analysis and quality evaluation of SHLI. This study provides a good idea for the rapid quantitative analysis and quality evaluation of drugs or food based on spectroscopic technology and chemometrics.
引用
下载
收藏
页数:9
相关论文
共 26 条
  • [1] In Situ ATR-IR Spectroscopy Combined with Chemometrics for the Analysis of a Polymer Membrane
    Morita, Shigeaki
    BUNSEKI KAGAKU, 2018, 67 (04) : 179 - 186
  • [2] Development of an LC-MS method for determination of three active constituents of Shuang-huang-lian injection in rat plasma and its application to the drug interaction study of Shuang-huang-lian freeze-dried powder combined with levofloxacin injection
    Ye, Jing
    Song, Xiaowei
    Liu, Zhihong
    Zhao, Xu
    Geng, Lulu
    Bi, Kaishun
    Chen, Xiaohui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 898 : 130 - 135
  • [3] Rapid and comprehensive quality evaluation of Huang-qin from different origins by FT-IR and NIR spectroscopy combined with chemometrics
    Lv, Kaidi
    Yin, Chunling
    Li, Fang
    Chen, Wenbo
    Zhao, Liuchuang
    Liu, Zhimin
    Hu, Leqian
    PHYTOCHEMICAL ANALYSIS, 2024, : 1587 - 1599
  • [4] Combination of multi-model statistical analysis and quantitative fingerprinting in quality evaluation of Shuang-huang-lian oral liquid
    Si, Wei
    Qiao, Yali
    Liu, Zhe
    Jin, Gaowa
    Liu, Yanfang
    Xue, Xingya
    Zhou, Han
    Liu, Yanming
    Shen, Aijin
    Liang, Xinmiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7073 - 7083
  • [5] Rapid evaluation of quality parameters in plant products applying ATR-IR and Raman spectroscopy
    Schulz, H.
    Baranska, M.
    PROCEEDINGS OF THE IVTH INTERNATIONAL CONFERENCE ON MANAGING QUALITY IN CHAINS, VOLS 1 AND 2: THE INTEGRATED VIEW ON FRUITS AND VEGETABLES QUALITY, 2006, (712): : 347 - +
  • [6] Rapid evaluation and quantitative analysis of thyme, origano and chamomile essential oils by ATR-IR and NIR spectroscopy
    Schulz, H
    Quilitzsch, R
    Krüger, H
    JOURNAL OF MOLECULAR STRUCTURE, 2003, 661 : 299 - 306
  • [7] Combination of multi-model statistical analysis and quantitative fingerprinting in quality evaluation of Shuang-huang-lian oral liquid
    Wei Si
    Yali Qiao
    Zhe Liu
    Gaowa Jin
    Yanfang Liu
    Xingya Xue
    Han Zhou
    Yanming Liu
    Aijin Shen
    Xinmiao Liang
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7073 - 7083
  • [8] Correction to: Combination of multi-model statistical analysis and quantitative fingerprinting in quality evaluation of Shuang-huang-lian oral liquid
    Wei Si
    Yali Qiao
    Zhe Liu
    Gaowa Jin
    Yanfang Liu
    Xingya Xue
    Han Zhou
    Yanming Liu
    Aijin Shen
    Xinmiao Liang
    Analytical and Bioanalytical Chemistry, 2020, 412 : 8223 - 8223
  • [9] Rapid determination of baicalin and total baicalein content in Scutellariae radix by ATR-IR and NIR spectroscopy
    Navarro Escamilla, M.
    Rodenas Sanz, F.
    Li, H.
    Schoenbichler, S. A.
    Yang, B.
    Bonn, G. K.
    Huck, C. W.
    TALANTA, 2013, 114 : 304 - 310
  • [10] Rapid and non-destructive determination of the echinacoside content in Echinacea roots by ATR-IR and NIR spectroscopy
    Schulz, H
    Pfeffer, S
    Quilitzsch, R
    Steuer, B
    Reif, K
    PLANTA MEDICA, 2002, 68 (10) : 926 - 929